L Ferrario1, E Garagiola2, C Gerardi3, G Bellavia4, S Colombo4, C Ticca4, C Rossetti4, M Ciboldi4, M Meroni4, A Vanzulli4, A Rampoldi4, T Bignardi4, F Arrigoni5, E Porazzi2, E Foglia2.
Abstract
BACKGROUND: To evaluate the potential benefits of the Magnetic Resonance-guided high intensity Focused Ultrasound (MRgFUS) introduction in the clinical practice, for the treatment of uterine fibroids, in comparison with the standard "conservative" procedures, devoted to women who wish to preserve their uterus or enhance fertility: myomectomy and uterine artery embolization (UAE).Entities:
Keywords: Decision support techniques; Economic evaluation; Magnetic resonance imaging/methods; Technology assessment; Ultrasound therapy/methods
Year: 2022 PMID: 35303183 PMCID: PMC8932203 DOI: 10.1186/s13561-022-00367-x
Source DB: PubMed Journal: Health Econ Rev ISSN: 2191-1991
Fig. 1Prisma Flow Chart
Results from the budget impact analysis assuming the NHS point of view
| 12-month clinical pathway, considering surgical procedure and follow-up | € 5,981,802,665.58 | € 5,601,246,799.34 | -€ 380,555,866.23 | −6.36% |
| Re-intervention rate | € 585,020,300.69 | € 544,232,524.43 | -€ 40,787,776.27 | −6.97% |
| 12-month clinical pathway, considering surgical procedure and follow-up | € 5,981,802,665.58 | € 5,563,238,083.08 | -€ 418,564,582.50 | −7.00% |
| Re-intervention rate | € 585,020,300.69 | € 541,165,322.12 | -€ 43,854,978.58 | −7.50% |
1 The baseline scenario assumed that all the patients were treated with the surgical approach
2 The real-life scenario assumed the implementation of all the technologies under assessment according to real-life practice case-mix (MRgFUS: 15.12%; UAE: 9.88%; Surgical setting: 75.00%)
3 The real-life scenario assumed the implementation of all the technologies under assessment according to real-life practice case-mix (MRgFUS: 15.12%; UAE: 9.88%; Surgical setting: 75.00%), considering all the MRgFUS to be conducted using a day-hospital approach
The quantitative assessment of the Organizational dimension
| Baseline scenario [minutes] | Real-life scenario [minutes] | Difference [minutes] | Difference % | |
|---|---|---|---|---|
| 219,614,418.54 | 184,048,954.57 | −35,565,463.97 | −16.19% | |
| 21,478,290.13 | 18,465,951.91 | −3,012,338.23 | −14.03% | |
Perceptions on equity, social, and legal dimensions
| Access to care on local level | −2.00 | 0.83 | −0.83 | 0.022 |
| Access to care for person of a legally protected status | −0.67 | 1.00 | 0.00 | 0.034 |
| Impact on the hospital waiting list | 0.17 | −1.83 | 0.17 | 0.048 |
| Generation of health migrations | 2.83 | 0.17 | 1.83 | 0.031 |
| Existence of factors influencing the patient’s ability and autonomy | 0.83 | 0.00 | 0.67 | 0.286 |
| Existence of factors limiting the use of the technology for a group of patients | 0.00 | 0.17 | 0.00 | 0.564 |
| Protection of persons of a legally protected status | 0.17 | 0.00 | 0.00 | 0.331 |
| Iniquity | 0.17 | 0.17 | 0.33 | 0.445 |
| Influence on the patient’s dignity | 0.17 | 0.17 | −0.17 | 0.321 |
| Influence on the patient’s religion | 0.00 | 0.00 | 0.00 | 0.786 |
| Ability of the technology to protect the patients’ autonomy | 2.50 | 0.33 | 1.50 | |
| Protection of human rights | 0.17 | 0.17 | 0.17 | |
| The use of technology guarantees the social values and the willingness to pay of the patient | 0.17 | 0.17 | 0.17 | |
| Protection of persons of a legally protected status | 0.17 | 0.17 | 0.17 | |
| Ability of the technology to protect the patients’ religion | 0.17 | 0.00 | 0.00 | |
| Impact of the procedure on the social costs | 2.17 | −0.17 | 1.50 | |
| Patients and citizens can have a good level of understanding of technology | 1.17 | 1.33 | 1.17 | |
| Impact of the procedure on the patient’s perceived quality of life | 2.67 | 1.00 | 1.67 | |
| Impact of the procedure on the care giver’s life and perception. | 2.33 | 1.17 | 1.50 | |
| Recovery rate | 3.00 | 0.33 | 1.83 | |
| Permission level of technology | 0.00 | 0.00 | 0.00 | 0,887 |
| Need for inclusion of the technology in registry | 0.00 | 0.00 | 0.00 | 0.864 |
| Fulfillment of the safety requirements | 0.67 | 0.67 | 0.67 | 0.941 |
| Infringement of intellectual property rights | 0.00 | 0.00 | 0.00 | 0.898 |
| The need to regulate the acquisition of technology | −0.17 | −0.17 | −0.17 | 0.886 |
| The legislation covers the regulation of technology for all categories of patients | 0.00 | 0.00 | 0.00 | 0.911 |
| The user manual of the technology is complete | 0.83 | 0.17 | 0.83 | 0.314 |