Literature DB >> 35230508

Perfusion analysis of benign parotid gland tumors by contrast-enhanced ultrasonography (CEUS).

Hans J Welkoborsky1, Maria Albers2, Julian Küstermeyer2.   

Abstract

BACKGROUND: Diagnosis of parotid gland tumors is sometimes challenging due to their diversity and pleomorphic histological appearance. B-scan sonography along with color-coded duplex sonography is the gold standard in the diagnostic workup of these lesions, whereas histopathology is to date the gold standard for the final diagnosis. To date no single imaging technique provides the chance for an art-diagnosis with highly diagnostic accuracy. Contrast enhanced ultrasonography (CEUS) on the other hand provides information of the perfusion down to the capillary level. Currently there are only a few papers published with systematical examination of the perfusion in benign parotid gland tumors and its diagnostic significance. PATIENTS AND METHODS: One hundred patients with a parotid gland tumor were examined. The examinations included conventional B-scan sonography, color-coded duplexsonography along with contrast enhanced ultrasonography (CEUS). B-scan sonographic parameters, i.e. echogenicity, shape, size, demarcation, and borders of a lesion along with vascularization estimated by color-coded-duplexsonography were analyzed. Analysis of quantitative CEUS parameters was performed using 8 regions of interest (ROI), which were standardized located throughout the entire tumors. The perfusion parameters were analyzed for particular tumor entities. Qualitative CEUS analysis with estimating the perfusion pattern was additionally performed.
RESULTS: Histological examination revealed benign tumors in 92 cases, with pleomorphic adenomas and Warthin´s tumors were the most frequent entities. Malignant conditions were found in 8 cases. CEUS revealed a centripetal perfusion pattern in malignant tumors significantly more frequently than in benign tumors. CEUS showed a significant heterogenic perfusion in all tumors, with a higher perfusion in the medial parts of the tumors and in some cases also in the center. Perfusion patterns of PA and WT were different. WT displayed centrifugal, centripetal, and central diffuse perfusion more often than PA, whereas in PA perfusion often was limited to the capsule or periphery. Oncocytoma had the highest perfusion values. Intraglandular cysts showed no intralesional perfusion.
CONCLUSIONS: CEUS analysis in different parts of benign tumors revealed a significant heterogeneity in tumor perfusion. Some perfusion pattern could be identified which might be characteristic for particular lesions. Based on this, the diagnostic accuracy of CEUS in the differential diagnosis of parotid gland tumors can be increased. In particular, the perfusion analysis within the tumors using ROIs located standardized throughout the entire tumor provides additional information which are important for the art diagnosis and in differentiation of tumor entity.
© 2022. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

Entities:  

Keywords:  Benign parotid gland tumors; CEUS; Cystadenolymphoma; Monomorphic adenoma; Perfusion pattern; Pleomorphic adenoma; Ultrasonography

Mesh:

Substances:

Year:  2022        PMID: 35230508     DOI: 10.1007/s00405-022-07303-z

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  5 in total

1.  Multimodal Ultrasonographic Pathway of Parotid Gland Lesions.

Authors:  Naglaa Mansour; Murat Bas; Konrad Friedrich Stock; Ulrich Strassen; Benedikt Hofauer; Andreas Knopf
Journal:  Ultraschall Med       Date:  2015-08-14       Impact factor: 6.548

Review 2.  Ultrasonography techniques in the preoperative diagnosis of parotid gland tumors - an updated review of the literature.

Authors:  Sebastian Stoia; Grigore Băciuț; Manuela Lenghel; Radu Badea; Mihaela Băciuț; Simion Bran; Dinu Cristian
Journal:  Med Ultrason       Date:  2020-10-14       Impact factor: 1.611

3.  Characteristics of pleomorphic adenomas, adenolymphomas, and malignant tumors of the salivary glands on color doppler ultrasonography and contrast enhanced ultrasonography.

Authors:  L-P Jiang
Journal:  Eur Rev Med Pharmacol Sci       Date:  2020-11       Impact factor: 3.507

4.  [Perfusion analysis in parotid gland tumors using contrast-enhanced ultrasound (CEUS)].

Authors:  Maria Agnes Albers; Julian Küstermeyer; Hans-Jürgen Welkoborsky
Journal:  HNO       Date:  2021-06-23       Impact factor: 1.284

5.  Multiparametric ultrasound evaluation of parotid gland tumors: B-mode and color Doppler in comparison and in combination with contrast-enhanced ultrasound and elastography. A case report of a misleading diagnosis.

Authors:  Antonello Rubini; Olga Guiban; Vito Cantisani; Ferdinando D'Ambrosio
Journal:  J Ultrasound       Date:  2020-05-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.