Ion-selective membrane electrodes for clinical use.

U Oesch, D Ammann, W Simon.   

Abstract

We review ion-selective solvent polymeric membrane electrodes for clinical use. The particular requirements that the clinical application set on the membrane are discussed in terms of selectivity, stability, lifetime, and response time. The performance of currently available electrodes is reviewed, with consideration of actual problems that arise in clinical practice.

Mesh:

Substances:

Year:  1986        PMID: 3524901

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  12 in total

1.  Molecular recognition of organic ammonium ions in solution using synthetic receptors.

Authors:  Andreas Späth; Burkhard König
Journal:  Beilstein J Org Chem       Date:  2010-04-06       Impact factor: 2.883

2.  Interference of haemolysis and hyperproteinemia on sodium, potassium, and chloride measurements in canine serum samples.

Authors:  D Bernardini; G Gerardi; B Contiero; M Caldin
Journal:  Vet Res Commun       Date:  2009-09       Impact factor: 2.459

3.  Analysis of interaction between the Arthrobacter sarcosine oxidase and the coenzyme flavin adenine dinucleotide by site-directed mutagenesis.

Authors:  Y Nishiya; T Imanaka
Journal:  Appl Environ Microbiol       Date:  1996-07       Impact factor: 4.792

4.  Elevated serum levels of bromine do not always indicate pseudohyperchloremia.

Authors:  Takayasu Ito; Eiji Ishikawa; Yoshikazu Matsuda; Akiko Tanoue; Mika Fujimoto; Hiroshi Matsuo; Tomohiro Murata; Takuya Hiramoto; Masaaki Ito; Shinsuke Nomura
Journal:  Clin Exp Nephrol       Date:  2010-08-12       Impact factor: 2.801

5.  Covalent immobilization of lipase, glycerol kinase, glycerol-3-phosphate oxidase & horseradish peroxidase onto plasticized polyvinyl chloride (PVC) strip & its application in serum triglyceride determination.

Authors:  Nidhi Chauhan; Jagriti Narang; Chandra Shekhar Pundir
Journal:  Indian J Med Res       Date:  2014-04       Impact factor: 2.375

6.  Impact of light salt substitution for regular salt on blood pressure of hypertensive patients.

Authors:  Carolina Lôbo de Almeida Barros; Ana Luiza Lima Sousa; Brunella Mendonça Chinem; Rafaela Bernardes Rodrigues; Thiago Souza Veiga Jardim; Sérgio Baiocchi Carneiro; Weimar Kunz Sebba Barroso de Souza; Paulo César Brandão Veiga Jardim
Journal:  Arq Bras Cardiol       Date:  2014-11-18       Impact factor: 2.000

Review 7.  Ion-specific nutrient management in closed systems: the necessity for ion-selective sensors in terrestrial and space-based agriculture and water management systems.

Authors:  Matthew Bamsey; Thomas Graham; Cody Thompson; Alain Berinstain; Alan Scott; Michael Dixon
Journal:  Sensors (Basel)       Date:  2012-10-01       Impact factor: 3.576

8.  Flow injection potentiometric assay of hexoprenaline in its pure state, pharmaceutical preparations, and biological samples.

Authors:  Rasha M El-Nashar
Journal:  J Autom Methods Manag Chem       Date:  2008

9.  Synthesis of thiol derivatives of azobenzocrown ethers. The preliminary studies on recognition of alkali metal ions by gold nanoparticles functionalized with azobenzocrown and lipoic acid.

Authors:  Elżbieta Luboch; Mirosław Szarmach; Anna Buczkowska; Ewa Wagner-Wysiecka; Magdalena Kania; Witold Danikiewicz
Journal:  J Incl Phenom Macrocycl Chem       Date:  2015-09-25       Impact factor: 1.633

10.  Sodium, Potassium and Iodine Intake, in A National Adult Population Sample of the Republic of Moldova.

Authors:  Lanfranco D'Elia; Galina Obreja; Angela Ciobanu; Joao Breda; Jo Jewell; Francesco P Cappuccio
Journal:  Nutrients       Date:  2019-11-28       Impact factor: 5.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.