Literature DB >> 3524318

Organ blood flow during high-frequency ventilation at low and high airway pressure in dogs.

F R Gioia, A P Harris, R J Traystman, M C Rogers.   

Abstract

Using the radiolabeled microsphere technique, the authors studied hemodynamic variables and regional blood flow to multiple peripheral organs during conventional positive-pressure ventilation (CV) and high-frequency ventilation (HFV) at low and high mean airway pressure (Paw). Twenty supine anesthetized, paralyzed dogs were ventilated using CV (14-16 breaths/min) and HFV (rate = 10 Hz) in random order. In the first group (low Paw, n = 10), Paw was maintained at 3 cmH2O during CV and HFV. In the second group (high Paw, n = 10), Paw was increased to 13 cmH2O during CV and HFV. Pulmonary capillary wedge pressure and right atrial pressure remained constant during low and high Paw trials. No differences in heart rate, systemic arterial pressure, intracranial pressure, or cardiac output were noted during CV and HFV within the low and high Paw groups. In addition, blood flow to multiple peripheral organs during CV and HFV remained constant within each Paw group, except for a small decrease in cerebellar blood flow during HFV at high Paw trials showed a significant decrease in hepatic arterial and outer kidney cortical flow at high Paw. Total cerebral blood flow was decreased at high Paw, as were regional flows to diencephalon, midbrain, pons, medulla, and cerebellum. However, these differences were not attributable to differences in cerebral perfusion pressure or intracranial pressure, and cerebral oxygen delivery was not different between high Paw and low Paw groups. It is concluded that under conditions of similar Paw in anesthetized dogs, HFV does not significantly alter hemodynamic patterns or regional circulation relative to CV.

Entities:  

Mesh:

Year:  1986        PMID: 3524318     DOI: 10.1097/00000542-198607000-00008

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  4 in total

1.  Does PEEP impair the hepatic outflow in patients following liver transplantation?

Authors:  Fuat H Saner; Goran Pavlaković; Yanli Gu; Nils R Fruhauf; Andreas Paul; Arnold Radtke; Silvio Nadalin; Massimo Malagó; Christoph E Broelsch
Journal:  Intensive Care Med       Date:  2006-08-29       Impact factor: 17.440

2.  Determination of comprehensive arterial blood inflow in abdominal-pelvic organs: impact of respiration and posture on organ perfusion.

Authors:  Takuya Osada; Hiroyasu Nagata; Norio Murase; Ryotaro Kime; Toshihito Katsumura
Journal:  Med Sci Monit       Date:  2011-02

3.  Hepatic effects of lung-protective pressure-controlled ventilation and a combination of high-frequency oscillatory ventilation and extracorporeal lung assist in experimental lung injury.

Authors:  Markus Kredel; Ralf M Muellenbach; Amélie Johannes; Joerg Brederlau; Norbert Roewer; Christian Wunder
Journal:  Med Sci Monit       Date:  2011-10

4.  Physiological aspects of the determination of comprehensive arterial inflows in the lower abdomen assessed by Doppler ultrasound.

Authors:  Takuya Osada
Journal:  Cardiovasc Ultrasound       Date:  2012-03-26       Impact factor: 2.062

  4 in total