Literature DB >> 35312837

"Virtual" attenuation correction: improving stress myocardial perfusion SPECT imaging using deep learning.

Edward P Ficaro1,2, Venkatesh L Murthy2, Tomoe Hagio3, Alexis Poitrasson-Rivière1, Jonathan B Moody1, Jennifer M Renaud1, Liliana Arida-Moody2, Ravi V Shah4.   

Abstract

PURPOSE: Myocardial perfusion imaging (MPI) using single-photon emission computed tomography (SPECT) is widely used for coronary artery disease (CAD) evaluation. Although attenuation correction is recommended to diminish image artifacts and improve diagnostic accuracy, approximately 3/4ths of clinical MPI worldwide remains non-attenuation-corrected (NAC). In this work, we propose a novel deep learning (DL) algorithm to provide "virtual" DL attenuation-corrected (DLAC) perfusion polar maps solely from NAC data without concurrent computed tomography (CT) imaging or additional scans.
METHODS: SPECT MPI studies (N = 11,532) with paired NAC and CTAC images were retrospectively identified. A convolutional neural network-based DL algorithm was developed and trained on half of the population to predict DLAC polar maps from NAC polar maps. Total perfusion deficit (TPD) was evaluated for all polar maps. TPDs from NAC and DLAC polar maps were compared to CTAC TPDs in linear regression analysis. Moreover, receiver-operating characteristic analysis was performed on NAC, CTAC, and DLAC TPDs to predict obstructive CAD as diagnosed from invasive coronary angiography.
RESULTS: DLAC TPDs exhibited significantly improved linear correlation (p < 0.001) with CTAC (R2 = 0.85) compared to NAC vs. CTAC (R2 = 0.68). The diagnostic performance of TPD was also improved with DLAC compared to NAC with an area under the curve (AUC) of 0.827 vs. 0.780 (p = 0.012) with no statistically significant difference between AUC for CTAC and DLAC. At 88% sensitivity, specificity was improved by 18.9% for DLAC and 25.6% for CTAC.
CONCLUSIONS: The proposed DL algorithm provided attenuation correction comparable to CTAC without the need for additional scans. Compared to conventional NAC perfusion imaging, DLAC significantly improved diagnostic accuracy.
© 2022. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

Entities:  

Keywords:  Attenuation correction; Deep learning; MPI; Myocardial perfusion; Quantification; SPECT

Mesh:

Year:  2022        PMID: 35312837     DOI: 10.1007/s00259-022-05735-7

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   10.057


  2 in total

1.  2022 Artificial intelligence primer for the nuclear cardiologist.

Authors:  Manish Motwani
Journal:  J Nucl Cardiol       Date:  2022-07-19       Impact factor: 3.872

Review 2.  2022 ASNC/AAPM/SCCT/SNMMI guideline for the use of CT in hybrid nuclear/CT cardiac imaging.

Authors:  Mouaz H Al-Mallah; Timothy M Bateman; Kelley R Branch; Andrew Crean; Eric L Gingold; Randall C Thompson; Sarah E McKenney; Edward J Miller; Venkatesh L Murthy; Koen Nieman; Todd C Villines; Michael V Yester; Andrew J Einstein; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2022-09-02       Impact factor: 3.872

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.