Literature DB >> 35232991

Synthetic correlated diffusion imaging hyperintensity delineates clinically significant prostate cancer.

Alexander Wong1,2, Hayden Gunraj3, Vignesh Sivan4, Masoom A Haider5,6.   

Abstract

Prostate cancer (PCa) is the second most common cancer in men worldwide and the most frequently diagnosed cancer among men in more developed countries. The prognosis of PCa is excellent if detected at an early stage, making early screening crucial for detection and treatment. In recent years, a new form of diffusion magnetic resonance imaging called correlated diffusion imaging (CDI) was introduced, and preliminary results show promise as a screening tool for PCa. In the largest study of its kind, we investigate the relationship between PCa presence and a new variant of CDI we term synthetic correlated diffusion imaging (CDI[Formula: see text]), as well as its performance for PCa delineation compared to current standard MRI techniques [T2-weighted (T2w) imaging, diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) imaging] across a cohort of 200 patient cases. Statistical analyses reveal that hyperintensity in CDI[Formula: see text] is a strong indicator of PCa presence and achieves strong delineation of clinically significant cancerous tissue compared to T2w, DWI, and DCE. These results suggest that CDI[Formula: see text] hyperintensity may be a powerful biomarker for the presence of PCa, and may have a clinical impact as a diagnostic aid for improving PCa screening.
© 2022. The Author(s).

Entities:  

Mesh:

Substances:

Year:  2022        PMID: 35232991      PMCID: PMC8888633          DOI: 10.1038/s41598-022-06872-7

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


Introduction

Prostate cancer (PCa) is the second most common form of cancer in men worldwide and the most frequently diagnosed cancer among men in more developed countries, with roughly 1.4 million new cases in 2020[1]. While the overall 5-year survival rate for prostate cancer is very high, prognosis is poor for patients with distant metastases outside of the prostate[2,3]. As such, early diagnosis of PCa is critical for improving the treatment of patients with PCa. Clinical screening for PCa has traditionally involved the use of prostate-specific antigen (PSA) screening, with high PSA levels used as an indicator of PCa[4]. Unfortunately, studies have shown that PSA screening has led to a significant over-diagnosis of men suspected of PCa, resulting in over-treatment that carries significant risks[5,6]. While diagnostic imaging has been increasingly prevalent for PCa screening and diagnosis, one can argue that there is currently no universally accepted method for screening and diagnosing prostate cancer via imaging. Transrectal ultrasound (TRUS) is routinely used to guide prostate biopsy; however, its use for PCa screening and diagnosis is limited due to the fact that PCa tumors are often isoechoic and thus cannot be delineated from surrounding tissue via TRUS. As a result, PCa screening and diagnosis using TRUS has low sensitivity and specificity[7]. PCa screening and diagnosis using positron emission tomography (PET) has also been explored, with several tracers showing promise for delineating cancerous and non-cancerous tissue in the prostate gland[8-11]. Unfortunately, the high cost of PET scanning makes it impractical as diagnostic tool early in the screening pathway. Magnetic resonance imaging (MRI) has grown significantly in prevalence for the purpose of PCa screening, with wide acceptance of the standardized Prostate Imaging Reporting and Data System (PI-RADS)[12]. T2-weighted MRI (T2w) has been well-studied for PCa screening and diagnosis[13-16], where potentially cancerous regions are characterized by signal hypointensity, and is considered the primary determining modality for the transition zone (TZ) in PI-RADS[12,16]. However, T2w signal hypointensity in the peripheral zone (PZ) of the prostate gland can also be associated with a number of non-cancerous abnormal conditions such as inflammation, fibrosis, and hemorrhage[17,18], leading to false positives if T2w was the sole method used. To improve diagnostic accuracy when using MRI for PCa screening and diagnosis, two complementary MRI techniques have been leveraged for improved PCa screening alongside T2w: (1) diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) calculated from DWI, and (2) dynamic contrast-enhanced (DCE) imaging[17]. These techniques, when used together with T2w, form a multi-parametric MRI (mpMRI) strategy to overcome the shortcomings of each modality. However, the need to interpret several modalities can increase interpretation challenges, resulting in increased inter- and intra-observer variability. Recently, a new MRI technique called correlated diffusion imaging (CDI)[19] was proposed for improving PCa diagnosis. Preliminary studies demonstrated the potential of CDI for delineating between cancerous and non-cancerous tissue[19,20]. However, the scope of these studies are limited in terms of patient cohort size and diversity (e.g., a patient cohort of 20 patient cases[19]). Furthermore, a number of limitations exist in CDI as first introduced with respect to signal-to-noise ratio (SNR) and acquisition time, as well as SI variability amongst inter-patient and intra-patient acquisitions. The contribution of this study are twofolds. First, this study represents the largest study of its kind for exploring the relationship between PCa presence and CDI signal hyperintensity across a cohort of 200 patient cases. Second, we introduce an extended variant of CDI we term synthetic correlated diffusion imaging (CDI), which leverages a hybrid of native and synthetic diffusion signal acquisitions and signal calibration for greater consistency in dynamic range across machines and protocols. We compare the performance of CDI for PCa delineation to current standard MRI techniques (T2w imaging, DWI, and DCE imaging). This study aims to provide insights on the potential clinical impact of CDI as a diagnostic aid for improving PCa screening.

Results

In this study, we investigated the efficacy of CDI from two different perspectives. First, we studied the relationship between CDI SI and the presence of PCa, both clinically significant PCa (csPCa) tissue and clinically insignificant PCa (insPCa) tissue. Consistent with the contemporary concept of csPCa versus insPCa[21], csPCa tissue is defined as tissue with a Gleason score greater than or equal to 7 (Gleason Grade Groups 2-5 according to the International Society of Urological Pathology) while insPCa tissue is defined as tissue with a Gleason score less than 7 (Gleason Grade Group 1). Second, we studied the performance of CDI in delineating csPCa tissue and insPCa tissue from healthy tissue.

Relationship between CDI SI and the presence of PCa

Figure 1 shows the histogram analysis conducted to study the distribution of CDI SI, T2w SI, DWI-derived ADC values, and DCE-derived (volume transfer constant) values for healthy tissue, csPCa tissue, and insPCa tissue. A number of observations can be made from this histogram analysis. First, CDI SI hyperintensity is clearly exhibited in the presence of csPCa, with the clinical significance of PCa (from healthy tissue to csPCa tissue) progressively increasing with the CDI SI. This observation means that not only can CDI SI hyperintensity be a good indicator for the presence of PCa, but can also be a good risk assessment and treatment planning tool for quantitatively assessing the degree of disease severity. Second, it can be observed that there is noticeably lower overlap between the CDI SI distributions of csPCa tissue and insPCa tissue when compared to that of T2w SI, DWI-derived ADC values, and DCE-derived values. More specifically, the T2w SI distributions of healthy tissue, csPCa tissue, and insPCa tissue all have considerable overlap, while the value distributions of insPCa tissue and csPCa tissue have greater overlap for both and ADC values. This observation means that CDI can potentially be a good clinical decision support tool for clinicians when compared to the current standard MRI techniques in determining the course of action for a patient, be it watchful waiting, active surveillance, or immediate treatment.
Figure 1

Histogram analysis of CDI SI, T2w SI, DWI-derived ADC values, and DCE-derived values for healthy tissue, insPCa tissue, and csPCa tissue.

Histogram analysis of CDI SI, T2w SI, DWI-derived ADC values, and DCE-derived values for healthy tissue, insPCa tissue, and csPCa tissue.

Delineation between PCa tissue and healthy tissue based on quantitative analysis

Figure 2 shows the ROC curves for studying the performance of CDI SI, CDI (tuned CDI) SI, T2w SI, DWI-derived ADC values, and DCE-derived values for delineating csPCa tissue and insPCa tissue from healthy tissue. Differences in area under the curve (AUC) between modalities were assessed for statistical significance using the formulation proposed by Hanley and McNeil[22], with the results of these tests given in Supplementary Table 1.
Figure 2

ROC curves for studying the performance of CDI SI, CDI SI, T2w SI, DWI-derived ADC values, and DCE-derived values for delineating csPCa tissue and insPCa tissue from healthy tissue.

A number of observations can be made from this ROC analysis. First, it can be observed that CDI SI and CDI SI achieve noticeably higher AUC for delineating between csPCa tissue and healthy tissue when compared to the current standard MRI techniques, with DWI-derived ADC values achieving the next highest AUC (lower by 0.0308 when compared to CDI SI, ). T2w and DCE-derived values achieve significantly lower AUC compared to the other techniques (lower by as much as 0.2037 when compared to CDI SI, ). When comparing CDI SI and CDI SI, it can be seen that CDI SI achieves 0.0022 higher AUC () when compared to CDI SI, thus illustrating the efficacy of CDI coefficient optimization where applicable. Second, it can be observed that CDI SI and CDI SI achieve significantly greater delineation between csPCa and insPCa tissue when compared to current standard MRI techniques, with DWI-derived ADC values, T2w, and DCE-derived values achieving 0.0612 (), 0.2017 (), and 0.1344 () lower AUC when compared to CDI SI, respectively. Here, the difference in delineation performance between csPCa and insPCa tissue for CDI SI and CDI SI is not significant (). Third, it can be observed that CDI SI and CDI SI achieve noticeably higher AUC for delineating between csPCa tissue and other tissue when compared to the current standard MRI techniques, with DWI-derived ADC values achieving the next highest AUC (lower by 0.0314 when compared to CDI SI, ). T2w and DCE-derived values achieve significantly lower AUC compared to the other techniques (lower by as much as 0.2032 when compared to CDI SI, ). When comparing CDI SI and CDI SI, it can be seen that CDI SI achieves 0.0021 higher AUC () when compared to CDI SI, thus again illustrating the efficacy of CDI coefficient optimization where applicable. Fourth, it can be observed that CDI SI and CDI SI achieve noticeably higher AUC for delineating between PCa tissue (both csPCa and insPCa) and healthy tissue when compared to the current standard MRI techniques, with DWI-derived ADC values achieving the next highest AUC (lower by 0.0151 when compared to CDI SI, ). T2w and DCE-derived values achieve significantly lower AUC compared to the other techniques (lower by as much as 0.1510 when compared to CDI SI, ). When comparing CDI SI and CDI SI, it can be seen that CDI SI achieves 0.0063 higher AUC () when compared to CDI SI, thus again illustrating the efficacy of CDI coefficient optimization where applicable. ROC curves for studying the performance of CDI SI, CDI SI, T2w SI, DWI-derived ADC values, and DCE-derived values for delineating csPCa tissue and insPCa tissue from healthy tissue.

Clinical interpretation

Figure 3a, b shows the T2w and overlays of DWI-derived ADC, DCE-derived , and CDI for two patient cases with csPCa in the PZ. In Fig. 3a, it can be observed that T2w shows no contrast between csPCa tissue and healthy tissue, while exhibits strong contrast for a smaller portion within the csPCa tumor. ADC shows good contrast between the csPCa tumor and some of the surrounding healthy tissue, but exhibits ADC values similar to the tumor in different small regions within the TZ, including an adjacent region above the tumor which is indistinguishable from the tumor itself. CDI shows strong contrast for the entire csPCa tumor from the rest of the healthy tissue.
Figure 3

T2w images with overlays of lesion boundaries, DWI-derived ADC, DCE-derived , and CDI for six patient cases. (a, b) Two patients with csPCa in the PZ. (c, d) Two patients with csPCa in the TZ. (e) A patient with csPCa in the PZ and insPCa in the TZ. (f) A patient with csPCa in the AS and insPCa in the PZ.

In Fig. 3b, it can be observed that T2w shows poor contrast between csPCa tissue and healthy tissue, while exhibits poor contrast between the csPCa tumor and healthy tissue. ADC shows good contrast between the csPCa tumor and surrounding healthy tissue, but exhibits ADC values similar to the tumor in another small region within the PZ that was not identified as PCa tissue. CDI shows strong contrast for the entire csPCa tumor from the rest of the healthy tissue. Figure 3c, d shows the T2w and overlays of DWI-derived ADC, DCE-derived , and CDI for two patient cases with csPCa in the TZ. In Fig. 3c, it can be observed that T2w shows no contrast between csPCa tissue and healthy tissue. exhibits mild contrast in a small region within the csPCa tumor, but strong contrast in a healthy tissue region that is not associated with csPCa. ADC shows strong contrast for the csPCa tumor from surrounding tissue, but exhibits ADC values similar to other regions within the PZ that were not identified as PCa tissue via histopathology validation. CDI shows strong contrast for the entire csPCa tumor from the rest of the healthy tissue. In Fig. 3d, it can be observed that T2w shows no contrast between csPCa tissue and healthy tissue, while , ADC, CDI all exhibit strong contrast between csPCa tissue and healthy tissue. Figure 3e shows the T2w and overlays of DWI-derived ADC, DCE-derived , and CDI for a patient with csPCa in the PZ and insPCa in the TZ. It can be observed that T2w shows no contrast between the csPCa tumor and healthy tissue, and poor contrast between the insPCa tumor and healthy tissue. exhibits no contrast between the csPCa tumor and healthy tissue, and strong contrast for a small portion of the insPCa tumor. ADC shows strong contrast between the csPCa tumor and surrounding healthy tissue and good contrast between the insPCa tumor and surrounding healthy tissue. However, ADC exhibits similar values for both the csPCa and insPCa tumors, as well as ADC values similar to the tumors in small regions within the TZ that were not identified as PCa tissue. CDI show the strongest contrast between the csPCa tumor and healthy tissue amongst the techniques, and shows good contrast between the insPCa tumor and healthy tissue. Furthermore,CDI provides greater contrast between the csPCa tumor and insPCa tumor than ADC. Figure 3f shows the T2w and overlays of DWI-derived ADC, DCE-derived , and CDI for a patient with csPCa in the anterior stroma (AS) and insPCa in the PZ. It can be observed that T2w shows poor contrast between the csPCa tumor and healthy tissue, with T2w SI of the csPCa tumor being similar to healthy tissue in the TZ. T2w also shows good contrast between the insPCa tumor and healthy tissue, although T2w SI of the insPCa tumor is similar to healthy tissue in the TZ. Furthermore, the T2w SI of the csPCa tumor is very similar to that of the insPCa tumor. exhibits no contrast between the csPCa tumor and healthy tissue and no contrast between the insPCa tumor and healthy tissue. Furthermore, exhibits contrast in healthy tissue in the TZ that is not identified as PCa. ADC shows poor contrast between the csPCa tumor and surrounding healthy tissue and good contrast between the insPCa tumor and surrounding healthy tissue. CDI show the strongest contrast between the csPCa tumor and healthy tissue amongst the techniques, and shows good contrast between the insPCa tumor and healthy tissue. Furthermore, CDI provides greater contrast between the csPCa tumor and insPCa tumor than ADC. T2w images with overlays of lesion boundaries, DWI-derived ADC, DCE-derived , and CDI for six patient cases. (a, b) Two patients with csPCa in the PZ. (c, d) Two patients with csPCa in the TZ. (e) A patient with csPCa in the PZ and insPCa in the TZ. (f) A patient with csPCa in the AS and insPCa in the PZ.

Discussion

In this study, we hypothesised that there is a strong relationship between SI of CDI and the presence of PCa, and the experimental results support this hypothesis. Results across a cohort of 200 patient cases with histopathology validation showed that hyperintensity in CDI provides a strong indicator of the presence of csPCa. Furthermore, CDI achieves strong delineation of clinically significant cancerous tissue and healthy tissue (AUC exceeding 0.918 and 0.916 for CDI and CDI, respectively), which is noticeably higher than current standard techniques for prostate screening such as T2w, DWI, and DCE. In general, CDI also shows fewer false positive regions compared to the other techniques. These results suggest that the use of CDI may have a clinical impact as a diagnostic aid for improving PCa screening. To improve diagnostic accuracy when using MRI for PCa screening and diagnosis, DWI is often used alongside T2w, with DWI being the primary determining modality for the PZ in PI-RADS[12]. In DWI, pairs of opposing magnetic field gradient pulses are applied in the imaging sequence to obtain sensitivity to the Brownian motion of water molecules in tissues[23,24]. Therefore, given the presumed higher cellular density of cancerous tissue compared to non-cancerous tissue, potentially cancerous regions would exhibit markedly reduced ADC[12,24] due to restricted diffusion. Despite its considerable promise[25-29], the use of DWI for PCa screening and diagnosis remains a challenge due to considerable ADC variability depending on the strength, duration, and timing of the applied diffusion gradient pulses used in the DWI pulse sequences, thus necessitating tuning of these parameters. This is further complicated by significant overlap in ADC between stromal benign prostatic hyperplasia (BPH), anterior fibromuscular stroma (AFMS), central zone (CZ) tissue, and PCa[30,31]. Another well-established modality leveraged to improve diagnostic accuracy when using MRI for PCa screening and diagnosis is DCE imaging[32]. Here, a contrast agent (low molecular-weight gadolinium chelate) is injected intravenously, and T1-weighted MRI (T1w) is acquired before, during, and after the injection. Given the increased permeability of the tumor vessels, potentially cancerous regions would exhibit a high volume transfer constant between blood plasma and the extravascular extra-cellular space (denoted by ). The use of DCE for PCa screening and diagnosis remains a challenge due to sensitivity to patient motion, lack of specificity[32], and additional acquisition complexities such as cost and process overhead due to the use of an agent. As such, DWI, T2w, and DCE are frequently used together in the form of mpMRI to overcome the shortcomings of each modality; however, the need to interpret multiple modalities also increases the difficulty in interpretation, leading to increased inter- and intra-observer variability. To address the aforementioned shortcomings of DWI and ADC maps for PCa screening and diagnosis, a new diffusion MRI modality was recently introduced in the form of CDI[19]. In CDI, a series of pulse sequences with different gradient pulse strengths and timings are used to probe water molecules with different degree of Brownian motion in the tissues within a local volume. Signal mixing is then performed on the signal acquisitions captured using these pulse sequences to determine the joint correlation of the acquisitions within a local volume. As such, CDI leverages the distribution of water molecules with different degrees of Brownian motion in the tissues within the local volume to delineate between cancerous tissue (indicated by signal hyperintensity due to a wider spread in the distribution of water molecules with varying degrees of Brownian motion within a local volume) and non-cancerous tissue (indicated by lower relative intensity due to a tighter distribution of water molecules with a similar degree of Brownian motion within a local volume). While preliminary studies have shown that CDI holds considerable promise of achieving greater signal delineation between cancerous and non-cancerous tissue when used as a standalone diagnostic imaging method[19] and when used in combination with T2w and DWI[20], these studies are rather limited in scope as the patient study sizes and patient diversity was relatively small. Furthermore, CDI as it was originally investigated has several limitations associated with acquisition time and SNR-associated restrictions, and variability in SI amongst inter-patient and intra-patient acquisitions. As such, a comprehensive study with a significantly larger patient size as well as extensions to CDI to address the aforementioned limitations is highly desired to achieve a thorough investigation and evaluation on the relationship between signal hyperintensity in CDI and presence of PCa, which was the basis of this study. In conclusion, our results in this study support the hypothesis that the use of CDI can be an effective tool for PCa screening and diagnosis, although additional studies are needed before adoption for routine clinical use. Furthermore, given the promising results, we aim to investigate the relationship of CDI SI and the presence of other forms of cancer such as breast cancer, gastric cancer, and glioblastoma.

Methods

Imaging protocol

To study the relationship between CDI SI and PCa, a cohort of 200 patient cases with histopathology validation acquired at Radboud University Medical Centre (Radboudumc) in the Prostate MRI Reference Center in Nijmegen, The Netherlands[33] were used in this study. Notably, findings with a PI-RADS score of 1 or 2 were not biopsied and were considered clinically insignificant. Table 1 summarizes the demographic, MR scanner, and clinical significance variables of the patient cohort used in this study. The patients in this cohort ranged in age from 37-78 years, with a median age of 64 years. All acquisitions were performed using a Siemens MAGNETOM Trio 3.0T machine or a Siemens MAGNETOM Skyra 3.0T machine, and were reviewed by or performed under the supervision of an expert radiologist with over 20 years of experience interpreting prostate MRI[33].
Table 1

Summary of demographic, MR scanner, and clinical significance variables of the patient cohort used in this study. Age and MR scanner statistics are expressed on a patient level, while clinical significance statistics are expressed on a tumor level.

Age
 30–393 (1.5%)
 40–495 (2.5%)
 50–5945 (22.5%)
 60–69112 (56%)
 70–7935 (17.5%)
MR Scanner (Siemens MAGNETOM)
 Skyra 3.0T195 (97.5%)
 Trio 3.0T5 (2.5%)
Clinical significance (Gleason Score)
 csPCa (GS \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\ge$$\end{document} 7)76 (25.4%)
 insPCa (GS < 7 or PI-RADS[12] \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\le$$\end{document} 2)223 (74.6%)
A single-shot echo-planar sequence was used for axial DWI acquisitions, with TR ranging from 2500 to 3300 ms with a median of 2700 ms and TE ranging from 63 to 81 ms with a median of 63 ms. The in-plane resolution of the acquisitions was 2 mm with slice thickness ranging from 3 to 4.5 mm with a median of 3 mm. The display field of view (DFOV) ranged from to  cm with a median of  cm, and images were acquired at b-values of , , and . To compare the performance of CDI for PCa delineation with current standard MRI techniques, ADC maps were also obtained from DWI acquisitions. Axial T2w acquisitions were also obtained as a reference of comparison, and were performed using a turbo spin-echo sequence with TR ranging from 3880 to 7434.8 ms with a median of 5660 ms and TE ranging from 101 to 112 ms with a median of 104 ms. The in-plane resolution of the acquisitions ranged from 0.3 to 0.6 mm with a median of 0.5 mm and slice thickness ranged from 3 to 4.5 mm with a median of 3 mm. The DFOV ranged from  cm to  cm with a median of  cm. Finally, axial DCE imaging was conducted with a turbo flash gradient-echo sequence, with TR ranging from 3.72 to 36 ms with a median of 36 ms and TE ranging from 1.41 to 1.84 ms with a median of 1.41 ms. The in-plane resolution of the acquisitions ranged from 1.3 to 1.8 mm with a median of 1.5 mm, slice thickness ranged from 3 to 5 mm with a median of 3.5 mm, and the temporal resolution was 3.5 s. The DFOV ranged from  cm to  cm with a median of  cm. Maps of the pharmacokinetic parameter were obtained from the DCE series. PCa, whole gland, transition, and PZ annotations for all patient acquisitions in this cohort were used in this study, with the annotation being performed by two radiology residents and two experienced board-certified radiologists (working in pairs) at the University of Naples Federico II, Naples, Italy[34]. Clinical interpretation of CDI, T2w, ADC, and was conducted in this study by an expert radiologist with over 20 years of experience interpreting prostate MRI (MAH). Summary of demographic, MR scanner, and clinical significance variables of the patient cohort used in this study. Age and MR scanner statistics are expressed on a patient level, while clinical significance statistics are expressed on a tumor level.

Synthetic correlated diffusion imaging

In this study, an extended variant of CDI we term CDI is introduced. The first key distinguishing aspect of CDI when compared to CDI is the introduction of synthetic signal acquisitions alongside native signal acquisitions to reduce acquisition time, allow existing clinical imaging protocols and pulse sequences that are routine in mpMRI imaging sessions to be used, as well as overcome SNR limitations and distortion limitations faced by CDI, particularly under gradient pulse configurations with longer echo times. The second key distinguishing aspect of CDI when compared to CDI is the introduction of signal calibration into the signal mixing procedure of CDI to allow for greater consistency in the resulting SI dynamic range across machines and protocols. This signal calibration thus addresses the issue associated with CDI with respect to large variability in SI amongst inter-patient and intra-patient acquisitions that could highly affect clinical interpretation. The methodology behind synthetic correlated diffusion imaging, which can be summarized as follows. First, multiple native DWI acquisitions are performed using a set of b-values . Second, the native signal acquisitions S are passed into a signal synthesizer to compute synthetic signal acquisitions . Third, the native and synthetic signal acquisitions are mixed together in a calibrated manner to obtain the local correlation of signal attenuation across the acquired signals, which produces a final signal (C) that characterizes the tissue being imaged with greater consistency in dynamic range across machines and protocols. The methodology behind CDI is summarized in Fig. 4. First, multiple DWI signal acquisitions are conducted using a set of different configurations of gradient pulse strengths and timings. By varying these configurations between signal acquisitions, each acquisition is sensitized to a different degree of Brownian motion, allowing the multiple signal acquisitions to provide a more complete picture of the tissue characteristics within a local volume by quantifying the distribution of water molecules with respect to their degree of Brownian motion within tissue. The different configurations of gradient pulse strengths and timings used in CDI can be represented by a set of so-called b-values, denoted . Each b-value may be expressed aswhere denotes the proton gyromagnetic ratio, represents the gradient pulse strength, represents the gradient pulse duration, and represents the time between gradient pulses[35].
Figure 4

The methodology behind synthetic correlated diffusion imaging, which can be summarized as follows. First, multiple native DWI acquisitions are performed using a set of b-values . Second, the native signal acquisitions S are passed into a signal synthesizer to compute synthetic signal acquisitions . Third, the native and synthetic signal acquisitions are mixed together in a calibrated manner to obtain the local correlation of signal attenuation across the acquired signals, which produces a final signal (C) that characterizes the tissue being imaged with greater consistency in dynamic range across machines and protocols.

Second, the multiple acquired signals are then passed into a signal synthesizer to synthesize synthetic signal acquisitions at desired configurations of gradient pulse strengths and timings not captured via native signal acquisitions. Third, the native and synthetic signal acquisitions are mixed together in a calibrated manner to obtain the final quantitative signal characterizing the joint correlation across the acquired signals within a local volume V. The idea behind this calibrated signal mixing procedure in CDI stems from our hypothesis that the distribution of water molecules with different degrees of Brownian motion within tissue in a local volume with PCa would differ significantly from that with non-cancerous tissue. For example, healthy PZ regions are largely comprised of glandular tissue, resulting in tighter distributions characterized by high relative SI at gradient pulse configurations with lower b-values and low relative SI at gradient pulse configurations with higher b-values used in CDI. More importantly, BPH, AFMS, and CZ are all non-cancerous and are largely comprised of non-glandular tissue, resulting in distributions characterized by low relative SI across all gradient pulse strengths and timings used in CDI. On the other hand, PCa regions are characterized by a more heterogeneous mixture of tissue with various degrees of relatively high cellular densities, resulting in a wider spread in the distribution of water molecules with varying degrees of Brownian motion within a local volume, including slow moving water molecules due to various degrees of true restricted diffusion, and thus high relative SI across all gradient pulse strengths and timings used in CDI. In the case of DWI, ADC hypointensity is exhibited by BPH, AFMS, CZ, and PCa, resulting in significant ADC overlaps between them (particularly depending on the choice of DWI sequence) and thus increased risk of false positives[30]. By taking advantage of these distribution differences between PCa and non-cancerous tissue in the signal mixing process in the form of joint correlation in a calibrated fashion, CDI can achieve improved signal contrast between PCa and non-cancerous tissue and facilitate for more effective PCa screening and diagnosis, as well as greater consistency in SI dynamic range across machines and protocols to reduce inter-patient and intra-patient variability in clinical interpretation. As mentioned earlier, we extend upon the signal mixing process in CDI[19] in two key ways to form CDI. First, we introduce a calibrated signal mixing function for characterizing the contribution-adjusted local signal correlation across the multiple signal acquisitions, which is parameterized by a set of b-values and is defined aswhere represents spatial location, S represents a signal acquisition, f presents the conditional joint probability density function, represents a local volume around , represents coefficients for controlling the contribution of the different gradient pulse strengths and timings, and Z represents a calibration factor. The calibration factor allow the signal mixing function to compensate for inherent variations due to the scanner machine and imaging protocol used during acquisition which can lead to differences in CDI SI appearance across patients or even for the same patient at different acquisitions. For this study, was set at (at intervals), V was defined as a 6 mm  6 mm  3 mm volume centered at , and the definition of will be discussed in a later section. The probability density function f was defined as an uncorrelated Gaussian distribution with mean and covariance matrix , and the calibration factor Z is computed as the median CDI SI within the prostate gland. These definitions yield the specific form of Equ. (2) used in this study: Second, we introduce the hybrid use of both native and synthetic signal acquisitions in the signal mixing process, thus leading to the notion of CDI. The use of synthetic signal acquisitions alongside native signal acquisitions enables us to reduce the acquisition time required to capture signals at gradient pulse configurations with higher b-values, as well as overcome SNR limitations with acquiring signals at gradient pulse configurations with higher b-values due to factors such as longer echo times and eddy current-induced distortions. Furthermore, it enables the leveraging of existing clinical imaging protocols and pulse sequences that are routine in mpMRI imaging sessions. More specifically, a synthetic signal acquisition at gradient pulse configuration w ith a particular b-value can be synthesized at the signal synthesizer aswhere is a reference signal acquisition at and is the least-squares ADC estimate. is given by Equ. (5), where and are the average b-value and average log-intensity of the acquired native signals, respectively: In this study, native signal acquisitions at were leveraged to synthesize the aforementioned synthetic signal acquisitions at (at intervals). The synthesized signal acquisitions were then used alongside the native signal acquisition at in the signal mixing process for CDI.

CDI coefficient optimization

As described in Equ. (2), the contribution of different gradient pulse strengths and timings to the CDI signal produced by the signal mixer can be controlled via coefficients . In this study, we will study the efficacy of CDI in both a baseline form (i.e., for all gradient pulse strengths and timings) as well as in a form that is tuned specifically to optimize delineation. More specifically, we tune the coefficients for the different gradient pulse strengths and timings using a Nelder-Mead simplex optimization strategy, with the objective function being the area under the ROC curve. This coefficient optimization will yield a tuned form of CDI, which we denote CDI, that accounts for the importance of the different gradient pulse strengths and timings to delineation performance.

Visualization of CDI

To map CDI SI in a form that is more natural for clinical interpretation, the CDI SI is transformed to the logarithmic space for clinical visualization purposes. Given that CDI is computed as a product of exponential signal acquisitions, CDI SI is more naturally interpreted in a logarithmic space. Furthermore, the transformed CDI SI is visualized as a heatmap overlay on T2w images to provide additional anatomical context with respect to the prostate gland. All image visualizations of CDI SI in this study are shown with the aforementioned transforms. Finally, DWI-derived ADC and DCE-derived are visualized as heatmap overlays on T2w images for comparison purposes in this study.

Statistical analysis

Two different analysis methods were utilized in this study to investigate the relationship between CDI SI and the presence of PCa, as well as the performance of CDI for delineating between csPCa tissue, insPCa tissue, and healthy tissue. In the first analysis method, we study the relationship between CDI SI and the presence of PCa by performing histogram analysis to study the distribution of CDI SI for healthy tissue, csPCa tissue, and insPCa tissue. In the second analysis method, a receiver operating characteristic (ROC) curve analysis was performed using CDI to quantitatively assess the ability to delineate between healthy tissue, csPCa tissue, and insPCa tissue. Consistent with the contemporary concept of significant versus insignificant prostate cancer (csPCa vs. insPCa)[21], csPCa tissue is defined as tissue with a Gleason score greater than or equal to 7 (Gleason Grade Groups 2–5 according to the International Society of Urological Pathology) while insPCa tissue is defined as tissue with a Gleason score less than 7 (Gleason Grade Group 1). The ROC curves were estimated empirically, and for illustrative purposes ROC curves obtained from the pooled data of all patient cases were plotted. To provide a quantitative assessment of diagnostic accuracy, the area under the ROC curve was obtained as a single metric of delineation performance. For comparison purposes, histogram analysis and ROC curve analysis were also performed using T2w, DWI-derived ADC map values, and DCE-derived map values. To assess the statistical significance of differences in AUC values between different modalities, we adopt the critical ratio formulation of Hanley and McNeil[22]. Specifically, for each pair of modalities, the critical ratio z is defined as:where and denote to the AUC and estimated standard error (SE) of modality 1, and denote the AUC and estimated SE of modality 2, and r denotes the estimated correlation between and . The estimated SE for each modality is defined as:where and denote the number of true positive and true negative examples, respectively. To estimate the correlation coefficient r, the Pearson product-moment correlation is first used to estimate correlation between the two modalities for positive examples () and negative examples (). The average of and and the average of and are then used to linearly interpolate the standard table presented by Hanley and McNeil[22] to estimate r. Notably, differences in image resolution prevent one-to-one comparison of voxels when estimating the Pearson product-moment correlation, and as such the median values for csPCa, insPCa, and healthy tissue are used (computed per-patient).

Software

Data processing, statistical analysis, and visualization was performed using the Python programming language (version 3.7.5) with the following libraries: OpenCV (version 4.2.0.34)[36], pydicom (version 2.1.2)[37], NiBabel (version 3.0.2)[38], SciPy (version 1.4.1)[39], scikit-learn (version 0.22.2.post1)[40], NumPy (version 1.18.2)[41], SimpleITK (version 2.0.2)[42], and Matplotlib (version 3.2.1)[43].

Ethics

This study has received ethics clearance from the University of Waterloo (30632), and was carried out in accordance with relevant guidelines and regulations. Informed consent was obtained from all subjects and/or their legal guardian(s). Supplementary Information.
  35 in total

Review 1.  Screening for prostate cancer: a review of the evidence for the U.S. Preventive Services Task Force.

Authors:  Roger Chou; Jennifer M Croswell; Tracy Dana; Christina Bougatsos; Ian Blazina; Rongwei Fu; Ken Gleitsmann; Helen C Koenig; Clarence Lam; Ashley Maltz; J Bruin Rugge; Kenneth Lin
Journal:  Ann Intern Med       Date:  2011-10-07       Impact factor: 25.391

Review 2.  The contemporary concept of significant versus insignificant prostate cancer.

Authors:  Guillaume Ploussard; Jonathan I Epstein; Rodolfo Montironi; Peter R Carroll; Manfred Wirth; Marc-Oliver Grimm; Anders S Bjartell; Francesco Montorsi; Stephen J Freedland; Andreas Erbersdobler; Theodorus H van der Kwast
Journal:  Eur Urol       Date:  2011-05-17       Impact factor: 20.096

3.  Is apparent diffusion coefficient associated with clinical risk scores for prostate cancers that are visible on 3-T MR images?

Authors:  Baris Turkbey; Vijay P Shah; Yuxi Pang; Marcelino Bernardo; Sheng Xu; Jochen Kruecker; Julia Locklin; Angelo A Baccala; Ardeshir R Rastinehad; Maria J Merino; Joanna H Shih; Bradford J Wood; Peter A Pinto; Peter L Choyke
Journal:  Radiology       Date:  2010-12-21       Impact factor: 11.105

4.  Comparison of MRI with CT for the radiotherapy planning of prostate cancer: a feasibility study.

Authors:  V S Khoo; A R Padhani; S F Tanner; D J Finnigan; M O Leach; D P Dearnaley
Journal:  Br J Radiol       Date:  1999-06       Impact factor: 3.039

Review 5.  Functional MR imaging of prostate cancer.

Authors:  Young Jun Choi; Jeong Kon Kim; Namkug Kim; Kyoung Won Kim; Eugene K Choi; Kyoung-Sik Cho
Journal:  Radiographics       Date:  2007 Jan-Feb       Impact factor: 5.333

6.  Computer-aided detection of prostate cancer in MRI.

Authors:  Geert Litjens; Oscar Debats; Jelle Barentsz; Nico Karssemeijer; Henkjan Huisman
Journal:  IEEE Trans Med Imaging       Date:  2014-05       Impact factor: 10.048

7.  Combined T2-weighted and diffusion-weighted MRI for localization of prostate cancer.

Authors:  Masoom A Haider; Theodorus H van der Kwast; Jeff Tanguay; Andrew J Evans; Ali-Tahir Hashmi; Gina Lockwood; John Trachtenberg
Journal:  AJR Am J Roentgenol       Date:  2007-08       Impact factor: 3.959

8.  Prostate MRI based on PI-RADS version 2: how we review and report.

Authors:  Philipp Steiger; Harriet C Thoeny
Journal:  Cancer Imaging       Date:  2016-04-11       Impact factor: 3.909

9.  Diagnostic performance of diffusion-weighted imaging for prostate cancer: Peripheral zone versus transition zone.

Authors:  Hakmin Lee; Sung Il Hwang; Hak Jong Lee; Seok-Soo Byun; Sang Eun Lee; Sung Kyu Hong
Journal:  PLoS One       Date:  2018-06-22       Impact factor: 3.240

Review 10.  SciPy 1.0: fundamental algorithms for scientific computing in Python.

Authors:  Pauli Virtanen; Ralf Gommers; Travis E Oliphant; Matt Haberland; Tyler Reddy; David Cournapeau; Evgeni Burovski; Pearu Peterson; Warren Weckesser; Jonathan Bright; Stéfan J van der Walt; Matthew Brett; Joshua Wilson; K Jarrod Millman; Nikolay Mayorov; Andrew R J Nelson; Eric Jones; Robert Kern; Eric Larson; C J Carey; İlhan Polat; Yu Feng; Eric W Moore; Jake VanderPlas; Denis Laxalde; Josef Perktold; Robert Cimrman; Ian Henriksen; E A Quintero; Charles R Harris; Anne M Archibald; Antônio H Ribeiro; Fabian Pedregosa; Paul van Mulbregt
Journal:  Nat Methods       Date:  2020-02-03       Impact factor: 28.547

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.