Literature DB >> 35256346

Comparison of Success Rates of Different Methods of Ultrasound-Guided Radial Artery Cannulation (Short-Axis and Long-Axis Methods) Against the Traditional Palpatory Method: A Prospective Randomized Study.

Mounica Rajasekar1, Senthilkumar Sukumar1, Venkatesh Selvaraj1.   

Abstract

OBJECTIVE: Recent meta-analysis comparing the success rates of various methods of arterial cannulation in adult patients found heterogeneity in the available data. Hence, we did this study to evaluate and compare the success rate of palpatory method with that of ultrasound guided methods of radial artery cannulation. The aim is to compare the first-attempt success rate of the palpatory method with that of ultrasound-guided radial artery cannulation techniques, namely, the short-axis out-of-plane and the long-axis in-plane methods.
METHODS: This is a prospective, randomized, parallel-arm study. Ninety patients aged from 18 to 50 years (presenting for various surgeries requiring radial artery cannulation for invasive blood pressure monitoring or frequent arterial blood gas analysis) were divided into 3 groups. Each group had one of the 3 techniques of radial arterial cannulation, namely palpatory, short-axis ultrasound method, and long-axis ultrasound method. The parameters analyzed were first-attempt success rate, number of attempts needed, cannulation time, need for crossover of technique, and incidence of complications. Multivariate analysis was done with one-way ANOVA, with Tukey's post hoc test. For categorical data, the chi-square test was used. The probability value of .05 was considered as a significant level.
RESULTS: The first-attempt success rate was 76.7% in the long-axis method, 86.7% in the short-axis method, and 56.7% in the palpatory method. The short-axis method has been shown to have a shorter cannulation time, fewer attempts needed for successful cannulation, and lower need for crossover of techniques when the first 2 attempts fail.
CONCLUSIONS: We conclude that the ultrasound-guided short-axis method of radial artery cannulation is associated with higher first-attempt success rate compared to the traditional palpatory method.

Entities:  

Year:  2022        PMID: 35256346      PMCID: PMC9154005          DOI: 10.5152/TJAR.2021.1364

Source DB:  PubMed          Journal:  Turk J Anaesthesiol Reanim        ISSN: 2149-276X


  13 in total

Review 1.  Review of Ultrasound-Guided Radial Artery Catheter Placement.

Authors:  Andrew G Miller; Amy J Bardin
Journal:  Respir Care       Date:  2015-12-15       Impact factor: 2.258

Review 2.  Ageing and vascular ageing.

Authors:  B Jani; C Rajkumar
Journal:  Postgrad Med J       Date:  2006-06       Impact factor: 2.401

3.  Ultrasound guidance versus direct palpation for radial artery catheterization by expert operators: a randomized trial among Canadian cardiac anesthesiologists.

Authors:  Cheryl Peters; Stephan K W Schwarz; Cynthia H Yarnold; Katarina Kojic; Stefan Kojic; Stephen J Head
Journal:  Can J Anaesth       Date:  2015-07-10       Impact factor: 5.063

Review 4.  Radial artery cannulation: a comprehensive review of recent anatomic and physiologic investigations.

Authors:  Marek Brzezinski; Thomas Luisetti; Martin J London
Journal:  Anesth Analg       Date:  2009-12       Impact factor: 5.108

Review 5.  Ultrasound-guided radial artery cannulation in adult and paediatric populations: a systematic review and meta-analysis.

Authors:  Leigh White; Alice Halpin; Marianne Turner; Laurent Wallace
Journal:  Br J Anaesth       Date:  2016-05       Impact factor: 9.166

6.  Comparison between ultrasound guided technique and digital palpation technique for radial artery cannulation in adult patients: An updated meta-analysis of randomized controlled trials.

Authors:  Sulagna Bhattacharjee; Souvik Maitra; Dalim K Baidya
Journal:  J Clin Anesth       Date:  2018-03-22       Impact factor: 9.452

7.  Ultrasound-guided versus palpation-guided radial artery catheterization in adult population: A systematic review and meta-analysis of randomized controlled trials.

Authors:  Homam Moussa Pacha; Fares Alahdab; Yasser Al-Khadra; Amr Idris; Firas Rabbat; Fahed Darmoch; Mohamad Soud; Anwar Zaitoun; Amir Kaki; Sunil V Rao; Chun Shing Kwok; Mamas A Mamas; M Chadi Alraies
Journal:  Am Heart J       Date:  2018-06-19       Impact factor: 4.749

Review 8.  Mechanical factors in arterial aging: a clinical perspective.

Authors:  Michael F O'Rourke; Junichiro Hashimoto
Journal:  J Am Coll Cardiol       Date:  2007-06-18       Impact factor: 24.094

Review 9.  Efficacy of ultrasound-guided radial artery catheterization: a systematic review and meta-analysis of randomized controlled trials.

Authors:  Wan-Jie Gu; Hong-Tao Tie; Jing-Chen Liu; Xian-Tao Zeng
Journal:  Crit Care       Date:  2014-05-08       Impact factor: 9.097

10.  Comparison of Ultrasound-Guided Vs Traditional Arterial Cannulation by Emergency Medicine Residents.

Authors:  Casey Wilson; David Rose; Gabor D Kelen; Veena Billioux; Leah Bright
Journal:  West J Emerg Med       Date:  2020-02-26