Literature DB >> 35278092

The radiographic outcome after plating for pubic symphysis diastasis: does it matter clinically?

Kuo-Yuan Tseng1, Kai-Cheng Lin1, Shan-Wei Yang2.   

Abstract

INTRODUCTION: Open reduction and internal fixation with plates is the most widespread surgery in traumatic pubic symphysis diastasis. However, implant failure or recurrent diastasis was commonly observed during follow-up. The aim of our study was to evaluate the radiologic findings and clinical outcomes.
MATERIALS AND METHODS: Sixty-five patients with traumatic pubic symphysis diastasis treated with plating between 2008 and 2019 were retrospectively reviewed. The exclusion criteria were a history of malignancy and age under 20 years. Radiographic outcomes were determined by radiograph findings, including pubic symphysis distance (PSD) and implant failure. Clinical outcomes were assessed according to the Majeed score at the final follow-up.
RESULTS: Twenty-eight patients were finally included. Nine patients (32%) experienced implant failure, including four (14%) with screw loosening and five (18%) with plate breakage. Only one patient underwent revision surgery. Postoperatively, a significant increase in PSD was observed at 3 months and 6 months. Postoperative PSD was not significantly different between patients with single plating and double plating, but it was significantly greater in the implant-failure group than in the non-failure group. The Majeed score was similar between patients with single plating and double plating or between the implant-failure group and the non-failure group. Body mass index, number of plates, age, and initial injured PSD were not significantly different between the implant-failure group and the non-failure group. Only a significant male predominance was observed in the implant-failure group.
CONCLUSION: A gradual increase in the symphysis distance and a high possibility of implant failure may be the distinguishing features of traumatic pubic symphysis diastasis fixation. The postoperative symphyseal distance achieved stability after 6 months, even after implant failure. Radiographic outcomes, such as increased symphysis distance, screw loosening, and plate breakage, did not affect clinical functional outcomes.
© 2022. The Author(s).

Entities:  

Keywords:  Functional outcome; Implant failure; Plating; Pubic symphysis diastasis

Year:  2022        PMID: 35278092     DOI: 10.1007/s00402-022-04411-7

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  19 in total

1.  Anterior stabilization in the pubic symphysis separation: a mechanical testing.

Authors:  S Waikakul; K Soparat; T Harnroongroj
Journal:  J Med Assoc Thai       Date:  1999-01

2.  Three-dimensional finite element analysis of several internal and external pelvis fixations.

Authors:  J M García; M Doblaré; B Seral; F Seral; D Palanca; L Gracia
Journal:  J Biomech Eng       Date:  2000-10       Impact factor: 2.097

Review 3.  Damage control orthopaedics in unstable pelvic ring injuries.

Authors:  P V Giannoudis; H C Pape
Journal:  Injury       Date:  2004-07       Impact factor: 2.586

4.  [Percutaneous fixation of pelvic ring disruptions].

Authors:  Xiao-shan Guo; Yong-long Chi
Journal:  Zhonghua Wai Ke Za Zhi       Date:  2006-02-15

5.  Is fixation failure after plate fixation of the symphysis pubis clinically important?

Authors:  Stephen A C Morris; Jeremy Loveridge; David K A Smart; Anthony J Ward; Tim J S Chesser
Journal:  Clin Orthop Relat Res       Date:  2012-08       Impact factor: 4.176

6.  Effects of method of internal fixation of symphyseal disruptions on stability of the pelvic ring.

Authors:  E Varga; T Hearn; J Powell; M Tile
Journal:  Injury       Date:  1995-03       Impact factor: 2.586

7.  Acute Pelvic Fractures: II. Principles of Management.

Authors: 
Journal:  J Am Acad Orthop Surg       Date:  1996-05       Impact factor: 3.020

8.  Open reduction and internal fixation of a traumatic diastasis of the pubic symphysis: one-year radiological and functional outcomes.

Authors:  S E Putnis; R Pearce; U J Wali; M D Bircher; M S Rickman
Journal:  J Bone Joint Surg Br       Date:  2011-01

9.  Internal fixation of traumatic diastasis of pubic symphysis: is plate removal essential?

Authors:  Peter V Giannoudis; Byron E Chalidis; Craig S Roberts
Journal:  Arch Orthop Trauma Surg       Date:  2007-08-23       Impact factor: 3.067

10.  Novel minimally invasive tape suture osteosynthesis for instabilities of the pubic symphysis: a biomechanical study.

Authors:  Adrian Cavalcanti Kußmaul; Fanny Schwaabe; Manuel Kistler; Clara Gennen; Sebastian Andreß; Christopher A Becker; Wolfgang Böcker; Axel Greiner
Journal:  Arch Orthop Trauma Surg       Date:  2021-05-29       Impact factor: 2.928

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.