| Literature DB >> 35208088 |
Olga A Goncharova1, Andrey Yu Luchkin1, Nina P Andreeva1, Vadim E Kasatkin1, Sergey S Vesely1, Nikolay N Andreev1, Yurii I Kuznetsov1.
Abstract
It has been shown by a set of corrosion, electrochemical and physical methods that a chamber corrosion inhibitor that consists of a mixture of octadecylamine (ODA) and benzotriazole (BTA) efficiently protects copper and brass from atmospheric corrosion and can be used for the temporary protection of metal items. The optimum temperatures of treatment with the ODA + BTA mixed inhibitor is 120 °C for brass and 100 °C for copper. One-hour treatment in ODA + BTA vapors at these temperatures results in the formation of nanosized adsorption films on the surface of these metals. These films stabilize the passive state and provide efficient temporary protection of metal items. The ODA + BTA inhibitor is superior to its components in terms of protective aftereffect. Our analysis of the mutual effect of BTA and ODA indicated that they show an antagonism of protective action on copper, but there is also a synergistic enhancement in the case of brass. Electrochemical impedance spectroscopy studies demonstrate that the inhibitors in question mainly act by using a blocking mechanism on copper and brass. Chamber treatment of the metals studied in vapors of the ODA + BTA mixture resulted in a noticeable hydrophobization of the copper surface and an insignificant effect on the brass surface. Chamber treatment of copper samples with artificially created polymodal roughness made it possible to obtain a superhydrophobic surface.Entities:
Keywords: atmospheric corrosion; brass; chamber corrosion inhibitors; copper; corrosion inhibitors; mixed corrosion inhibitors; mutual effect of components
Year: 2022 PMID: 35208088 PMCID: PMC8878769 DOI: 10.3390/ma15041541
Source DB: PubMed Journal: Materials (Basel) ISSN: 1996-1944 Impact factor: 3.623
Protective aftereffect (PAE) of adsorption films formed upon treatment of copper in CIN vapors at different t measured in a heat and moisture chamber. τCT = 60 min.
| Chamber | Time until Corrosion Damage Became Visible, h, after Chamber Treatment at the Following Temperatures: | |||
|---|---|---|---|---|
| 80 °C | 100 °C | 120 °C | 140 °C | |
| No CIN | 4.0 | 4.0 | - * | - * |
| BTA | 456 | 960 | - * | - * |
| ODA | 288 | 1080 | - * | - * |
| ODA + BTA | 3576 | 4800 | - * | - * |
* The samples changed color in the course of thermal and chamber treatment of the metal.
Protective aftereffect of adsorption films formed on copper in CIN vapors at 100 °C and at various τCT in the salt fog chamber.
| Chamber Inhibitor | Time until the Appearance of Corrosion Damage and Cycles after Chamber Treatment for Specified Period | ||
|---|---|---|---|
| 20 min | 40 min | 60 min | |
| No CIN | 2 | 2 | 2 |
| BTA | 15 | 15 | 14 |
| ODA | 14 | 17 | 24 |
| ODA + BTA | 15 | 15 | 15 |
Effect of copper chamber treatment on the thickness of surface films. TCT = 100 °C, and τCT = 60 min.
| Chamber Inhibitor | Thickness | |
|---|---|---|
| Oxide Film | Adsorbed CIN Film | |
| No CIN | 4.5 ± 0.5 | - |
| BTA | 1.5 ± 0.5 | 2.0 ± 0.5 |
| ODA | 1.5 ± 0.5 | 3.5 ± 0.5 |
| ODA + BTA | 1.5 ± 0.5 | 4.5 ± 0.5 |
Figure 1Polarization curves of copper in borate buffer (pH 7.36) +0.001 M NaCl. (1) No treatment with a CIN, (2) BTA, (3) ODA and (4) ODA + BTA.
Effect of copper CT on the characteristics of anodic potentiodynamic curves. TCT = 100 °C, and τCT = 60 min.
| Chamber Inhibitor | |||
|---|---|---|---|
| Without a CIN | 0.225 | 0.270 | 0.510 |
| BTA | 0.156 | - | 1.095 |
| ODA | 0.160 | - | 1.200 |
| ODA + BTA | −0.344 | 0.600 | 1.015 |
Figure 2Nyquist plots of copper samples after thermal treatment without a CIN (1) and after CT with the vapors of: BTA (2), ODA (3) and ODA + BTA (4).
Values of equivalent circuit elements based on the results of impedance spectroscopy, as calculated for different variants of copper CT. TCT = 100 °C, and τCT = 60 min.
| Chamber | Rs kΩ·cm2 | Rsl kΩ·cm2 | CPEsl | CPEsl | Rct kΩ·cm2 | CPEdl | CPEdl | Protection |
|---|---|---|---|---|---|---|---|---|
| No CIN | 0.4 | 386.85 | 9.78 × 10−7 | 0.87 | 215.57 | 9.35 × 10−6 | 1 | |
| BTA | 0.33 | 513.66 | 2.86 × 10−7 | 0.98 | 1895.94 | 2.64 × 10−7 | 0.79 | 89.44 |
| ODA | 0.48 | 1506.41 | 2.09 × 10−7 | 1 | 1113.54 | 9.37 × 10−7 | 1 | 90.29 |
| ODA + BTA | 0.41 | 2263.29 | 1.45 × 10−7 | 0.99 | 1655.61 | 3.19 × 10−7 | 1 | 93.51 |
Inhibition coefficients of chamber inhibitors by the blocking and activation mechanisms after different options of copper CT. TCT = 100 °C, and τCT = 60 min.
| Chamber Inhibitor | γsl | γct |
|---|---|---|
| BTA | 1.33 | 8.80 |
| ODA | 3.89 | 5.17 |
| ODA + BTA | 5.85 | 7.68 |
Effect of copper CT on the contact angles of wetting with distilled water. TCT = 100 °C, and τCT = 60 min.
| Chamber Inhibitor | Contact Angle, Degree |
|---|---|
| No CIN | 75 |
| BTA | 107 |
| ODA | 104 |
| ODA + BTA | 112 |
| ODA + BTA, polymodal surface | 160 |
Figure 3Copper samples after weathering tests for 25 months: chamber treatment with CIN vapors (a–c); without chamber treatment (d).
Protective aftereffect of adsorption films formed upon brass treatment in CIN vapors at various temperatures. Recurrent moisture condensation conditions. τCT = 60 min.
| Chamber Inhibitor | Time until the Appearance of Corrosion Damage, h, after Chamber Treatment at Temperature: | |||
|---|---|---|---|---|
| 80 °C | 100 °C | 120 °C | 140 °C | |
| No CIN | 2.0 | 2.0 | 2.0 | - * |
| BTA | 2.0 | 5.0 | 5.0 | - * |
| ODA | 2.0 | 2.0 | 2.0 | - * |
| ODA + BTA | 24 | 1416 | 2232 | - * |
* The samples changed color in the course of thermal and chamber treatment of the metal.
Protective aftereffect of adsorption films formed on brass in CIN vapors at 120 °C and at various τCT in the salt fog chamber.
| Chamber Inhibitor | Time until Corrosion Damage Appeared, Cycles, after Chamber Treatment for a Period of: | |||
|---|---|---|---|---|
| 15 min | 30 min | 60 min | 75 min | |
| No CIN | 1 | 1 | 1 | - * |
| BTA | 1 | 1 | 1 | - * |
| ODA | 1 | 1 | 1 | - * |
| ODA + BTA | 3 | 5 | 15 | - * |
* The samples changed color in the course of thermal treatment or chamber treatment.
Effect of brass chamber treatment on the surface film thickness. TCT = 120 °C, and τCT = 60 min.
| Chamber Inhibitor | Thickness | |
|---|---|---|
| Oxide Film | Adsorbed CIN Film | |
| No CIN | 3.25 ± 0.25 | - |
| BTA | 3 ± 0.5 | 19 ± 2 |
| ODA | 1 ± 0.5 | 36 ± 1 |
| ODA + BTA | 2 ± 0.5 | 40 ± 1 |
Figure 4Polarization curves on brass in borate buffer (pH 7.36) + 0.001 M NaCl. (1) Without CIN treatment, (2) BTA, (3) ODA and (4) ODA + BTA.
Effect of brass CT on the parameters of anodic potentiodynamic curves.
| Chamber Inhibitor | ||
|---|---|---|
| No CIN | 0.105 | 0.445 |
| BTA | 0.095 | 0.665 |
| ODA | 0.110 | 0.675 |
| ODA + BTA | 0.145 | 1.080 |
Figure 5Nyquist plots of brass samples after TT without a CIN (1) and after CT in the vapors of BTA (2), ODA (3) and ODA + BTA (4).
The values of equivalent circuit elements based on the results of impedance spectroscopy calculated for different variants of brass CT. TCT = 120 °C, and τCT = 60 min.
| Chamber | Rs KΩ·cm2 | Rsl KΩ·cm2 | CPEsl | CPEsl | Rct KΩ·cm2 | CPEdl | CPEdl | Protection Z, % |
|---|---|---|---|---|---|---|---|---|
| No CIN | 0.55 | 27.5 | 8.26 × 10−7 | 0.84 | 31.5 | 6.22 × 10−5 | 0.76 | |
| BTA | 0.47 | 227.4 | 3.82 × 10−7 | 1 | 1701 | 1.39 × 10−7 | 1 | 96.94 |
| ODA | 0.67 | 5255 | 1.47 × 10−8 | 0.98 | 11833 | 2.76 × 10−8 | 0.80 | 99.65 |
| ODA + BTA | 0.44 | 44257 | 3.61 × 10−8 | 0.97 | 27284 | 1.43 × 10−8 | 0.93 | 99.93 |
Protective effects of the CINs by the blocking and activation mechanisms after brass chamber treatment in different modes. TCT = 120 °C, and τCT = 60 min.
| Chamber Inhibitor | γsl | γct |
|---|---|---|
| BTA | 8.27 | 54 |
| ODA | 191 | 376 |
| ODA + BTA | 1609 | 866 |
Effect of brass CT on the contact angles of wetting with distilled water. TCT = 120 °C, and τCT = 60 min.
| Chamber Inhibitor | Contact Angle, Deg. |
|---|---|
| Without a CIN | 85 |
| BTA | 88 |
| ODA | 92 |
| ODA + BTA | 93 |
| ODA + BTA, polymodal roughness | 146 |
Figure 6Brass samples after weathering tests for 25 months: chamber treatment with CIN vapors (a–c); without chamber treatment (d).