| Literature DB >> 35272697 |
Devrim Can Sarac1, Bayram Unver2, Vasfi Karatosun3.
Abstract
PURPOSE: This study aimed to investigate validity and reliability of the Timed Up and Go Test (TUG), 10 Meter Walk Test (10MWT), Single Leg Stance Test (SLST), 2 Minute Walk Test (2MWT), and Five Times Sit-to-Stand Test (5xSST) for evaluating balance in patients with total knee arthroplasty (TKA).Entities:
Keywords: Balance; Knee arthroplasty; Performance test; Reliability; Validity
Year: 2022 PMID: 35272697 PMCID: PMC8908580 DOI: 10.1186/s43019-022-00136-4
Source DB: PubMed Journal: Knee Surg Relat Res ISSN: 2234-0726
Characteristics of participants
| Characteristic | Mean ± SD or n (%) |
|---|---|
| Age (years) | 64.07 ± 10.57 |
| Height (cm) | 156.96 ± 8.79 |
| Weight(kg) | 75.74 ± 9.65 |
| BMI (kg/m2) | 31.11 ± 5.39 |
| Gender | |
Female Male | 34 (82.9%) 7 (17.1%) |
| Occupation | |
Employed Unemployed | 14 (34.1%) 27 (65.9%) |
| Marital status | |
Married Single | 35 (85.36%) 6 (14.64%) |
SD standard deviation, n number cm centimeters, kg kilogram, BMI body mass index, m meters
Performance test scores of participants
| Test | Median (IQR) |
|---|---|
| BBS (score) | 54.0 (50.75/55.0) |
| FES-I (score) | 22.0 (17.75/27.25) |
| TUG (sec) | 9.60 (7.87/12.42) |
| 5xSST (sec) | 11.46 (10.03/15.2) |
| SLST (sec) | 10.01 (4.2/17.79) |
| 10MWT (sec) | 9.31 (7.37/11.1) |
| 2MWT (m) | 150.0 (119.25/161.25) |
IQR interquartile range, BBS Berg Balance Scale, FES-I Fall Efficacy Scale-International, TUG Timed Up and Go Test, 10MWT 10 Meter Walk Test, SLST Single Leg Stance Test, 2MWT 2 Minute Walk Test, 5xSST Five Times Sit-to-Stand Test, sec seconds, cm centimeters; m meters
Correlations between performance tests and BBS and FES-I
| BBS | FES-I | |||
|---|---|---|---|---|
| TUG | −0.813 | < 0.01 | 0.692 | < 0.01 |
| 5xSST | −0.765 | < 0.01 | 0.749 | < 0.01 |
| SLST | 0.704 | < 0.01 | −0.540 | < 0.01 |
| 10MWT | −0.737 | < 0.01 | 0.617 | < 0.01 |
| 2MWT | 0.819 | < 0.01 | −0.677 | < 0.01 |
*p < 0.05, Spearman’s correlation coefficient (rho); BBS Berg Balance Scale, FES-I Fall Efficacy Scale-International, TUG Timed Up and Go Test, 5xSST Five Times Sit-to-Stand Test, SLST Single Leg Stance Test, 10MWT 10 Meter Walk Test, 2MWT 2 Minute Walk Test
Test–retest reliability, standard error measurements, and minimal detectable change values of the performance tests
| First evaluation, mean ± SD | Second evaluation, mean ± SD | ICC (95% CI) | SEM | MDC95 | |
|---|---|---|---|---|---|
| TUG (sec) | 10.81 ± 4.5 | 10.71 ± 5.05 | 0.94 (.89–.97) | 1.10 | 3.04 |
| 5xSST (sec) | 13.66 ± 6.33 | 13.14 ± 5.09 | 0.96 (0.92–0.98) | 1.26 | 3.49 |
| SLST (sec) | 13.96 ± 13.62 | 19.47 ± 19.44 | 0.72 (0.47–0.85) | 7.08 | 19.62 |
| 10MWT (sec) | 9.91 ± 3.43 | 9.73 ± 3.08 | 0.97 (0.94–0.98) | 0.59 | 1.63 |
| 2MWT (m) | 143.41 ± 36.85 | 144.08 ± 37.54 | 0.94 (0.90–0.98) | 9.02 | 25.00 |
SD standard deviation, ICC (95% CI) interclass correlation coefficients in 95% confidence interval, SEM standard error measurement, MDC minimal detectable change in 95% confidence interval, TUG Timed Up and Go Test, 10MWT 10 Meter Walk Test, SLST Single Leg Stance Test, 2MWT 2 Minute Walk Test, 5xSST Five Times Sit-to-Stand Test, sec seconds, cm centimeters, m meters