| Literature DB >> 35295698 |
Asma Deeb1, Saif Al Yaarubi2, Bassam Bin Abbas3, Jamal Al Jubeh4, Deepti Chaturvedi5, Noura Al Hassani6, Angham Mutair7, Neamat Al Masri1, Yazan Al Sanad1, Azza Al Shidhani2, Noha Samir Mahmoud8, Abdullah Alherbish8, Martin O Savage9.
Abstract
Objective: This study aimed to assess patient perceptions of the use of the EasyPod™ growth hormone delivery device and its association with compliance.Entities:
Keywords: EasyPod™; compliance; growth hormone deficiency; injector device features; recombinant human growth hormone
Year: 2022 PMID: 35295698 PMCID: PMC8918687 DOI: 10.3389/fped.2022.839278
Source DB: PubMed Journal: Front Pediatr ISSN: 2296-2360 Impact factor: 3.418
Baseline demographic profile (N = 186).
| Mean (±SD) age | 11.8 (±2.76) |
| Sex ratio (M:F) | 117:65 |
| GH indication | |
| GH deficiency | 91 (48.9) |
| Panhypopituitarism | 6 (6.6%) |
| Idiopathic short stature | 40 (21.5) |
| Small for gestational age | 29 (15.6) |
| Chronic renal failure | 6 (3.2) |
| Turners syndrome | 6 (3.2) |
| Noonan syndrome | 5 (2.7) |
| Skeletal dysplasia | 4 (2.2) |
| Fanconi Bickel syndrome | 2 (1.1) |
| Rheumatoid disease | 1 (0.5) |
| Osteogenesis imperfect | 1 (0.5) |
| Total | 185 |
| Duration of GH indication in years [Mean (±SD)] | 3.74 (±2.9) |
| Average compliance (%) | 87% |
| Mean compliance (<90%) (Range) | 79% (50–89%) |
| Mean compliance (≥90%) (Range) | 95% (90–100%) |
Gender information is missing for four patients.
Indication data is missing for one patient.
Proportion of patients with GH deficiency.
Comparison between compliance groups for the usefulness of automated dose delivery and tracking features (N = 186).
|
|
|
|
|
| ||
|---|---|---|---|---|---|---|
|
| ||||||
| Hidden needle that auto-injects the medicine | Un-useful | 0 (0.0) | 0 (0.0) | 0 (0.0) | 18.943 | <0.001 |
| Less useful | 9 (10.5) | 1 (1.0) | 10 (5.4) | |||
| Neutral | 16 (18.6) | 7 (7.0) | 23 (12.4) | |||
| Useful | 22 (25.6) | 18 (18.0) | 40 (21.5) | |||
| Very Useful | 39 (45.3) | 74 (74.0) | 113 (60.8) | |||
| Skin sensor that helps with injection technique | Un-useful | 0 (0.0) | 0 (0.0) | 0 (0.0) | 14.756 | <0.001 |
| Less useful | 4 (4.7) | 0(0.0) | 4 (2.2) | |||
| Neutral | 15 (17.4) | 11 (11.0) | 26 (14.0) | |||
| Useful | 33 (38.4) | 21 (21.0) | 54 (29.0) | |||
| Very Useful | 34 (39.5) | 68 (68.0) | 102 (54.8) | |||
| Preset dosing so no daily dialing is required | Un-useful | 0 (0.0) | 1 (1.0) | 1 (0.50) | 6.616 | 0.010 |
| Less useful | 0 (0.0) | 0 (0.0) | 0 (0.0) | |||
| Neutral | 15 (17.4) | 8 (8.0) | 23 (12.4) | |||
| Useful | 20 (23.3) | 14 (14.0) | 34 (18.3) | |||
| Very Useful | 51 (59.3) | 77 (77.0) | 128 (68.8) | |||
|
| ||||||
| History of injected and missed doses | Un-useful | 14 (16.3) | 2 (2.0) | 16 (8.6) | 23.266 | <0.001 |
| Less useful | 4 (4.7) | 0 (0) | 4 (2.2) | |||
| Neutral | 14 (16.3) | 6 (6.0) | 20 (10.8) | |||
| Useful | 13 (15.1) | 14 (14.0) | 27 (14.5) | |||
| Very Useful | 41 (47.7) | 78 (78.0) | 119 (64.0) | |||
| Amount of medicine left in cartridge reminding patients of time to change cartridge | Un-useful | 7 (8.1) | 2 (2.0) | 9 (4.8) | 17.908 | <0.001 |
| Less useful | 15 (17.4) | 5 (5.0) | 20 (10.8) | |||
| Neutral | 24 (27.9) | 19 (19.0) | 43 (23.1) | |||
| Useful | 20 (23.3) | 28 (28.0) | 48 (25.8) | |||
| Very Useful | 20 (23.3) | 46 (46.0) | 66 (35.5) | |||
| Battery power left | Un-useful | 15 (17.4) | 4 (4.0) | 19 (10.2) | 20.375 | <0.001 |
| Less useful | 9 (10.5) | 9 (9.0) | 18 (9.7) | |||
| Neutral | 26 (30.2) | 14 (14.0) | 40 (21.5) | |||
| Useful | 18 (20.9) | 25 (25.0) | 43 (23.1) | |||
| Very Useful | 18 (20.9) | 48 (48.0) | 66 (35.5) | |||
n (%).
Comparison between compliance groups for the preferred personalized device features (N = 186).
|
|
|
|
|
| |
|---|---|---|---|---|---|
| Colorful covers | 22 (25.6) | 22 (22.0) | 44 (23.7) | 1.151 | 0.562 |
| Device skins | 16 (18.6) | 20 (20.0) | 36 (19.4) | 0.058 | 0.810 |
| Welcome picture | 20 (23.3) | 18 (18.0) | 38 (20.4) | 0.786 | 0.375 |
| Personal screen message | 44 (51.2) | 66 (66.0) | 110 (59.1) | 4.212 | 0.040 |
n (%).
Comparison between compliance groups for the perception of pain with EasyPodTM device (N = 186).
|
|
|
|
|
| ||
|---|---|---|---|---|---|---|
| How painful do you find injection with EasyPod | Complete Painless | 36 (41.9) | 48 (48.0) | 84 (45.2) | 1.359 | 0.244 |
| Minimal Pain | 23 (26.7) | 30 (30.0) | 53 (28.5) | |||
| Mild Pain | 25 (29.1) | 19 (19.0) | 44 (23.7) | |||
| Moderate Pain | 1 (1.2) | 2 (2.0) | 3 (1.6) | |||
| Very Painful | 0 (0.0) | 0 (0.0) | 0 (0.0) |
n (%).
Comparison between compliance groups for the most inconvenient feature of the device.
|
|
|
|
|
| |
|---|---|---|---|---|---|
| It has to be kept in the fridge | 34 (39.5) | 56 (56.0) | 90 (48.4) | 13.971 | 0.003 |
| Special batteries | 20 (23.3) | 18 (18.0) | 38 (20.4) | 3.395 | 0.183 |
| Special needles | 22 (25.6) | 27 (27.0) | 49 (26.3) | 3.145 | 0.208 |
| Heavy device | 39 (45.3) | 34 (34.0) | 73 (39.2) | 4.555 | 0.103 |
n (%).