Literature DB >> 35241879

The use of mobile bearing TKA in valgus deformities - A clinical study.

Gianluca Castellarin1, Edoardo Bori2, Mathieu Biava2, Giacomo Talevi2, Bernardo Innocenti2.   

Abstract

BACKGROUND: The number of patients presenting valgus deformities undergoing total knee arthroplasty (TKA) represents approximately 10% of the total number of TKAs performed: the presence of valgus deformity requires the implant to have proper alignment, stability and balance to achieve successful clinical outcomes, especially for knees with high coronal deformities, but these have proven to be difficult goals to achieve and therefore the use of constrained prostheses is often recommended for these cases. However, even though the use of unconstrained mobile bearing for severe knee deformities is rare, it has been shown to give successful outcomes and therefore the aim of this study is to evaluate whether this surgical technique can achieve satisfactory clinical results and correct alignment, as well as good patient satisfaction.
METHODS: This study presents the results of 69 TKA performed with cemented mobile bearing implants by a single surgeon on knee affected by valgus deformities. Asymmetric inserts were adopted for all the implants and an alignment surgical tool, dedicated for valgus patients, was used during the operation. Angles of valgus, WOMAC surveys and Numeric Rating Scale for pain were recorded to evaluate the results of the operations.
RESULTS: A total of 67 pre-op WOMAC questionnaire surveys were collected, with the mean result of this evaluation being 15.9 points. The Numeric Rating Scale for pain had an average of 2.2 for 68 tests. The deformities were corrected from a mean total preoperative valgus angle of 12.5° to a postoperative valgus deformity average of 0.6°. During follow-up, only one patient had serious complications due to the rupture of the extensor apparatus following a domestic accident involving falling. Further 10 patients have mild complications related to injuries such as pain of varying intensity, burning, or swelling of the knee. The level of satisfaction from 0 to 10 (0 not at all satisfied and 10 perfectly satisfied) had an average score of 7.7.
CONCLUSIONS: The surgical approach presented, involving a less constrained model if compared to the ones usually chosen, allowed to achieve correct alignment and high patient satisfaction using mobile bearing implants on valgus knee deformities; further patient follow-up will be performed to evaluate long-term outcomes, but the results achieved already represent a significative finding.
© 2021 Professor P K Surendran Memorial Education Foundation. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cemented; Mobile bearing; Novel surgical technique; Total knee arthroplasty; Valgus deformity

Year:  2021        PMID: 35241879      PMCID: PMC8858731          DOI: 10.1016/j.jor.2021.12.002

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  26 in total

Review 1.  Knee replacement surgery for osteoarthritis: effectiveness, practice variations, indications and possible determinants of utilization.

Authors:  P Dieppe; H D Basler; J Chard; P Croft; J Dixon; M Hurley; S Lohmander; H Raspe
Journal:  Rheumatology (Oxford)       Date:  1999-01       Impact factor: 7.580

2.  The effect of varus and valgus deformity on results of cementless mobile bearing TKA.

Authors:  R Barry Sorrells; Jeffrey A Murphy; Kate C Sheridan; Ray C Wasielewski
Journal:  Knee       Date:  2007-06-11       Impact factor: 2.199

Review 3.  Current surgical strategies for total arthroplasty in valgus knee.

Authors:  Dimitrios Nikolopoulos; Ioannis Michos; George Safos; Petros Safos
Journal:  World J Orthop       Date:  2015-07-18

4.  Total knee arthroplasty for severe valgus deformity. Five to fourteen-year follow-up.

Authors:  Mark Elkus; Chitranjan S Ranawat; Vijay J Rasquinha; Sushrut Babhulkar; Roberto Rossi; Amar S Ranawat
Journal:  J Bone Joint Surg Am       Date:  2004-12       Impact factor: 5.284

5.  High Incidence of Tibial Component Loosening After Total Knee Arthroplasty Using Ceramic Titanium-Nitride-Coated Mobile Bearing Prosthesis in Moderate to Severe Varus Deformity: A Matched-Pair Study Between Ceramic-Coated Mobile Bearing and Fixed Bearing Prostheses.

Authors:  Sang Jun Song; Hyun Woo Lee; Dae Kyung Bae; Cheol Hee Park
Journal:  J Arthroplasty       Date:  2019-11-27       Impact factor: 4.757

6.  Rotating platform spinouts with cruciate-retaining mobile-bearing knees.

Authors:  David A Fisher; Thomas L Bernasek; Rajeev D Puri; Mary L Burgess
Journal:  J Arthroplasty       Date:  2011-05-06       Impact factor: 4.757

7.  Does low-constraint mobile bearing knee prosthesis give satisfactory results for severe coronal deformities? A five to twelve year follow up study.

Authors:  Jaroslaw Czekaj; Camdon Fary; Thierry Gaillard; Sebastien Lustig
Journal:  Int Orthop       Date:  2017-04-11       Impact factor: 3.075

8.  Health-related quality of life after total knee or hip replacement for osteoarthritis: a 7-year prospective study.

Authors:  O Bruyère; O Ethgen; A Neuprez; B Zégels; Ph Gillet; J-P Huskin; J-Y Reginster
Journal:  Arch Orthop Trauma Surg       Date:  2012-07-28       Impact factor: 3.067

9.  Unconstrained total knee arthroplasty in significant valgus deformity: a modified surgical technique to balance the knee and avoid instability.

Authors:  R Pagoti; S O'Brien; E Doran; D Beverland
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-28       Impact factor: 4.342

10.  Severe varus and valgus deformities treated by total knee arthroplasty.

Authors:  T Karachalios; P P Sarangi; J H Newman
Journal:  J Bone Joint Surg Br       Date:  1994-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.