| Literature DB >> 35300793 |
Xinran Xiang1, Yuting Shang2, Fan Li1, Moutong Chen2, Jumei Zhang2, Qiang Wan3, Qinghua Ye2, Yu Ding4, Qingping Wu5.
Abstract
Strict monitoring of Salmonella serotypes is the most effective way to limit the risk of its transmission to humans. In this study, a microfluidic genoserotyping strategy was developed for the rapid and cost-effective detection of 11 common Salmonella serotypes from retail food samples, i.e. Typhimurium, Derby, Indiana, Agona, Rissen, Braenderup, Hadar, Enteritidis, Weltevreden, Meleagridis, and Pomona. The programmable LAMP in the strategy can complete the whole detection process within 40 min and avoid false positive results. The limit of detection was 102 or 103 CFU/mL. Referring to the results of standard culture method, the LAMP-chip was verified with 100% accuracy on testing 688 Salmonella and 22 non-Salmonella strains. This simple, portable and accurate microfluidic genoserotyping strategy is fully adapted to the needs of food regulatory authorities and has wide application prospect in food safety field.Entities:
Keywords: Food safety; Genoserotyping; Loop-mediated isothermal amplification; Salmonella
Mesh:
Year: 2022 PMID: 35300793 DOI: 10.1016/j.aca.2022.339657