Baizhen Chen1,2, Shaoyang Cui3, Mingzhu Xu4, Zhijie Zhang5, Chunlong Liu1.
Abstract
Purpose: This study investigated the effects of isometric plantar-flexion against different resistances on the thoracolumbar fascia (TLF), erector spinae (ES), and gastrocnemius stiffness by shear wave elastography (SWE). The purpose was to explore the interaction between the lower limb muscle and lumbar tissue in the myofascial tensegrity network.Entities:
Keywords: gastrocnemius; isometric plantar-flexion; myofascial continuity; shear wave elastography; tensegrity network; thoracolumbar fascia
Year: 2022 PMID: 35223818 PMCID: PMC8874132 DOI: 10.3389/fbioe.2021.810250
Source DB: PubMed Journal: Front Bioeng Biotechnol ISSN: 2296-4185
FIGURE 1Setting out plan of the ultrasound transducer: (A) thoracolumbar fascia and erector spinae and (B) medial gastrocnemius and lateral gastrocnemius.
FIGURE 2The posture and equipment used for measurement: (A) ergometer, (B) wooden block, and (C) monitor.
FIGURE 3Stiffness variation of each tissue under different resistance conditions. ***, significant intergroup difference (p < 0.001); NS, non-significant intergroup difference (p > 0.05).
Tissue stiffness phase percentage change (mean ± SD, %).
| Measurement position | 0–20% MVIC | 20–40% MVIC | 40–60% MVIC | ||
|---|---|---|---|---|---|
| TLF | L3 | Left | 73.49 ± 21.78 | 88.00 ± 4.55 | 39.43 ± 4.98 |
| Right | 44.03 ± 24.83 | 60.75 ± 15.11 | 41.54 ± 9.97 | ||
| L4 | Left | 71.41 ± 19.96 | 66.74 ± 5.97 | 35.12 ± 3.92 | |
| Right | 50.67 ± 16.06 | 51.31 ± 8.35 | 19.18 ± 6.96 | ||
| ES | L3 | Left | 160.01 ± 55.18 | 114.88 ± 17.28 | 69.78 ± 6.01 |
| Right | 130.71 ± 52.98 | 128.65 ± 26.67 | 45.91 ± 5.89 | ||
| L4 | Left | 204.58 ± 50.99 | 81.00 ± 10.12 | 46.33 ± 7.51 | |
| Right | 174.64 ± 49.36 | 84.97 ± 17.24 | 36.47 ± 16.77 | ||
| MG | — | 175.83 ± 52.76 | 46.87 ± 9.57 | 22.23 ± 6.26 | |
| LG | — | 31.34 ± 18.73 | 188.90 ± 39.92 | 12.63 ± 13.14 | |
SD, standard deviation (kPa); TLF, thoracolumbar fascia; ES, erector spinae; L3, third lumbar vertebra levels; L4, fourth lumbar vertebra levels; MG, medial gastrocnemius; LG, lateral gastrocnemius.
The correlation between the stiffness percentage changes of each tissue (mean ± SD, %).
| Measurement parts | 0–20% MVIC | 0–40% MVIC | 0–60% MVIC | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Percentage change |
|
| Percentage change |
|
| Percentage change |
|
| |||
| TLF | L3 | Left | 73.49 ± 21.78 | 0.936 | 0.000 | 226.69 ± 45.70 | 0.913 | 0.000 | 353.69 ± 51.29 | 0.847 | 0.000 |
| Right | 44.03 ± 24.83 | 0.943 | 0.000 | 130.93 ± 40.91 | 0.898 | 0.000 | 225.36 ± 64.92 | 0.850 | 0.000 | ||
| L4 | Left | 71.41 ± 19.96 | 0.912 | 0.000 | 185.32 ± 30.53 | 0.927 | 0.000 | 285.75 ± 44.72 | 0.883 | 0.000 | |
| Right | 50.67 ± 16.06 | 0.839 | 0.000 | 128.31 ± 29.56 | 0.877 | 0.000 | 170.40 ± 23.20 | 0.768 | 0.000 | ||
| ES | L3 | Left | 160.01 ± 55.18 | 0.910 | 0.000 | 450.89 ± 82.36 | 0.907 | 0.000 | 831.82 ± 116.02 | 0.858 | 0.000 |
| Right | 130.71 ± 52.98 | 0.926 | 0.000 | 418.66 ± 94.99 | 0.889 | 0.000 | 656.62 ± 138.90 | 0.868 | 0.000 | ||
| L4 | Left | 204.58 ± 50.99 | 0.930 | 0.000 | 446.75 ± 65.19 | 0.925 | 0.000 | 702.95 ± 125.01 | 0.887 | 0.000 | |
| Right | 174.64 ± 49.36 | 0.884 | 0.000 | 401.15 ± 54.98 | 0.743 | 0.000 | 576.86 ± 44.97 | 0.809 | 0.000 | ||
| MG | — | 175.83 ± 52.76 | 1 | — | 302.91 ± 66.83 | 1 | — | 392.95 ± 91.29 | 1 | — | |
| LG | — | 31.34 ± 18.73 | 0.800 | 0.000 | 276.53 ± 54.80 | 0.703 | 0.001 | 320.53 ± 57.57 | 0.588 | 0.006 | |
SD, standard deviation (kPa); TLF, thoracolumbar fascia; ES, erector spinae; L3, third lumbar vertebra levels; L4, fourth lumbar vertebra levels; MG, medial gastrocnemius; LG, lateral gastrocnemius.