Literature DB >> 3525658

Measuring liver span. Bedside examination versus ultrasound and scintiscan.

B Skrainka, J Stahlhut, C L Fulbeck, F Knight, R A Holmes, J H Butt.   

Abstract

In 75 hospital patients an estimation of liver span was made independently by students (I), fellows (II), and consultants (III). These bedside estimates were made three times at full inspiration in a right parasagittal line one third of the sternal length from the midline by palpation, direct, and indirect percussion. These bedside estimates were compared to each other and to ultrasound in full inspiration in the supine position and to scintiscan in quiet respiration. We found that bedside estimate of liver span by direct percussion was accurate as ultrasound, but that indirect percussion estimate of liver span was inaccurate. Scintiscanning during quiet respiration over-estimates the liver span in comparison to ultrasound. Previous suggestions that clinical estimates of liver span should be abandoned may be in error.

Entities:  

Mesh:

Year:  1986        PMID: 3525658     DOI: 10.1097/00004836-198606000-00013

Source DB:  PubMed          Journal:  J Clin Gastroenterol        ISSN: 0192-0790            Impact factor:   3.062


  2 in total

1.  Evaluation of liver size by physical examination.

Authors:  E J Meidl; J Ende
Journal:  J Gen Intern Med       Date:  1993-11       Impact factor: 5.128

2.  Point-of-care ultrasonography improves the diagnosis of splenomegaly in hospitalized patients.

Authors:  Andrew P J Olson; Bernard Trappey; Michael Wagner; Michael Newman; L James Nixon; Daniel Schnobrich
Journal:  Crit Ultrasound J       Date:  2015-09-17
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.