Keunbada Son1, Young-Tak Son1,2, Myoung-Uk Jin3, Kyu-Bok Lee1,4.
Abstract
This study aimed to survey users' satisfaction with a dental unit chair in order to highlight the elements affecting the dentist's satisfaction. The questionnaire items were drawn up with seven components that constitute a dental unit chair, including the light, patient seat, foot controller, water fountain and cuspidor, monitor, bracket table and controller, and dentist chair. With these questionnaire elements, a pilot experiment was conducted to test the reliability, and reliability analysis was conducted. The scale reliability was checked using Cronbach's alpha coefficient. Bartlett's test of sphericity, the Kaiser-Meyer-Olkin (KMO) measure, and factor analysis were performed to test whether the items would constitute appropriate questionnaire items for the survey. The survey was conducted with 26 dentists with more than three years of clinical experience. A correlation analysis was conducted using Pearson's correlation coefficient (PCC) (α = 0.05) to analyze the impact of the factors on the overall satisfaction with the dental unit chair. The items that were strongly correlated with the overall satisfaction score of the dental unit chair were the design and appearance quality of the dental unit chair (PCC = 0.781), its maintenance (PCC = 0.784), and the overall satisfaction with the water fountain and cuspidor (PCC = 0.703) (p < 0.05). Most of the questionnaire items could affect the overall satisfaction with the dental unit chair. Additionally, because the design and appearance quality, maintenance, and overall satisfaction with the water fountain and cuspidor may have the greatest impact on the overall satisfaction with the dental unit chair, the improvement of these elements may bring about the enhancement of the overall satisfaction.Entities:
Keywords: dental unit chair; dentist; design; satisfaction factor; survey
Year: 2022 PMID: 35326915 PMCID: PMC8950680 DOI: 10.3390/healthcare10030437
Source DB: PubMed Journal: Healthcare (Basel) ISSN: 2227-9032
Figure 1Dental unit chair system. (a) Light, (b) patient seat, (c) foot controller, (d) water fountain and cuspidor, (e) monitor, and (f) bracket table and controller.
User satisfaction questionnaire items.
| Components of the Dental Unit Chair | Environmental Factors | Clinical Needs |
|---|---|---|
| Light | Convenience of light head movement | Convenience of movement for accurate light irradiation into the patient’s oral cavity and operator’s comfort |
| Convenience of color temperature control | Color temperature control in consideration of tooth color discrimination and eye fatigue in various clinical environments | |
| Influence of illuminance | Illuminance suitable for treatment considering eye fatigue and resin light curing | |
| Patient seat | Appropriate length and area for each part | A seat that has a size suitable for the human body in Korea considering the patient and dentist’s body shape |
| Back reclining angle | Optimal backrest reclining angle for patient comfort and dentist posture | |
| Headrest recline angle | Optimal headrest reclining angle for patient comfort and dentist posture | |
| Backrest reclining speed | Appropriate speed considering both stability and convenience of operation when laying down or returning the patient to the original position | |
| Backrest seat thickness | Seat thickness considering the shape of the spine and knee height for the dentist’s correct treatment posture and patient comfort | |
| Convenience of auxiliary handle | Convenience that can help without interfering with the patient’s movement | |
| Foot controller | Ease of operation | Dentist’s intuitive operation convenience |
| Pedal pressure during operation | Precise use of the handpiece and less pressure on the ankle | |
| Water fountain and cuspidor | Ease of operation | Convenience of operation by patients and medical assistants |
| The height and area of the cuspidor | Height and area to minimize discomfort during movement | |
| Cup position | The position of the cup considering the convenience of the patient | |
| Water purification and wastewater treatment facilities | Pleasant environment and facilities to prevent cross infection | |
| Water quantity and speed | Adequacy of water supply quantity and water supply speed | |
| Convenience of cleaning the cuspidor | Automatic cleaning of contaminants and ease of cleaning management | |
| Monitor | Screen size | Visual convenience, various information provision, and monitor size in harmony with the overall medical system |
| Distance between monitor and operator/patient | Monitor distance considering visual convenience and movement for dentists and patients | |
| Convenience to move | Stable and smooth movement | |
| Resolution | Readability of radiographs, oral photographs, and text | |
| Arm support | Even after the monitor is moved, it is fixed by supporting the monitor stably without movement | |
| Bracket table and controller | Size | It is a size that can mount various instruments and does not affect the medical environment |
| Weight | Weight that is stable and does not burden when moving | |
| Mounting stability | Stable and convenient mounting of various instruments | |
| Controller user interface | User interface suitable for the user environment of dentists and medical assistants | |
| Stability of table arm operation | Stability when moving and fixing the table | |
| Dentist chair | Backrest angle and shape | Backrest angle and shape for dentists’ health and comfort |
| Convenience to move | Soft chair movement considering durability and noise | |
| Human engineering design | Design that harmonizes with the human body and does not burden the dentist, especially with long-term use |
Results of the factor analysis and reliability analysis for the extracted questionnaire items.
| Number | Items | Factor Analysis | Cronbach’s Alpha | |||
|---|---|---|---|---|---|---|
| Factor Load | Communality | Contribution Rate (%) | ||||
| 1 | Overall evaluation | Price | 0.782 | 0.797 | 51.504 | 0.881 |
| 2 | Versatility of function | 0.557 | 0.929 | |||
| 3 | Design and appearance quality | 0.561 | 0.926 | |||
| 4 | Maintenance | 0.682 | 0.815 | |||
| 5 | Overall satisfaction | 0.63 | 0.9 | |||
| 6 | Light | Convenience of light head movement | 0.819 | 0.878 | 9.055 | 0.859 |
| 7 | Convenience of color temperature control | 0.851 | 0.757 | |||
| 8 | Influence of illuminance | 0.829 | 0.959 | |||
| 9 | Overall satisfaction of light | 0.688 | 0.948 | |||
| 10 | Patient seat | Appropriate length and area for each part | 0.634 | 0.841 | 6.848 | 0.898 |
| 11 | Back reclining angle | 0.84 | 0.832 | |||
| 12 | Head rest recline angle | 0.572 | 0.744 | |||
| 13 | Backrest reclining speed | 0.726 | 0.746 | |||
| 14 | Backrest seat thickness | 0.578 | 0.91 | |||
| 15 | Convenience of auxiliary handle | 0.727 | 0.921 | |||
| 16 | Overall satisfaction of patient seat | 0.512 | 0.853 | |||
| 17 | Foot controller | Ease of operation | 0.506 | 0.936 | 6.191 | 0.886 |
| 18 | Pedal pressure during operation | 0.784 | 0.891 | |||
| 19 | Overall satisfaction of foot controller | 0.758 | 0.896 | |||
| 20 | Water fountain and cuspidor | Ease of operation | 0.688 | 0.934 | 4.596 | 0.938 |
| 21 | The height and area of the cuspidor | 0.608 | 0.937 | |||
| 22 | Cup position | 0.596 | 0.939 | |||
| 23 | Water purification and wastewater treatment facilities | 0.794 | 0.866 | |||
| 24 | Water quantity and speed | 0.65 | 0.853 | |||
| 25 | Convenience of cleaning the cuspidor | 0.828 | 0.942 | |||
| 26 | Overall satisfaction of water fountain and cuspidor | 0.759 | 0.915 | |||
| 27 | Monitor | Screen size | 0.845 | 0.943 | 3.43 | 0.963 |
| 28 | Distance between monitor and operator/patient | 0.886 | 0.892 | |||
| 29 | Convenience to move | 0.807 | 0.89 | |||
| 30 | Resolution | 0.57 | 0.807 | |||
| 31 | Arm support | 0.851 | 0.808 | |||
| 32 | Overall satisfaction of monitor | 0.64 | 0.836 | |||
| 33 | Bracket table and controller | Size | 0.839 | 0.814 | 3.29 | 0.974 |
| 34 | Weight | 0.872 | 0.848 | |||
| 35 | Mounting stability | 0.819 | 0.877 | |||
| 36 | Controller user interface | 0.624 | 0.918 | |||
| 37 | Stability of table arm operation | 0.559 | 0.905 | |||
| 38 | Overall satisfaction of bracket table and controller | 0.862 | 0.779 | |||
| 39 | Dentist chair | Back rest angle and shape | 0.789 | 0.801 | 2.303 | 0.93 |
| 40 | Convenience to move | 0.88 | 0.874 | |||
| 41 | Human engineering design | 0.518 | 0.939 | |||
| 42 | Overall satisfaction of dentist chair | 0.717 | 0.836 | |||
Study inclusion and exclusion criteria.
| Inclusion Criteria | Exclusion Criteria |
|---|---|
|
Clinical experience >3 years. Participants who have sufficient experience in using the dental unit chair system. Participants who fully understand the purpose of this clinical study and can participate actively. |
Participants who are inappropriate to participate in clinical trials in the judgment of the clinical trial director because they may affect the clinical trial results. Participants who have no experience in using a dental unit chair system. |
Results of the correlation analysis between the overall satisfaction score of the chair unit and the questionnaire items.
| Number | Items | Overall Satisfaction Score | ||
|---|---|---|---|---|
| Correlation Coefficient |
| |||
| 1 | Overall evaluation | Price | 0.648 | <0.001 * |
| 2 | Versatility of function | 0.64 | <0.001 * | |
| 3 | Design and appearance quality | 0.781 | <0.001 * | |
| 4 | Maintenance | 0.784 | <0.001 * | |
| 5 | Light | Convenience of light head movement | 0.568 | 0.002 * |
| 6 | Convenience of color temperature control | 0.426 | 0.03 * | |
| 7 | Influence of illuminance | 0.634 | 0.001 * | |
| 8 | Overall satisfaction of light | 0.629 | 0.001 * | |
| 9 | Patient seat | Appropriate length and area for each part | 0.403 | 0.041 * |
| 10 | Back reclining angle | 0.498 | 0.01 * | |
| 11 | Head rest recline angle | 0.361 | 0.07 | |
| 12 | Backrest reclining speed | 0.401 | 0.042 * | |
| 13 | Backrest seat thickness | 0.405 | 0.04 * | |
| 14 | Convenience of auxiliary handle | 0.504 | 0.009 * | |
| 15 | Overall satisfaction of patient seat | 0.587 | 0.002 * | |
| 16 | Foot controller | Ease of operation | 0.679 | <0.001 * |
| 17 | Pedal pressure during operation | 0.645 | <0.001 * | |
| 18 | Overall satisfaction of foot controller | 0.581 | 0.002 * | |
| 19 | Water fountain and cuspidor | Ease of operation | 0.633 | 0.001 * |
| 20 | The height and area of the cuspidor | 0.562 | 0.003 * | |
| 21 | Cup position | 0.609 | <0.001 * | |
| 22 | Water purification and wastewater treatment facilities | 0.608 | 0.001 * | |
| 23 | Water quantity and speed | 0.67 | <0.001 * | |
| 24 | Convenience of cleaning the cuspidor | 0.598 | 0.001 * | |
| 25 | Overall satisfaction of water fountain and cuspidor | 0.703 | <0.001 * | |
| 26 | Monitor | Screen size | 0.508 | 0.008 * |
| 27 | Distance between monitor and operator/patient | 0.492 | 0.011 * | |
| 28 | Convenience to move | 0.449 | 0.021 * | |
| 29 | Resolution | 0.563 | 0.003 * | |
| 30 | Arm support | 0.555 | 0.003 * | |
| 31 | Overall satisfaction of monitor | 0.545 | 0.004 * | |
| 32 | Bracket table and controller | Size | 0.576 | 0.002 * |
| 33 | Weight | 0.587 | 0.002 * | |
| 34 | Mounting stability | 0.627 | 0.001 * | |
| 35 | Controller user interface | 0.442 | 0.024 * | |
| 36 | Stability of table arm operation | 0.579 | 0.002 * | |
| 37 | Overall satisfaction of bracket table and controller | 0.564 | 0.003 * | |
| 38 | Dentist chair | Backrest angle and shape | 0.45 | 0.021 * |
| 39 | Convenience to move | 0.517 | 0.007 * | |
| 40 | Human engineering design | 0.354 | 0.076 | |
| 41 | Overall satisfaction of dentist chair | 0.369 | 0.064 | |
* Significance determined using Pearson’s correlation analysis, p < 0.05.
Results of the correlation analysis between the overall satisfaction of each element constituting the chair unit and the questionnaire items.
| Number | Items | Overall Satisfaction Score | ||
|---|---|---|---|---|
| Correlation Coefficient |
| |||
| 1 | Light | Convenience of light head movement | 0.369 | 0.064 |
| 2 | Convenience of color temperature control | 0.866 | <0.001 * | |
| 3 | Influence of illuminance | 0.803 | <0.001 * | |
| 4 | Patient seat | Appropriate length and area for each part | 0.821 | <0.001 * |
| 5 | Back reclining angle | 0.727 | <0.001 * | |
| 6 | Headrest recline angle | 0.436 | 0.026 * | |
| 7 | Back rest reclining speed | 0.700 | <0.001 * | |
| 8 | Back rest seat thickness | 0.643 | <0.001 * | |
| 9 | Convenience of auxiliary handle | 0.700 | <0.001 * | |
| 10 | Foot controller | Ease of operation | 0.736 | <0.001 * |
| 11 | Pedal pressure during operation | 0.737 | <0.001 * | |
| 12 | Water fountain and cuspidor | Ease of operation | 0.748 | <0.001 * |
| 13 | The height and area of the cuspidor | 0.824 | <0.001 * | |
| 14 | Cup position | 0.862 | <0.001 * | |
| 15 | Water purification and wastewater treatment facilities | 0.722 | <0.001 * | |
| 16 | Water quantity and speed | 0.686 | <0.001 * | |
| 17 | Convenience of cleaning the cuspidor | 0.774 | <0.001 * | |
| 18 | Monitor | Screen size | 0.871 | <0.001 * |
| 19 | Distance between monitor and operator/patient | 0.923 | <0.001 * | |
| 20 | Convenience to move | 0.877 | <0.001 * | |
| 21 | Resolution | 0.811 | <0.001 * | |
| 22 | Arm support | 0.865 | <0.001 * | |
| 23 | Bracket table and controller | Size | 0.824 | <0.001 * |
| 24 | Weight | 0.948 | <0.001 * | |
| 25 | Mounting stability | 0.899 | <0.001 * | |
| 26 | Controller user interface | 0.836 | <0.001 * | |
| 27 | Stability of table arm operation | 0.899 | <0.001 * | |
| 28 | Dentist chair | Back rest angle and shape | 0.768 | <0.001 * |
| 29 | Convenience to move | 0.780 | <0.001 * | |
| 30 | Human engineering design | 0.932 | <0.001 * | |
* Significance determined using Pearson’s correlation analysis, p < 0.05.