Literature DB >> 35255425

Pilot scale microbial fuel cells using air cathodes for producing electricity while treating wastewater.

Ruggero Rossi1, Andy Y Hur2, Martin A Page3, Amalia O'Brien Thomas4, Joseph J Butkiewicz4, David W Jones1, Gahyun Baek1, Pascal E Saikaly5, Donald M Cropek2, Bruce E Logan6.   

Abstract

Microbial fuel cells (MFCs) can generate electrical energy from the oxidation of the organic matter, but they must be demonstrated at large scales, treat real wastewaters, and show the required performance needed at a site to provide a path forward for this technology. Previous pilot-scale studies of MFC technology have relied on systems with aerated catholytes, which limited energy recovery due to the energy consumed by pumping air into the catholyte. In the present study, we developed, deployed, and tested an 850 L (1400 L total liquid volume) air-cathode MFC treating domestic-type wastewater at a centralized wastewater treatment facility. The wastewater was processed over a hydraulic retention time (HRT) of 12 h through a sequence of 17 brush anode modules (11 m2 total projected anode area) and 16 cathode modules, each constructed using two air-cathodes (0.6 m2 each, total cathode area of 20 m2) with the air side facing each other to allow passive air flow. The MFC effluent was further treated in a biofilter (BF) to decrease the organic matter content. The field test was conducted for over six months to fully characterize the electrochemical and wastewater treatment performance. Wastewater quality as well as electrical energy production were routinely monitored. The power produced over six months by the MFC averaged 0.46 ± 0.35 W (0.043 W m-2 normalized to the cross-sectional area of an anode) at a current of 1.54 ± 0.90 A with a coulombic efficiency of 9%. Approximately 49 ± 15 % of the chemical oxygen demand (COD) was removed in the MFC alone as well as a large amount of the biochemical oxygen demand (BOD5) (70%) and total suspended solid (TSS) (48%). In the combined MFC/BF process, up to 91 ± 6 % of the COD and 91 % of the BOD5 were removed as well as certain bacteria (E. coli, 98.9%; fecal coliforms, 99.1%). The average effluent concentration of nitrate was 1.6 ± 2.4 mg L-1, nitrite was 0.17 ± 0.24 mg L-1 and ammonia was 0.4 ± 1.0 mg L-1. The pilot scale reactor presented here is the largest air-cathode MFC ever tested, generating electrical power while treating wastewater.
Copyright © 2022 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biofiltration (BF); Energy from waste; Microbial fuel cell (MFC); Wastewater

Mesh:

Substances:

Year:  2022        PMID: 35255425     DOI: 10.1016/j.watres.2022.118208

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  2 in total

1.  Isolation, Identification and Characteristic Analysis of Plant Endophyte Electrogenic Bacteria Shinella zoogloeoides SHE10.

Authors:  Lijun Ling; Hong Luo; Zibin Li; Caiyun Yang; Mingmei Pang; Yixin Tu; Wenting Cheng; Kunling Jiang; Lu Lu
Journal:  Curr Microbiol       Date:  2022-07-26       Impact factor: 2.343

2.  Simultaneous removal of organic matter and nitrogen compounds by partitioned aeration in a 226 L-scale microbial fuel cell.

Authors:  Taiki Yamane; Naoko Yoshida; Mari Sugioka
Journal:  RSC Adv       Date:  2022-05-18       Impact factor: 4.036

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.