| Literature DB >> 35355112 |
Dominic Ku1,2, Bridget Copson3, Mark Fiorentino4, Jean-Marc Gerrard5,6, Stephen O'Leary5,6.
Abstract
SETTING: The Eustachian tube plays a vital role in middle ear physiology. There has been evidence that Eustachian tube (ET) and angle are correlated with middle ear function. The measurements of these Eustachian tube features are now made possible with computed tomography and multiplanar reconstruction techniques. However, there has not been a standardised protocol devised to these measurements in limited window cone-beam CT scans of temporal bones.Entities:
Keywords: Auditory tube; Cholesteatoma; Eustachian tube; Middle ear dysfunction; Otology; Radiology
Mesh:
Year: 2022 PMID: 35355112 PMCID: PMC9474359 DOI: 10.1007/s00405-022-07345-3
Source DB: PubMed Journal: Eur Arch Otorhinolaryngol ISSN: 0937-4477 Impact factor: 3.236
Summary of Eustachian tube measurements in the literature
| Author | Imaging modality | Anatomy measured | Method |
|---|---|---|---|
Takasaki 2007 [ | CT temporal bone (CT PTB) | ET length and angle | The length of the ET was defined as the distance from the pharyngeal orifice to the tympanic orifice (definitions in main text) |
| Angle of the ET was defined as the angle of a straight line representing the length of the ET against Reid’s standard plane | |||
|
| |||
| Dinç 2015 [ | CT PTB | ET length and angle | Used basal turns of cochlears as reference point (black arrows) and Frankfort line to adjust AP axis. Landmarks as defined in Takasaki et al |
|
| |||
Falkenberg-Jensen 2018 [ | CT PTB | Cartilaginous portion of ET length | Coronal reformats of 2 points on a single CT image were made, projecting 1) cranial limit (bony eminence separating carotid canal from bony ET) and caudal limit (tip of the soft tissue lip of the torus tubarius) |
|
| |||
Ha 2019 [ | Cone beam CT and CT PTB | Patulous ET length | Multiple points on the ET were traced on consecutive axial CT slides from the nasopharynx to the bony ET The images were reconstructed by the axis of the two points and the distance measured |
|
|
Fig. 1Development of the Ku-Copson plane on MPR analysis of CT PTB scans. A The right infraorbital margin (left arrow), right mandibular fossa (right arrow) and the upper margin of the right EAC are on the same plane. B The plane is adjusted to course through bilateral upper margins of EACs. C The right pharyngeal orifice (right arrow) and tympanic orifice (left arrow) are identified, the distance measured, and ET angle measured with reference to the mandibular fossa plane. D The left ET length and angle were measured
ET measurements with reference to Reid’s standard plane on CT sinus scans
| Measurements, | Mean (SD) | |
|---|---|---|
| Right ET angle, 30 | 32.8° (5.6) | 0.83 |
| Left ET angle, 30 | 33.1° (5.1) | |
| Right ET length, 30 | 32.5 mm (5.0) | 0.84 |
| Left ET length, 30 | 32.7 mm (5.0) | |
| Male, 48 vs Female, 12 | 33.2 (5.1) vs 30.3 (3.1) mm | 0.07 |
Comparison of ET measurements measured with reference to Reid’s standard plane (RSP) vs Ku-Copson plane
| Measurements, | Mean (SD) | |
|---|---|---|
| RSP ET angle, 60 | 33.0° (5.3) | 0.07 |
| MFP ET angle, 60 | 34.7° (5.2) | |
| RSP ET length, 60 | 32.6 mm (4.9) | 0.10 |
| MFP ET length, 60 | 31.3 mm (3.7) | |
| Male, 48 | ||
| RSP ET length | 33.2 mm (5.1) | 0.10 |
| MFP ET length | 31.7 mm (3.8) | |
| Female | ||
| RSP ET length | 30.3 mm (3.1) | 0.71 |
| MFP ET length | 29.8 mm (3.1) |
Comparison of ET measurements with reference to Ku-Copson plane in cohort in cone-beam CT (CBCT) vs in cohort with sinus CT scans
| Measurements, | Mean (SD) | |
|---|---|---|
| CBCT ET angle, 60 | 33.0° (6.1) | 0.11 |
| Sinus CT ET angle, 60 | 34.7° (5.2) | |
| CBCT ET length, 60 | 31.3 mm (3.7) | 0.26 |
| Sinus CT ET length, 60 | 31.9 mm (2.4) |
Comparison of patient demographics in cohort with cochlear implant (CI) vs in cohort with cholesteatoma (CH)
| Patient demographics | Mean (SD)/ | |
|---|---|---|
| Age in years | ||
| Cochlear implant | 63.9 (21.3) | 0.0001 |
| Cholesteatoma | 42.5 (14.3) | |
| Number of females | ||
| Cochlear implant | 14 (46.7%) | 0.43 |
| Cholesteatoma | 10 (33.3%) | |
| Number born in Australia | ||
| Cochlear implant | 22 (73.3%) | 0.064 |
| Cholesteatoma | 14 (46.7%) |
Comparison of ET measurements with reference to Ku-Copson plane in cohort with cochlear implant (CI) vs in cohort with cholesteatoma (CH)
| Measurements, | Mean (SD) | |
|---|---|---|
| Cochlear implant ET angle, 60 | 33.0° (6.1) | 0.0001 |
| Cholesteatoma ET angle, 60 | 27.8° (5.1) | |
| Cochlear implant ET length, 60 | 31.9 mm (2.4) | 0.0001 |