Literature DB >> 35211830

Incidence and predictors of transcatheter aortic valve replacement device emboligenic matter detected by transesophageal echocardiography.

Masaki Yashige1, Kan Zen2, Shunsuke Nakamura1, Tomotaka Fujimoto1, Kazuaki Takamatsu1, Nobuyasu Ito1, Yoshito Kadoya1, Michiyo Yamano1, Tetsuhiro Yamano1, Takeshi Nakamura1, Hitoshi Yaku3, Satoaki Matoba1.   

Abstract

During transfemoral (TF) or transcatheter aortic valve replacement (TAVR), transesophageal echocardiography (TEE) sometimes reveals an unexpected mobile membranous mass on the catheter tip within the proximal part of the descending thoracic aorta. Such mobile masses may cause critical embolic events if the TAVR device advances into the ascending aorta in the absence of preventive measures. This study aimed to investigate the incidence and predictors of emboligenic matter (EM) during TAVR, impact of EM on the procedure, and incidence of symptomatic ischemic stroke post procedure. Among 436 consecutive patients who underwent TF-TAVR, 407 were evaluated in this study. The primary end point was incidence of symptomatic ischemic stroke within 24 h post procedure while taking appropriate preventive measures. Incidence of EM, factors associated with EM, and the impact of EM on the procedure were also investigated. Among the 407 cases, 15 cases (3.7%) of EM were identified but no ischemic stroke occurred in the EM (+) group (0% vs. 2.04%, p = 1.00). In the EM (+) group, a self-expandable valve was used in all 15 cases (100% vs. 42.6%, p < 0.0001) while 14 cases used a CoreValve's InLine sheath system initially (93.3% vs. 27.3%, p < 0.0001). CoreValve's InLine sheath system usage was the only independent predictor of EM. The CoreValve's InLine delivery system was identified as a predictor of EM during TF-TAVR, but symptomatic ischemic stroke was avoided while taking appropriate embolization preventive measures.
© 2022. The Author(s), under exclusive licence to Springer Nature B.V.

Entities:  

Keywords:  Aortic stenosis; Embolization; Ischemic stroke; Transcatheter aortic valve replacement; Transesophageal echocardiography

Year:  2022        PMID: 35211830     DOI: 10.1007/s10554-022-02567-2

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  14 in total

1.  Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology.

Authors:  Roberto M Lang; Michelle Bierig; Richard B Devereux; Frank A Flachskampf; Elyse Foster; Patricia A Pellikka; Michael H Picard; Mary J Roman; James Seward; Jack S Shanewise; Scott D Solomon; Kirk T Spencer; Martin St John Sutton; William J Stewart
Journal:  J Am Soc Echocardiogr       Date:  2005-12       Impact factor: 5.251

2.  Computed Tomography Imaging in the Context of Transcatheter Aortic Valve Implantation (TAVI)/Transcatheter Aortic Valve Replacement (TAVR): An Expert Consensus Document of the Society of Cardiovascular Computed Tomography.

Authors:  Philipp Blanke; Jonathan R Weir-McCall; Stephan Achenbach; Victoria Delgado; Jörg Hausleiter; Hasan Jilaihawi; Mohamed Marwan; Bjarne L Nørgaard; Niccolo Piazza; Paul Schoenhagen; Jonathon A Leipsic
Journal:  JACC Cardiovasc Imaging       Date:  2019-01

3.  Conscious Sedation Versus General Anesthesia for Transcatheter Aortic Valve Replacement: Variation in Practice and Outcomes.

Authors:  Neel M Butala; Mabel Chung; Eric A Secemsky; Pratik Manandhar; Guillaume Marquis-Gravel; Andrzej S Kosinski; Sreekanth Vemulapalli; Robert W Yeh; David J Cohen
Journal:  JACC Cardiovasc Interv       Date:  2020-06-08       Impact factor: 11.195

4.  Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document.

Authors:  A Pieter Kappetein; Stuart J Head; Philippe Généreux; Nicolo Piazza; Nicolas M van Mieghem; Eugene H Blackstone; Thomas G Brott; David J Cohen; Donald E Cutlip; Gerrit-Anne van Es; Rebecca T Hahn; Ajay J Kirtane; Mitchell W Krucoff; Susheel Kodali; Michael J Mack; Roxana Mehran; Josep Rodés-Cabau; Pascal Vranckx; John G Webb; Stephan Windecker; Patrick W Serruys; Martin B Leon
Journal:  Eur Heart J       Date:  2012-10       Impact factor: 29.983

5.  Outcomes of transcatheter aortic valve replacement using a minimalist approach.

Authors:  Sergey Gurevich; Brett Oestreich; Rosemary F Kelly; Mackenzie Mbai; Stefan Bertog; Karen Ringsred; Annette Lawton; Brenda Thooft; Julie Wagner; Santiago Garcia
Journal:  Cardiovasc Revasc Med       Date:  2017-08-12

6.  Combining the CoreValve Evolut PRO and 14-French eSheath in transfemoral transcatheter aortic valve replacement.

Authors:  Masaki Yashige; Kan Zen; Yoshito Kadoya; Satoaki Matoba
Journal:  Cardiovasc Interv Ther       Date:  2020-04-20

7.  Exfoliated Endothelium Identified by Transesophageal Echocardiography During Transcatheter Aortic Valve Replacement.

Authors:  Yoshito Kadoya; Kan Zen; Michiyo Yamano; Tetsuhiro Yamano; Takeshi Nakamura; Hitoshi Yaku; Satoaki Matoba
Journal:  JACC Cardiovasc Interv       Date:  2020-02-22       Impact factor: 11.195

8.  Abdominal aorta tortuosity on computed tomography identifies patients at risk of complications during transfemoral transcatheter aortic valve replacement.

Authors:  Marine Kinnel; Laurent Faroux; Aurélien Villecourt; Sophie Tassan-Mangina; Virginie Heroguelle; Pierre Nazeyrollas; Anne Poncet; Vito Giovanni Ruggieri; Damien Metz
Journal:  Arch Cardiovasc Dis       Date:  2019-11-12       Impact factor: 2.340

9.  Comparison of transfemoral transcatheter aortic valve replacement performed in the catheterization laboratory (minimalist approach) versus hybrid operating room (standard approach): outcomes and cost analysis.

Authors:  Vasilis Babaliaros; Chandan Devireddy; Stamatios Lerakis; Robert Leonardi; Sebastian A Iturra; Kreton Mavromatis; Bradley G Leshnower; Robert A Guyton; Mihir Kanitkar; Patricia Keegan; Amy Simone; James P Stewart; Nima Ghasemzadeh; Peter Block; Vinod H Thourani
Journal:  JACC Cardiovasc Interv       Date:  2014-07-30       Impact factor: 11.195

10.  Association of atherosclerosis in the descending thoracic aorta with coronary artery disease on multi detector row computed tomography coronary angiography in patients with suspected coronary artery disease.

Authors:  Cornelis J Roos; Agnieszka J Witkowska; Michiel A de Graaf; Caroline E Veltman; Victoria Delgado; Greetje J de Grooth; J Wouter Jukema; Jeroen J Bax; Arthur J Scholte
Journal:  Int J Cardiovasc Imaging       Date:  2013-07-27       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.