| Literature DB >> 35242513 |
Rawan M Khalaf1, Abdullazez A Almudhi2.
Abstract
The aim of this study was to determine the effect of vitamin D deficiency on the RANKL/OPG ((Receptor Activator of Nuclear Factor Kappa B Ligand/Osteoprotegerin) ratio in the serum blood levels. Sixteen Wistar rats were divided into 2 groups: a control group (C) and an experimental group (E). The group C comprised of rats with average vitamin D levels, while vitamin D deficiency was induced in those of group E. A test period of 21 days was employed wherein two serum blood samples were obtained, at the baseline (day 0) and at day 21. Changes in RANKL andOPG levels were measured using Enzyme-linked immunosorbent assay (ELISA) kits. A statistically significant decrease of serum RANKL concentration and RANKL/OPG ratio on day 21 was seen in the experimental group compared to the control group. The serum RANKL levels and RANKL/OPG ratio in rats, were negatively affected by the deficiency of vitamin D.Entities:
Keywords: Calcium; OPG; PTH; Phosphorus, ELISA; RANKL; RANKL/OPG ratio; Vitamin D deficiency
Year: 2022 PMID: 35242513 PMCID: PMC8886034 DOI: 10.1016/j.jobcr.2022.02.004
Source DB: PubMed Journal: J Oral Biol Craniofac Res ISSN: 2212-4268
Assay Kits used in the study.
| Name of Kit | Product Code | Purpose | Manufacturer |
|---|---|---|---|
| Phosphorus Colorimetric Assay Kit (Phospho-molybdate method) | E-BC-K245 | Serum Phosphorus detection | Elabscience biotechnology Inc, China |
| Calcium Assay Kit, (With standard) | E-BC-K103 | Serum Calcium detection | Elabscience biotechnology Inc, China |
| Rat I-PTH (Intact Parathormone) ELISA Kit | E-EL-R0535 96T | Serum PTH detection | Elabscience biotechnology Inc, China |
| Rat RANKL (Receptor Activator of Nuclear Factor Kappa B Ligand) ELISA kit | E-EL-R0841 96T | Serum RANKL detection | Elabscience biotechnology Inc, China |
| Rat OPG (Osteoprotegerin) ELISA Kit | E-EL-R0050 96T | Serum OPG detection | Elabscience biotechnology Inc, China |
Fig. 1The enzyme-substrate reaction terminated by adding Stop Solution and appears yellow in color.
Fig. 2BioTek Synergy HT Microplate reader (Winooski, VA, USA).
Differences in the test measures at baseline and Day 21.
| Group | Parameter | Day 0 | Day 21 | t | Sig | ||
|---|---|---|---|---|---|---|---|
| Mean | SD | Mean | SD | ||||
| 160.875 | 15.21688 | 176.125 | 18.48117 | −2.148 | 0.069** | ||
| 1876.93 | 1699.26 | 1044.12 | 573.30 | 1.454 | 0.189 | ||
| 1436.56 | 233.33 | 1489.93 | 924.97 | −0.175 | 0.866 | ||
| 1.2425 | 1.10651 | 1.7719 | 2.76531 | −0.051 | 0.666 | ||
| 51.6 | 8.64 | 20.9 | 3.75 | 14.916 | <0.001** | ||
| 2871 | 1899.57 | −1089.62 | 459.08 | 6.882 | <0.001** | ||
| 1181.66 | 176.86 | 1917.95 | 488.00 | −3.586 | 0.009** | ||
| 2.344 | 1.41 | −0.5812 | 0.229 | 6.423 | <0.001** | ||
** Differences significant at p < 0.05.
Calculated using the paired t-test.
Comparison of test variables between test and control group at day 21.
| Group | Mean | Std. Deviation | Std. Error Mean | t | Sig | |
|---|---|---|---|---|---|---|
** Differences significant at p < 0.05.
Calculated using the independent samples t-test.