Ryan B Morales1, Christopher T DeGroot2, Grant C Scholes3, Jason I Gerhard1. 1. Department of Civil and Environmental Engineering, The University of Western Ontario, London, ON, Canada. 2. Department of Mechanical and Materials Engineering, The University of Western Ontario, London, ON, Canada. 3. Savron, Guelph, ON, Canada.
Abstract
STARx (Self-sustaining Treatment for Active Remediation ex situ) is a thermal treatment strategy for contaminated soils and organic wastes. Key to this technology is that organics are embedded in porous matrix beds (e.g. sand). STARx induces a self-sustaining smouldering combustion front that traverses the bed, burning away the embedded contaminants/wastes. The time and cost effectiveness of this technology is largely dictated by the time required for cooling of the hot, clean, porous matrix bed that remains after treatment. This study is the first to explore the cooling of these beds. A suite of novel simulations investigated the influence of key parameters on bed-cooling time. The results reveal that cooling time decreased nearly linearly with decreases of volume-averaged bed temperature and bed bulk density. Increased injection air fluxes led to the non-linear decrease of cooling time. Also, cooling time was negatively impacted by bed temperature inhomogeneity, which influenced preferential air flow through cooler regions of the bed, bypassing hotter regions. From these results, using lower bulk density bed materials, increased air fluxes and enhancing wall insulation to improve bed temperature homogeneity were identified as system optimisations to reduce cooling times. While the aim of this research is to improve the STARx cooling process, the results are also highly applicable to many similar engineering systems that involve hot porous bed cooling.
STARx (Self-sustaining Treatment for Active Remediation ex situ) is a thermal treatment strategy for contaminated soils and organic wastes. Key to this technology is that organics are embedded in porous matrix beds (e.g. sand). STARx induces a self-sustaining smouldering combustion front that traverses the bed, burning away the embedded contaminants/wastes. The time and cost effectiveness of this technology is largely dictated by the time required for cooling of the hot, clean, porous matrix bed that remains after treatment. This study is the first to explore the cooling of these beds. A suite of novel simulations investigated the influence of key parameters on bed-cooling time. The results reveal that cooling time decreased nearly linearly with decreases of volume-averaged bed temperature and bed bulk density. Increased injection air fluxes led to the non-linear decrease of cooling time. Also, cooling time was negatively impacted by bed temperature inhomogeneity, which influenced preferential air flow through cooler regions of the bed, bypassing hotter regions. From these results, using lower bulk density bed materials, increased air fluxes and enhancing wall insulation to improve bed temperature homogeneity were identified as system optimisations to reduce cooling times. While the aim of this research is to improve the STARx cooling process, the results are also highly applicable to many similar engineering systems that involve hot porous bed cooling.
Entities:
Keywords:
Applied smouldering systems; STARx; cooling time reduction; forced convection; hot packed bed; process optimisation; thermally induced air channelling; waste thermal treatment
Smouldering combustion is an exothermic reaction in which heat and oxygen attack the
surface of a condensed phase fuel (Ohlemiller, 1985). A common example of
smouldering is the glowing red surface of charcoal briquettes in a barbeque.
Smouldering is ignited rapidly by a localised heat flux (e.g. a fire in a coal seam,
burning branch falling on peat forest floor). Through the convection and diffusion
of air, oxidiser (oxygen) is delivered to the reaction site, known as the
‘smouldering front’ (Rein,
2009; Torero et al.,
2020; Zanoni et al.,
2019a). Heat released from the oxidation reaction in the front is
transferred (via convection, conduction and radiation) to adjacent fuel (Ohlemiller, 1985). As a
result, the smouldering front propagates slowly through the fuel, consuming it in
the process. Smouldering fuels can be solid or liquid (Pironi et al., 2009, 2011; Switzer et al., 2009; Torero et al., 2020).
However, regardless of the fuel type, a key requirement for smouldering is the
presence of a porous matrix. This provides a network of paths for oxygen to reach
the fuel, a high surface area for mass and heat transfer and insulation of the
reaction (Rein, 2009;
Torero et al., 2020;
Yermán et al.,
2015). For instance, when smouldering a solid fuel such as charcoal, the
charcoal itself provides the porous matrix. Similarly, although liquid fuels (e.g.
coal tar) are non-porous, they can be made smoulderable by mixing with a porous
matrix such as quartz sand.A key feature of smouldering is that when conditions are appropriate (e.g. sufficient
fuel concentration, fuel type and air flux), the process is self-sustaining (Torero et al., 2020; Wyn et al., 2020; Zanoni et al., 2019a).
This means that more energy is generated (i.e. heat evolved from the oxidation
reactions) than is lost (e.g. to endothermic reactions like pyrolysis) and the front
progresses without any external energy input. As such, smouldering is a highly
energy-efficient process (Rashwan et al., 2021a, 2021b; Torero et al., 2020; Yermán et al., 2015). Smouldering is also
self-terminating as the reaction extinguishes upon fuel depletion (Crielaard et al., 2019;
Switzer et al.,
2014; Wang et al.,
2021).Smouldering combustion has been researched and/or applied in a variety of contexts
including fire safety (Bar-Ilan
et al., 2002; Leppänen and Malaska, 2019; Rein et al., 2008; Santoso et al., 2019; Steen-Hansen et al., 2018;
Torero and Fernandez-Pello,
1996; Yang and Chen,
2018), oil recovery/extraction (Akkutlu and Yortsos, 2003; Castanier and Brigham,
2003; Garon et al.,
1980; Martins et
al., 2010; Sennoune
et al., 2012; Xia et
al., 2003) and sanitation (Fabris et al., 2017; Saberi et al., 2020; Yermán et al., 2015). In addition, applied
smouldering systems have also emerged as a viable thermal strategy for in situ and
ex situ treatment of hydrocarbon-contaminated soils (Ding et al., 2019; Gerhard et al., 2020; Grant et al., 2016; Scholes et al., 2015;
Vidonish et al.,
2016) as well as for disposal of waste organic liquids and sludges (e.g.
waste oil sludges, petroleum hydrocarbon products; Feng et al., 2021; Rashwan et al., 2021a; Serrano et al., 2020;
Wyn et al., 2020;
Yermán, 2016; Zhao et al., 2021). The
ex situ variant of these systems is commercially referred to as STARx
(Self-sustaining Treatment for Active Remediation ex situ; Rashwan et al., 2016; Sabadell et al., 2019;
Solinger et al.,
2020; Switzer et
al., 2014). For treatment, liquid or sludge wastes are mixed into
contaminated soils or with a porous matrix (e.g. sand) to make them smoulderable.
When remediating contaminated soils, the soil provides the porous matrix.In the STARx process, stockpiles of contaminated soil or different porous
matrix–waste mixtures are loaded on top of HottpadTM modules to form a
treatment bed (Figure 1).
These modules house the heating and air injection equipment used to ignite the
smouldering front at the base of the bed and propagate it upwards (Solinger et al., 2020).
The arrival of the front at the top of the bed indicates the end of the smouldering
phase. At this point, the embedded contaminants/wastes have been burned away leaving
behind only clean (i.e. carbon-free), treated bed material. STARx bed temperatures
can range from 500°C to 1250°C depending on a variety of factors such as the energy
content of the contaminant being oxidised. Therefore, the newly treated material
must be cooled sufficiently before it can be off-loaded and replaced with more
contaminated material. This portion of the treatment cycle is referred to as the
‘cooling phase’. The end of the cooling phase is designated as when the porous
matrix cools to a ‘safe-to-manage’ temperature, at which point unloading commences.
Figure 1 illustrates
the STARx treatment system and the process progression.
Figure 1.
A conceptual diagram of each stage of the STARx process: (1) contaminated
soil/waste loading, (2) smouldering treatment and (3) clean treated material
unloading.
Adapted from Murray
(2019).
A conceptual diagram of each stage of the STARx process: (1) contaminated
soil/waste loading, (2) smouldering treatment and (3) clean treated material
unloading.Adapted from Murray
(2019).Through experimentation, pilot-scale STARx technology demonstrated that a 97%–99.95%
ex situ remediation efficiency was maintained for soil volumes up to 3 m3
(Switzer et al.,
2014). Murray
(2019) demonstrated the use of HottpadTM modules for ex situ
remediation at scales anticipated for commercial success (> 100 m3).
This provided the low-cost configuration of STARx (i.e. soil piles loaded on top of
HottpadTM modules), which is currently used in practice. STARx
Hottpads have since been commercially deployed in numerous locations worldwide
including Canada, Taiwan and the USA (https://www.savronsolutions.com/).As a thermal remediation strategy, STARx technology offers a multitude of benefits.
For example, due to the self-sustaining nature of smouldering, STARx does not
require consistent input of external fuel or energy (Duchesne et al., 2020; Murray, 2019). As a
result, STARx is a highly energy-efficient treatment process and ranks exceptionally
well on quantitative sustainability assessments (Gerhard et al., 2020). Other benefits are
that STARx can be deployed as an on-site treatment process, in liquid smouldering
applications the porous matrices can be reused between treatment cycles, it is
easily scalable and its high degree of waste/contaminant destruction reduces
environmental liabilities (Solinger et al., 2020).Even given these advantages, process optimisations are needed to further increase
effectiveness as well as reduce energy requirements, treatment times and costs. One
such area for optimisation is the cycle treatment time, which can depend largely on
the time required for hot post-treatment beds to cool sufficiently for unloading.
Currently, cooling is carried out by continuing the air injection used previously to
sustain the smouldering treatment. At present, the cooling phase duration can be
similar to that of the smouldering treatment phase; for example, 6 days for
treatment and a total treatment cycle time of nearly 12 days when accounting for
cooling (Savron Solutions, personal communication).Understanding and predicting how hot bed-cooling times can be reduced is needed, both
for STARx and other thermal treatment technologies such as pyrolysis, incineration
and gasification. However, air flow cooling of hot porous beds has not been strongly
investigated. STARx research has predominately focused on the smouldering phase with
no publications considering cooling phase processes or optimisations. Experiments
(Laguerre et al.,
2006; Pastore et
al., 2018), analytical solutions (Kuznetsov, 1994, 1995, 1997; Riaz, 1978) and numerical/computational
models (Kaviany, 1985;
Kuwahara et al.,
2000; Nijemeisland
and Dixon, 2004) have focused on bed heating to investigate forced
convection in porous media. Research on packed bed thermal energy storage (PBTES)
systems (Cascetta et al.,
2016; Sanderson and
Cunningham, 1995), specifically for solar thermal energy (Gautam and Saini, 2020;
Klein et al., 2014;
Kuravi et al.,
2013), has provided some insight into their thermal discharging. For these
systems, studies have estimated bed-cooling time based on the velocity of a
one-dimensional thermocline traversing the bed (McTigue et al., 2018; Torab and Beasley, 1987;
White, 2011).
However, this approach is not suitable for applications in which flow and heat
transfer characteristics are not simple, including STARx and other solid particle
processes such as coke dry quenching (CDQ) and iron ore sintering in the metallurgy
sector (Jiang et al.,
2019; Zhou et al.,
2015).In these cases, cooling can be subject to numerous sensitivities either unknown or
with limited investigation. In particular, the influence of bed temperature
inhomogeneities on cooling air flow distribution, of which there are only a few
studies. Through numerical modelling of heated gas flow into a bed, several older
studies identified the reduction of air flow through higher temperatures bed regions
(Stanek and Szekely,
1973; Stanek and
Vychodil, 1987; Vortmeyer et al., 1992; Wonchala and Wynnyckyj, 1987). More
recently, Davenne et al.
(2018) highlighted how the presence of a small, near-inlet, cool zone in
a heated bed can substantially impact thermocline uniformity during cooling. In
these few studies, the results were attributed to the temperature-dependent
properties of the injected gas, but the process fundamentals or impact on bed
cooling were not explored. This important system dynamic is investigated in
substantial detail in this study.Through novel simulations, this work studies the influence of key system parameters
on the cooling time of hot inert porous matrix beds. This research examines the
sensitivity of the cooling time to key operational variables – some within and some
outside operator control – including the initial volume-averaged temperature of the
bed, the temperature distribution within the bed at the start of cooling, the bulk
density of the bed material and the applied injection air flux. The poorly
understood thermal implications of hot porous matrix material on bed pneumatic
conductivity and resulting air flow patterns are explored and explained. The impact
of air flow divergence around hot zones on bed cooling is quantified. Furthermore,
novel optimisation methods are provided for reducing cooling times, thereby
increasing energy efficiency and reducing cost. Overall, this work provides new
scientific insights as well as practical measures for a wide range of scientists and
commercially active engineers.
Methods
In this work, ANSYS® Student Fluent 2020 R1/R2 was employed to simulate
the cooling of heated porous matrix beds via air flow. Smouldering was not
simulated, and contaminant treatment was assumed to have just completed at the start
of each simulation.
Model formulation
Governing equations
Air flow within the porous space was modelled as an incompressible fluid
(Rashwan et al.,
2021c) under fully developed, laminar conditions. The air density
was determined by local temperatures at each timestep by the ideal gas law
(Zanoni et al.,
2017). The packed bed was assumed to be physically homogeneous
and isotropic, and composed of spherical particles with an assigned
intrinsic permeability
and porosity
. The model solved the multi-dimensional mass and momentum
conservation equations in the porous bed:The momentum equation, for steady flow at low Reynolds number
(
) with negligible macroscopic viscous effects (i.e.
Brinkman term), reduces to Darcy’s law (equation (2)).Energy conservation was governed by Fluent’s Local Thermal Non-Equilibrium
Model (LTNE), which follows a dual cell approach in which spatially
coincident solid and porous gas zones are defined and heat transfer is the
only interaction between these zones (ANSYS Inc, 2020a). The effects of
viscous dissipation on the low
, single phase flow is assumed to be negligible. The energy
equations of the gas (air) and solid (sand) phases were:where the interfacial area density (i.e. specific surface area) of the grains
was calculated as
. Radiation heat transfer was accounted for through
implementation of a radiative conductivity, which followed the Rosseland
approximation
(Rashwan et al., 2021c; Zanoni et al., 2017). Heat
transfer between the solid and gas phase was regulated by the solid–gas heat
transfer coefficient,
, estimated by Zanoni et al. (2017):This equation is valid for
= 0.72, 0.125 mm ≤
≤ 2.000 mm, and 0 ≤
≤ 31, which is consistent with the cases to be presented.
Moreover, this
correlation is best suited for the low Reynolds number
flows applied during STARx operation (Rashwan et al., 2021c).
Computational domain and boundary conditions
For this study, two-dimensional (2D) grids were created to represent the
vertical cross-section of a STARx treatment bed (Figure 3). Based on a field-scale
system, the simulated system was 9.3 m wide and 2.5 m high. The width was
implemented by creating a 4.65 m wide domain with a centreline symmetry
boundary to reduce the computational cost of the simulations. The meshing
procedure provided a domain of 3393 equally sized quadrilateral elements,
chosen to balance accuracy with computational efficiency. Supplement A provides visualisation of the structured
mesh.
Figure 3.
Implemented initial temperature (left-side) and resulting pneumatic
conductivity (right-side) distributions: (a) and (b) Cool Edge (Base
Case)], (c) and (d) Homogeneous, (e) and (f) Vertical Gradient and (g)
and (h) Horizontal Gradient. The position of sampling locations A, B, C
and D are indicated (black lines, top of each domain) as well as the
inlet/ignition location (red line, bottom of each domain).
For the dual cell approach, boundary conditions specific to each phase were
required. For the porous gas phase, an inlet velocity boundary at the base
of the bed allowed for air injected at ambient temperature
. Air exited the bed through a ‘pressure outlet’ boundary
at the top of the domain, which imposes a constant static pressure and zero
velocity gradient. This boundary represented the gas flow entering a hood
space upon exiting the bed, reflecting commercial practice. From the hood
space, air is extracted and channelled to emissions treatment systems,
although this is not included in the computational domain. Although
enclosed, the hood space is not sealed off, so atmospheric pressure
was applied at the outlet. The right-side wall boundary
was set as zero shear due to low
flow (i.e. negligible velocity boundary layer effects),
and zero heat flux, assuming negligible conductive heat transfer from the
air to the wall. For the solid phase, the inlet and outlet were set as zero
heat flux boundaries as heat transfer at these boundaries is predominantly
through air convection. The right-side wall boundary was fixed at ambient
temperature representing external heat loss due to lack of insulation. The
left-side symmetry boundary was common to both phases. See Supplement A for a tabulated summary of all applied boundary
conditions.
Model validation and verification
The model was validated against laboratory reactor data (Zanoni et al., 2021) during the
experiment’s cooling phase (i.e. after smouldering was extinct). Temperature
readings were compared at centerline and near-wall positions (i.e. 2D
validation). An experiment description and the model parameters employed are
provided (Supplement B). Temperatures produced from the experiment and
model were compared at centerline (Figure 2(a)) and radial (i.e. near to
the column; Figure
2(b)) positions.
Figure 2.
Comparison of experimental and modelled temperatures during the cooling
phase. Temperatures are compared at different heights and at (a)
centerline and (b) near-wall positions.
Comparison of experimental and modelled temperatures during the cooling
phase. Temperatures are compared at different heights and at (a)
centerline and (b) near-wall positions.The Normalised Root-Mean-Square Deviation between the numerical and experimental
datasets was low (7%). This validation procedure provides confidence that the
model properly simulates 2D packed bed cooling. In addition, it was confirmed
that spatial and temporal discretisation were acceptable, and results were
grid-independent (Supplement C).
Overview of simulations
First, a Base Case simulation was created which employed a packed bed of
medium-grained sand (mean particle diameter,
, of 0.5125 mm) with its properties experimentally determined
(Zanoni et al.,
2017); this is hereafter referred to as ‘Base Case sand’. The Base
Case injection air flux was set at 1 cm s−1 as commonly used in STARx
systems. The bed was initialised with the ‘Cool Edge’ temperature distribution
(Figure 3(a)) in
which the domain was homogeneously initialised at 562°C except for 0.2 m wide
near-wall and near-inlet ‘strips’, which were initialised at 40°C. These lower
temperature strips reflect the influence of heat losses occurring during
treatment and temperatures are representative of those seen in practice at the
start of the cooling phase. Overall, the initial volume-averaged bed temperature
was 500°C. The Base Case parameter/material properties are summarised in Table 1, noting that
is the Base Case sand thermal conductivity,
is the molecular weight of air and
is the particle density of sand, which is converted to bed
bulk density by the relationship presented in equation (6) (Tiskatine et al.,
2017):
Table 1.
Base case simulation parameter set.
Parameters
Values
Units
Cpg
−3×10−5(Tg2)+0.2261Tg+940.35a
(J kg−1 K−1)
Cps
2.49Ts+39.06a
(J kg−1 K−1)
Kg
−1×10−8(Tg2)+8×10−5(Tg)+4.3×10−3a
(W m−1 K−1)
krad+ks
1.55×10−10(Ts3)+0.000541(Ts)+0.1044
(W m−1 K−1)
μg
−9×10−12(Tg2)+4×10−8(Tg)+6×10−6a
(Pa s)
ki
1.84×10−10a
(m2)
Po
101,325b
(Pa)
Mw
0.029b
(kg mol−1)
ρs
2635a
(kg m−3)
dp
5.125×10−4a
(m)
ϕ
0.37a
(–)
Asg
7376c
(m)
qg
0.01d
(m s−1)
To
298.15b
(K)
Values obtained from the study by Zanoni et al. (2017).
Values obtained from ANSYS® Student Fluent
reference/default values.
Values obtained from calculation.
Values obtained from the study by Murray (2019).
Base case simulation parameter set.Values obtained from the study by Zanoni et al. (2017).Values obtained from ANSYS® Student Fluent
reference/default values.Values obtained from calculation.Values obtained from the study by Murray (2019).Next, three simulations examined the influence of the initial volume-average
temperature of the bed. The simulations cover the range 500°C (Base Case) to
1250°C, which represents the smouldering of a wide range of fuels/contaminants
(Duchesne et al.,
2020; Gerhard et
al., 2020). Three simulations then analysed the influence of initial
bed temperature distribution. The temperature distributions applied were
Homogeneous (Figure
3(c)), Vertical Gradient (Figure 3(e)) and Horizontal Gradient
(Figure 3(g)). All
are approximations of observed temperature distributions in STARx beds depending
on heat losses, wall insulation, fuel smouldering temperatures and other
scenario-specific variables.Implemented initial temperature (left-side) and resulting pneumatic
conductivity (right-side) distributions: (a) and (b) Cool Edge (Base
Case)], (c) and (d) Homogeneous, (e) and (f) Vertical Gradient and (g)
and (h) Horizontal Gradient. The position of sampling locations A, B, C
and D are indicated (black lines, top of each domain) as well as the
inlet/ignition location (red line, bottom of each domain).Three simulations then investigated the influence of varying bed bulk density
from 415 to 2490 kg m−3; this presents a range from natural soils to
operator-controlled mixtures. In addition, the influence of injection air flux
was explored through three simulations in which it was incremented from 1.0
(Base Case) to 3 cm s−1; a range covering the equipment typically
available on a STARx site. Aside from the stated variable changes, each
simulation was created using the Base Case setup. This is with exception to the
Homogeneous case, in which wall heat losses were disabled to prevent horizontal
temperature gradients from forming during cooling.For a cooling metric, bed-cooling time (
) is defined as the time required for the mass-averaged
temperature of the air exiting the bed (
) to decrease to ambient temperature. This indicates that the
total heat load (i.e. the initial sensible heat storage,
) has been transferred out of the bed. Mass-averaging of the
outlet air temperature was calculated at each time step by:where
is the dot product of the cell air flow velocity and area
vectors,
is the total number of outlet cells and
is the instantaneous cooling time.
and
are the air temperature and density of cell
, respectively (ANSYS Inc, 2020b).only considers sensible heat storage in the bed material as
gas phase contribution is typically minimal (Alva et al., 2018; White, 2011) and
assumed negligible.
is calculated in the Fluent model following:where
is the total number of cells in the domain,
is the volume of cell
and
and
are the Base Case sand mass and specific heat capacity,
respectively.
is sensible enthalpy and is calculated for either the sand or
air phase as
.The rate at which the injected air flow removes heat from the bed
is calculated throughout each simulation as:where
and
are the outlet mass flow rate and specific heat capacity of
air, respectively. Important to note is that
is directly influenced by the applied injection air flux. Heat
is also removed from the bed through the wall boundary by lateral heat transfer
(i.e. conduction). The wall heat loss rate from the sand phase is calculated
as:where ∆
is the solid cell to wall surface distance,
is the total number of near-wall solid cells and
is the wall surface temperature (ANSYS Inc, 2020a).Total outlet and wall heat losses are calculated by integrating equations
(9) and (10) over the cooling
durations. The average heat loss rate through either boundary was determined by
dividing total heat loss through that boundary by the bed-cooling time.In addition, for each simulation, the distribution of air flow leaving the top of
the bed was assessed. Figure
3 displays that four ‘sampling locations’ were arranged along the
outlet boundary of the domain. Each sampling location was created as a line
surface, 1 m in length, and equally spaced across the outlet. Mass flow data
were integrated over the cooling duration to determine the total percent of air
flow (by mass) through each location.
Results and discussion
Base Case
The Base Case simulation resulted in a cooling time of 7.7 days. The majority of
heat loss was through the bed outlet via the exiting hot air flow (~ 99%), while
wall heat losses were negligible (~ 1%). This corresponded to average heat loss
rates of approximately 40 kW and 0.3 kW, respectively. Initial sensible heat
storage in the bed (i.e. the total heat load) was 7364 kWhth.Figure 4 displays the
evolution of bed temperature distribution with time. In particular, a ‘heat
bulb’ was observed to deflect air flow towards the near-wall region, where flow
velocities were greatest (~ 11 cm s−1 maximum velocity, compared to ~
8 cm s−1 closer to the bed centre). This thermally induced air
channelling occurred due to spatial and temporal variations in pneumatic
conductivity (
).
refers to the ease at which air can flow through a porous bed
(Zanoni et al.,
2021):
Figure 4.
Bed temperature distributions observed throughout the Base Case
simulation: (a) at the start of cooling, (b) after 25% of total cooling
time was completed (1.9 days), (c) 50% (3.9 days), (d) 75% (5.8 days)
and (e) at the end of cooling (7.7 days).
where
is the air density and
is the air viscosity,
is the intrinsic permeability of the bed and
is gravitational acceleration. As
decreases and m
increases with increasing temperature,
decreases. Therefore, higher temperature regions of the bed
are less conductive to air flow. This effect is similar to how physically
induced air channelling can occur due to permeability heterogeneity (Rashwan et al., 2021c;
Wang et al.,
2021) and porosity variations (Dalman et al., 1986; Laguerre et al., 2006;
Meier et al.,
1991).Bed temperature distributions observed throughout the Base Case
simulation: (a) at the start of cooling, (b) after 25% of total cooling
time was completed (1.9 days), (c) 50% (3.9 days), (d) 75% (5.8 days)
and (e) at the end of cooling (7.7 days).Recall that exit airflow sampling locations (A through D) were included (Figure 3(a)). For the
Base Case, this revealed that near-wall air flow (through sampling location D)
accounted for the greatest portion (~ 29%) of the total air flow (Figure 6). Preferential
air flow in this region led to the adjacent region (sampling location C)
experiencing the least proportion of air flow (~ 23%). This is because the C
sampling location was positioned overtop of the ‘low
heat bulb’ (Figure 4(d)). Following the sharp flow reduction at location C, air
flow uniformity increased with greater distance from the wall, towards the bed
centre (sampling locations A and B).
Figure 5.
(a) Total cooling times and the percentage change (relative to the Base
Case simulation) of initial heat storage in the bed (i.e. the heat load)
and the average outlet heat loss rate with variation of initial
volume-averaged bed temperature. (b) Comparison of Base Case sand and
air specific heat capacities over the range of bed temperatures
implemented.
Comparison of Figure
4(d) and (e)
reveals that ~ 2 days was required for complete cooling of the ‘heat bulb’.
Overall, this highlighted how air divergence can be problematic for bed cooling.
Air flow will tend to bypass higher temperature regions in favour of cooler
ones, prolonging the cooling process. Of particular concern is bypassing through
regions near containment walls, where heat losses lead to lower temperatures and
higher
. This phenomenon is known but has not been studied and is much
further examined – particularly with respect to impact on cooling times – in the
upcoming sections. Note that for all simulations, video files detailing the
evolution of bed temperature distribution are provided in the Supplemental Material.
Initial volume-averaged temperature
Increased initial volume-averaged bed temperature led to a nearly linear increase
in cooling time (Figure
5(a)) from 7.7 days in the Base Case (500°C) to 15.4 days in the
1250°C case. This was primarily due to the greater increase of the bed total
heat load with temperature in comparison to the average outlet heat loss rate
(Figure 5(a)).
Acknowledging that the mass of the bed and the mass flow rate of air were held
constant between these simulations, heat load and outlet heat loss changes were
solely dependent on the specific heat capacities of the Base Case sand and air,
respectively.(a) Total cooling times and the percentage change (relative to the Base
Case simulation) of initial heat storage in the bed (i.e. the heat load)
and the average outlet heat loss rate with variation of initial
volume-averaged bed temperature. (b) Comparison of Base Case sand and
air specific heat capacities over the range of bed temperatures
implemented.The increase of heat storage in packed beds due to the increase of bed material
specific heat capacity with temperature is well known (Aly and El-Sharkawy, 1990; Ammar and Ghoneim,
1991; Elouali et
al., 2019; Hrifech et al., 2020; Kumar and Shukla, 2015; Tiskatine et al.,
2017). In agreement, Figure 5(b) confirms increase of the Base Case sand specific heat
capacity with temperature. Notice that this increase is more rapid than that of
the specific heat capacity of air. This reflects the previous comparison made
between the increases of heat load and the average outlet heat loss rate as bed
temperature was increased. Therefore, in addition to greater total heat loads at
higher temperatures, the cooling process was also inhibited by the air’s
specific heat capacity. This effectively limited the rate at which heat could be
transferred to the air and removed from the bed. These results call attention to
higher temperature STARx applications (e.g. > 900°C for PFAS treatment),
which are intrinsically susceptible to longer cooling times.
Initial temperature distribution
Varying the initial temperature distribution investigated how spatial temperature
inhomogeneities altered air flow distribution in the bed and impacted cooling
time. For the Homogeneous distribution, bed
homogeneity was featured at cooling start (Figure 3(d)). The even
distribution of total air flow (Figure 6) indicates that this
temperature distribution prevented any air divergence from occurring. As a
result, the Homogeneous distribution led to the fastest cooling time, 7.2 days,
a 0.5 day (or 6%) reduction from the Base Case.
Figure 6.
Total air flow distribution among the outlet sampling locations for each
initial temperature distribution. Corresponding cooling times are
labelled.
Total air flow distribution among the outlet sampling locations for each
initial temperature distribution. Corresponding cooling times are
labelled.In contrast, the Vertical and Horizontal Gradient cases featured temperature
variation in the axial and lateral directions, respectively (Figure 3). Note that the
Horizontal Gradient featured high
‘layers’ aligned parallel to the primary flow direction (inlet
to outlet). Conversely, the majority of temperature layers in the Vertical
Gradient were normal to the primary flow direction, with only the cool near-wall
region extending parallel to it. As such, Figure 6 shows that total air flow
distribution varied drastically across the bed for the Horizontal Gradient and
led to the longest cooling duration (13.9 days, Figure 6). By measure, the total air
flow distribution of the Vertical Gradient resembled that of the Base Case, with
air divergence only near to the wall. Accordingly, the Vertical Gradient cooling
time (8.3 days, Figure
6) was an increase of only 0.6 days (or 8%) from the Base Case.
Importantly, these observations make evident that the degree of air divergence
and resulting cooling time increases are driven by the extent of temperature
variation perpendicular to the dominant air flow directions in the bed.Bed temperature inhomogeneity has been investigated relative to its role in
smouldering reaction dynamics. Namely, its influence on injected air flow rates
(Levin and Lutsenko,
2006, 2008), non-uniform air flux (Rashwan et al., 2021c), pressure
changes within smouldering reactors (Zanoni et al., 2021) and reaction
front instability (Chen et
al., 2018; Rabinovich et al., 2016). Relatedly, the results of this work
provide the first investigation into how bed temperature inhomogeneities derived
during the smouldering phase can have ramifications for the cooling phase.
Specifically, by resolving the flow field within the bed (Supplement D) and highlighting that the occurrence of thermally
induced air flow redistribution leads to longer cooling times.
Porous bed bulk density
For liquid waste smouldering, the bed bulk density can be controlled by changing
the type of porous matrix material chosen during system set-up. Recalling equation
(6), it is seen that the bulk density of a material is a function of
its particle density
as well as its porosity
. Relatedly, it has been reported that the heat load in a
packed bed (relative to a set temperature) is increased through use of materials
with greater particle density (Aly and El-Sharkawy, 1990; Elouali et al., 2019;
Hrifech et al.,
2020; Romaní et
al., 2019) and/or reduced porosity (Abdel-Salam et al., 1991; Ismail and Stuginsky,
1999). Altering either of these parameters in this manner would also
lead to an increase in the bed bulk density (equation (6)). In agreement,
Figure 7(a)
displays that direct increases of the bed bulk density caused a linear increase
of total heat load.
Figure 7.
Total cooling times and the percentage change (relative to the Base Case
simulation) of initial heat storage in the bed and the average outlet
heat loss rate due to variation of (a) bed bulk density and (b) applied
injection air flux.
Total cooling times and the percentage change (relative to the Base Case
simulation) of initial heat storage in the bed and the average outlet
heat loss rate due to variation of (a) bed bulk density and (b) applied
injection air flux.It was also seen that the average outlet heat loss rate was unaffected by bulk
density variations (Figure
7(a)). Rather, it remained unchanged as all beds were initialised at
Base Case temperature and distribution (500°C, Cool Edge). This meant that
sand–air heat transfer was driven by the same temperature differentials
regardless of changes to bed bulk density. Therefore, with average heat removal
rate constant and only the heat load varied between each simulation, cooling
time was observed to be linearly proportional to the bed bulk density (Figure 7(a)). Altogether,
this indicated that porous matrix material selection (a key step of system
design) offers STARx operators substantial cooling time control.
Injection air flux
Air flux increases were found to reduce cooling time significantly (Figure 7(b)), as greater
injection air fluxes enhanced the sand-to-air heat transfer process. This is
inferable as the sand–air heat transfer coefficient
is a function of Reynolds number (equation
(5)), which increases at higher flow velocities. Significant increase
of outlet heat loss rates were indicative of heat transfer enhancement and
faster heat load removal. For instance, the 3 cm s−1 air flux
increased the average outlet heat loss rate by 231% from the Base Case (Figure 7(b)) and reduced
cooling times to 2.3 days. This was a 70% decrease from the 7.7 day Base Case
cooling time. Increasing instead to only 2 cm s−1 reduced cooling
time by 53% relative to the Base Case (from 7.7 days to 3.6 days) and increasing
only to 1.5 cm s−1 resulted in a 36% reduction (from 7.7 days to
4.9 days). These results agree qualitatively to research on thermal energy
systems, which indicated that increased heat transfer fluid injection rates
reduced thermal discharging times (Gautam and Saini, 2020; Kim et al., 2017;
Lugolole et al.,
2019; Niyas et
al., 2015; Suresh and Saini, 2020; Xu et al., 2012). The cooling time
reduction here was revealed to be non-linear with air flux (Figure 7(b)).
Optimisations for cooling time reduction
This work reveals new optimisation opportunities for STARx systems with respect
to cooling time reduction:Increased injection air flux during the cooling phase. Greater injection
air fluxes enhanced sand–air heat transfer and led to significant
increases of outlet heat loss rate. All air flux increases beyond the
Base Case (1 cm s−1) led to reduced cooling times. This
highlighted a strong, system-embedded approach to cooling duration
control for site engineers as air injection equipment is an essential
operational component of STARx and other thermal waste treatment
systems.The use of packed bed materials with lower bulk densities. This is
supported by the linear proportionality observed between cooling time
and bulk density. Importantly, bulk density can be controlled by the
operator during system set-up. Examples of potential alternative inert
porous matrix materials to quartz sand include alumina spheres and
pumice, among many others. However, aside from cooling time reductions,
alternative bed materials should also be cost effective and commonly
available (Savron Solutions, personal communication). Both of which are
advantages that sand offers when used in packed bed smouldering (Yermán et al.,
2015) and thermal energy storage (Alva et al., 2018) systems
alike.Enhancement of containment wall insulation. Horizontal temperature
gradients were found to influence substantial air divergence and
increase cooling time. In agreement, temperature homogeneity led to
reduced cooling times. Greater homogeneity can be influenced by
minimising lateral heat losses via improved wall insulation, combating
the negative influence of thermally induced air channelling on cooling
times, particularly, at increased bed temperatures and in the near-wall
region where air divergences effects are more pronounced.Although not studied here, this work suggests that an additional option
for cooling time reductions would be the use of alternative heat
transfer fluids – with specific heat capacities greater than that of air
– during the cooling phase. Higher specific heat capacities would
facilitate increased sand–air heat transfer and outlet heat loss rates,
for faster heat load removal. Examples include thermal oils, as used in
some PBTES systems (Alva et al., 2018; Gautam and Saini, 2020). With
that said, air is generally favourable for porous bed cooling due to its
chemical stability, non-toxicity, non-flammability as well as unlimited
and effectively cost-free availability (Gautam and Saini, 2020; Park et al.,
2014).It is noted that air flux (Pironi et al., 2009, 2011; Rashwan et al., 2016; Zanoni et al., 2019a,
2019b), bed bulk
density (Hu et al.,
2020; Huang and
Rein, 2017; Krause et al., 2006; Prat-Guitart et al., 2016) and wall
heat loss/insulation (Lin
and Huang, 2021; Rashwan et al., 2021c, 2021d; Yermán, 2016) have all been considered
with respect to their influence on the smouldering reaction. However, the new
cooling optimisations reveal how key parameters quantitatively influence the
overall efficiency and effectiveness of commercial smouldering systems beyond
the smouldering phase. Therefore, total system assessment is imperative ahead of
real-world implementation of these optimisations. This includes properly
accounting for the foreseeable economic and implementation complexities (e.g.
equipment, material adjustments) of these optimisations.
Conclusion
This research explored the influence of key system parameters on the cooling time of
a waste thermal treatment bed. This investigation led to improved understanding of
bed-cooling dynamics and the identification of optimisations for cooling time
reduction. In addition to applied smouldering systems, the processes and
optimisations detailed in this research are highly applicable to a wide range of
engineering applications which involve air flow through hot beds and solid particle
cooling. The main findings of this research are summarised as follows:A near linear relationship was found between decreased cooling time and the
decrease of both the volume-averaged bed temperature and bed bulk
density;Bed temperature variation perpendicular to the dominant air flow direction
caused undesirable air divergence effects, particularly in the near-wall
region, and elongated cooling times;A non-linear relationship between increased injection air flux and reduced
cooling times was revealed. Modest increases in air flux led to significant
cooling time reductions;Based on these results, increasing injection air fluxes, use of lower bulk
density bed materials and improving containment wall insulation were
identified as practical system optimisations to reduce bed-cooling
times.Click here for additional data file.Supplemental material, sj-docx-1-wmr-10.1177_0734242X221076308 for Understanding,
controlling and optimising the cooling of waste thermal treatment beds including
STARx Hottpads by Ryan B Morales, Christopher T DeGroot, Grant C Scholes and
Jason I Gerhard in Waste Management & ResearchClick here for additional data file.Supplemental material, sj-docx-2-wmr-10.1177_0734242X221076308 for Understanding,
controlling and optimising the cooling of waste thermal treatment beds including
STARx Hottpads by Ryan B Morales, Christopher T DeGroot, Grant C Scholes and
Jason I Gerhard in Waste Management & Research
Authors: Grant C Scholes; Jason I Gerhard; Gavin P Grant; David W Major; John E Vidumsky; Christine Switzer; Jose L Torero Journal: Environ Sci Technol Date: 2015-11-16 Impact factor: 9.028
Authors: Paolo Pironi; Christine Switzer; Jason I Gerhard; Guillermo Rein; Jose L Torero Journal: Environ Sci Technol Date: 2011-02-25 Impact factor: 9.028
Authors: Christine Switzer; Paolo Pironi; Jason I Gerhard; Guillermo Rein; Jose L Torero Journal: J Hazard Mater Date: 2013-12-01 Impact factor: 10.588
Authors: Alexandra L Duchesne; Joshua K Brown; David J Patch; David Major; Kela P Weber; Jason I Gerhard Journal: Environ Sci Technol Date: 2020-09-04 Impact factor: 9.028
Authors: Ivo Fabris; Daniel Cormier; Jason I Gerhard; Tomek Bartczak; Mark Kortschot; Jose L Torero; Yu-Ling Cheng Journal: Fuel (Lond) Date: 2017-02-15 Impact factor: 6.609