Hsiao-Pei Mok1, Lingzhu Wen1, Xiaoyi Lin1, Xin Lin1, Ning Liao2, Guochun Zhang3. 1. Department of Breast Cancer, Guangdong Provincial People's Hospital and Guangdong Academy of Medical Sciences, No. 106, Zhongshan 2 Road, Guangzhou, 510120, Guangdong, China. 2. Department of Breast Cancer, Guangdong Provincial People's Hospital and Guangdong Academy of Medical Sciences, No. 106, Zhongshan 2 Road, Guangzhou, 510120, Guangdong, China. syliaoning@scut.edu.cn. 3. Department of Breast Cancer, Guangdong Provincial People's Hospital and Guangdong Academy of Medical Sciences, No. 106, Zhongshan 2 Road, Guangzhou, 510120, Guangdong, China. guochun.zhang@hotmail.com.
Abstract
BACKGROUND: Subpectoral implant-based breast reconstruction following mastectomy commonly severs the inferior border of the pectoralis major muscle for better projection of the lower pole. This can affect a patient's postoperative motor function and result in animation deformity. Implant-based breast reconstruction using partial muscle coverage with an acellular dermal matrix (ADM) can be costly. There is an unmet clinical need for a novel surgical method for submuscular implant-based breast reconstruction. METHODS: We describe an innovative technique for submuscular implant-based breast reconstruction following mastectomy. The approach utilizes the serratus anterior muscle fascia connected to the lateral margin of the pectoralis major muscle to form a lateral tissue pocket for implant coverage. This method preserves the inferior border of the pectoralis major muscle and minimizes the size of ADM coverage. Patient satisfaction on the BREAST-Q Reconstruction Module and complications were assessed 12 months after surgery. RESULTS: The novel surgical design was safe and used minimal ADM (6 × 5cm2). Mean satisfaction with breasts was 61 ± 4.7 (range, 48-73), mean psychosocial well-being was 66 ± 10 (range, 50-93), and mean sexual well-being was 47 ± 7.8 (range, 27-70). Animation deformity was avoided by preserving the inferior border of the pectoralis major muscle. Rates of revision (7.6%) and postsurgical seroma (3.4%) were low, and capsular contracture was minimal. CONCLUSIONS: Submuscular implant-based breast reconstruction following mastectomy utilizing the serratus anterior muscle fascia connected to the lateral margin of the pectoralis major muscle to form a lateral tissue pocket for implant coverage is safe, feasible, and generates good aesthetic outcomes.
BACKGROUND: Subpectoral implant-based breast reconstruction following mastectomy commonly severs the inferior border of the pectoralis major muscle for better projection of the lower pole. This can affect a patient's postoperative motor function and result in animation deformity. Implant-based breast reconstruction using partial muscle coverage with an acellular dermal matrix (ADM) can be costly. There is an unmet clinical need for a novel surgical method for submuscular implant-based breast reconstruction. METHODS: We describe an innovative technique for submuscular implant-based breast reconstruction following mastectomy. The approach utilizes the serratus anterior muscle fascia connected to the lateral margin of the pectoralis major muscle to form a lateral tissue pocket for implant coverage. This method preserves the inferior border of the pectoralis major muscle and minimizes the size of ADM coverage. Patient satisfaction on the BREAST-Q Reconstruction Module and complications were assessed 12 months after surgery. RESULTS: The novel surgical design was safe and used minimal ADM (6 × 5cm2). Mean satisfaction with breasts was 61 ± 4.7 (range, 48-73), mean psychosocial well-being was 66 ± 10 (range, 50-93), and mean sexual well-being was 47 ± 7.8 (range, 27-70). Animation deformity was avoided by preserving the inferior border of the pectoralis major muscle. Rates of revision (7.6%) and postsurgical seroma (3.4%) were low, and capsular contracture was minimal. CONCLUSIONS: Submuscular implant-based breast reconstruction following mastectomy utilizing the serratus anterior muscle fascia connected to the lateral margin of the pectoralis major muscle to form a lateral tissue pocket for implant coverage is safe, feasible, and generates good aesthetic outcomes.