Nephrologist-performed portal vein Doppler to monitor response to diuretic therapy.

Abhilash Koratala1.   

Abstract

Conventional parameters for assessment of fluid status suffer from several limitations. IVC maybe chronically dilated in patients with pulmonary hypertension. Portal vein Doppler offers an additional data point to assess the severity of venous congestion as well as monitor the efficacy of decongestive therapy.
© 2022 The Authors. Clinical Case Reports published by John Wiley & Sons Ltd.

Entities:  

Keywords:  Doppler; nephrology; point‐of‐care ultrasonography; point‐of‐care ultrasound; venous Doppler

Year:  2022        PMID: 35223002      PMCID: PMC8843834          DOI: 10.1002/ccr3.5357

Source DB:  PubMed          Journal:  Clin Case Rep        ISSN: 2050-0904


DOES THE PORTAL VEIN DOPPLER WAVEFORM CHANGE IN RESPONSE TO DECONGESTIVE THERAPY IN HEART FAILURE PATIENTS?

There has been a growing interest in the utility of point‐of‐care ultrasonography (POCUS) for the assessment of fluid status in patients with heart failure (HF). , A 78‐year‐old woman with a history of HF with reduced ejection fraction (~20%) and pulmonary hypertension presented with altered mental status. Laboratories were significant for acute kidney injury (AKI) with a serum creatinine of 2.2 mg/dl (baseline ~1.1) and leukocyturia. AKI was presumed to be secondary to volume depletion as her oral diuretic regimen was recently intensified. Moreover, there was no significant increase in weight compared with last documented value nor obvious jugular venous distension. NT‐pro‐BNP was 8118 pg/ml (last available was 10,537). 1 liter of isotonic fluid was administered, and diuretics were held. Her mental status improved with the treatment of urinary infection, but AKI was persistent, for which nephrology was consulted. POCUS‐assisted physical examination with a handheld ultrasound device (KosmosTM, EchoNous, Inc.) demonstrated severely impaired left ventricular systolic function and a plethoric inferior vena cava (IVC) (Video S1). Portal vein Doppler waveform was pulsatile with intermittent flow reversal consistent with severe venous congestion. Based on these findings, intravenous diuretic therapy was instituted. Serum creatinine improved to 1 mg/dl at discharge. While IVC continued to be dilated (Figure 1), portal vein Doppler waveform showed consistent improvement during decongestive therapy (Figure 2). This Doppler parameter is a valuable addition to the tool kit of clinicians managing patients with HF and cardiorenal syndrome. In addition, combined assessment of hepatic, portal, and renal parenchymal venous Doppler (VExUS scan) has shown to predict AKI in selected patients.
FIGURE 1

Dilated inferior vena cava in transverse axis at the time of nephrology consult (evaluation 1) and final follow‐up (evaluation 3). Note that the anteroposterior diameter has minimally changed

FIGURE 2

Portal vein Doppler at the time of nephrology consult (evaluation 1), 2 days after starting diuretic therapy (evaluation 2), and final follow‐up 2 days later (evaluation 3). Note the improvement in pulsatility (normal is less than 30%)

Dilated inferior vena cava in transverse axis at the time of nephrology consult (evaluation 1) and final follow‐up (evaluation 3). Note that the anteroposterior diameter has minimally changed Portal vein Doppler at the time of nephrology consult (evaluation 1), 2 days after starting diuretic therapy (evaluation 2), and final follow‐up 2 days later (evaluation 3). Note the improvement in pulsatility (normal is less than 30%)

CONFLICT OF INTEREST

The author has declared that no conflict of interest exists.

AUTHOR CONTRIBUTIONS

AK performed sole author and attending nephrologist on the case, performed, and interpreted ultrasound scans.

CONSENT

Written informed consent was obtained from the patient to publish this report in accordance with the journal's patient consent policy. Video S1 Click here for additional data file.
  3 in total

1.  Dynamic Changes in Portal Vein Flow during Decongestion in Patients with Heart Failure and Cardio-Renal Syndrome: A POCUS Case Series.

Authors:  Eduardo R Argaiz; Philippe Rola; Gerardo Gamba
Journal:  Cardiorenal Med       Date:  2021-01-21       Impact factor: 2.041

Review 2.  Point of Care Ultrasonography for Objective Assessment of Heart Failure: Integration of Cardiac, Vascular, and Extravascular Determinants of Volume Status.

Authors:  Abhilash Koratala; Amir Kazory
Journal:  Cardiorenal Med       Date:  2021-01-21       Impact factor: 2.041

3.  Quantifying systemic congestion with Point-Of-Care ultrasound: development of the venous excess ultrasound grading system.

Authors:  William Beaubien-Souligny; Philippe Rola; Korbin Haycock; Josée Bouchard; Yoan Lamarche; Rory Spiegel; André Y Denault
Journal:  Ultrasound J       Date:  2020-04-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.