Literature DB >> 35299722

Response to the Letter: "A Response to: Human Fall Detection Using Passive Infrared Sensors with Low Resolution: A Systematic Review" [Response To Letter].

Grégory Ben-Sadoun1,2, Emeline Michel3,4, Cédric Annweiler1,5,6,7, Guillaume Sacco3,5,8.   

Abstract

Entities:  

Mesh:

Year:  2022        PMID: 35299722      PMCID: PMC8922232          DOI: 10.2147/CIA.S362886

Source DB:  PubMed          Journal:  Clin Interv Aging        ISSN: 1176-9092            Impact factor:   4.458


× No keyword cloud information.

Dear editor

We read with interest the commentary proposed by Priastana & Simbolon: “A response to: Human Fall Detection Using Passive Infrared Sensors with Low Resolution: A Systematic Review”.1 We hope our present answers will help readers to fully appreciate the article. Regarding the non-registration of our study in any international database of prospectively registered systematic reviews, we specified this information at the beginning of the section Materials and Methods, sub-section Protocol and Registration.2 This study was therefore not registered, for example, in the PROSPERO database. We agree with Priastana & Simbolon on the additional precautions brought by registration in this type of database particularly to avoid duplication of scientific effort. However, the affirmation “to be reviewed by peers” is not correct. Indeed, PROSPERO is a registration system (accessible on the website ), which help researchers to comply with PRISMA recommendations and improves transparency of the review process. No peer review is carried out by the PROSPERO team. The latest PRISMA guidelines3 recommend to specify the registration information if the study was submitted, or, if it is not the case, to state that the review has not been registered, which we did (see also the PRISMA 2020 Checklist on the website ). Regarding the understanding of our flow chart, it is noticeable that the four studies were not “excluded” from the analysis as mentioned in the letter.1 All the precise details of the inclusions of the articles are given at the beginning of the section Result, sub-section The Steps of Articles Selection Process.2 We can summarize differently in this response why we mentioned 15 “real” reports of included studies out of 19 included articles. The article selection procedure led us to identify 19 articles after the successive exclusions which did not correspond to the topic of our systematic review (see our flowchart in2). Out of these 19 articles, we have four teams of researchers who have published their own work twice in two different journals or databases (ie, two articles with Fan as first author,4,5 two articles with Hayashida as first author,6,7 two articles with Tao as first author,8,9 and two articles with Taramasco as first author10,11). For each of these four teams, we therefore grouped their two articles (and not excluded) in the same analysis, ie in the same report. In the end, we have 15 reports. To help readers understand our flowchart, we recommend to read through our Table 1, which is divided in 15 lines (without counting the line of titles), each presenting a report. Eleven of them refer to a single study. Four of them refer to two studies. The latest recommendations from the PRISMA call for being more comprehensive regarding the description of selection article process and more specific regarding the vocabulary used (see the glossary in Box 1 of3), as we did. We studied the latter guide3 with great attention to carry out a methodologically rigorous systematic review. Note that our systematic review was submitted to the journal Clinical Intervention In Aging, which carried out the standard procedures for examining systematic review. Our systematic review and the PRISMA 2020 checklist were submitted for examination by several reviewers. We plan to publish soon a different approach to detect falls in older adults (with this type of sensor and others). Such different approach could help design fall detection systems, which would be more accurate and better adapted to houses and medical units.
  4 in total

1.  System Design for Emergency Alert Triggered by Falls Using Convolutional Neural Networks.

Authors:  Carla Taramasco; Yoslandy Lazo; Tomás Rodenas; Paola Fuentes; Felipe Martínez; Jacques Demongeot
Journal:  J Med Syst       Date:  2020-01-06       Impact factor: 4.460

2.  The PRISMA 2020 statement: an updated guideline for reporting systematic reviews.

Authors:  Matthew J Page; Joanne E McKenzie; Patrick M Bossuyt; Isabelle Boutron; Tammy C Hoffmann; Cynthia D Mulrow; Larissa Shamseer; Jennifer M Tetzlaff; Elie A Akl; Sue E Brennan; Roger Chou; Julie Glanville; Jeremy M Grimshaw; Asbjørn Hróbjartsson; Manoj M Lalu; Tianjing Li; Elizabeth W Loder; Evan Mayo-Wilson; Steve McDonald; Luke A McGuinness; Lesley A Stewart; James Thomas; Andrea C Tricco; Vivian A Welch; Penny Whiting; David Moher
Journal:  BMJ       Date:  2021-03-29

3.  A Response to: Human Fall Detection Using Passive Infrared Sensors with Low Resolution: A Systematic Review [Letter].

Authors:  I Ketut Andika Priastana; Juana Linda Simbolon
Journal:  Clin Interv Aging       Date:  2022-02-17       Impact factor: 4.458

Review 4.  Human Fall Detection Using Passive Infrared Sensors with Low Resolution: A Systematic Review.

Authors:  Grégory Ben-Sadoun; Emeline Michel; Cédric Annweiler; Guillaume Sacco
Journal:  Clin Interv Aging       Date:  2022-01-13       Impact factor: 4.458

  4 in total