Chiara Pelosi1, Iren Constantinescu2, Helena H Son2, Maria Rosaria Tinè1, Jayachandran N Kizhakkedathu2,3, Frederik R Wurm4. 1. Dipartimento di Chimica e Chimica Industriale, Università di Pisa, Via Moruzzi 13, 56120 Pisa, Italy. 2. Center for Blood Research, Life Sciences Centre, Department of Pathology and Laboratory Medicine, University of British Columbia, 2350 Health Sciences Mall, Vancouver, British Columbia V6T 1Z3, Canada. 3. School of Biomedical Engineering, University of British Columbia, 2350 Health Sciences Mall, Vancouver, British Columbia V6T 1Z3, Canada. 4. Sustainable Polymer Chemistry (SPC), Department of Molecules and Materials, MESA+ Institute for Nanotechnology, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands.
Abstract
Polyphosphoesters (PPEs) are a class of versatile degradable polymers. Despite the high potential of this class of polymers in biomedical applications, little is known about their blood interaction and compatibility. We evaluated the hemocompatibility of water-soluble PPEs (with different hydrophilicities and molar masses) and PPE-coated model nanocarriers. Overall, we identified high hemocompatibility of PPEs, comparable to poly(ethylene glycol) (PEG), currently used for many applications in nanomedicine. Hydrophilic PPEs caused no significant changes in blood coagulation, negligible platelet activation, the absence of red blood cells lysis, or aggregation. However, when a more hydrophobic copolymer was studied, some changes in the whole blood clot strength at the highest concentration were detected, but only concentrations above that are typically used for biomedical applications. Also, the PPE-coated model nanocarriers showed high hemocompatibility. These results contribute to defining hydrophilic PPEs as a promising platform for degradable and biocompatible materials in the biomedical field.
Polyphosphoesters (PPEs) are a class of versatile degradable polymers. Despite the high potential of this class of polymers in biomedical applications, little is known about their blood interaction and compatibility. We evaluated the hemocompatibility of water-soluble PPEs (with different hydrophilicities and molar masses) and PPE-coated model nanocarriers. Overall, we identified high hemocompatibility of PPEs, comparable to poly(ethylene glycol) (PEG), currently used for many applications in nanomedicine. Hydrophilic PPEs caused no significant changes in blood coagulation, negligible platelet activation, the absence of red blood cells lysis, or aggregation. However, when a more hydrophobic copolymer was studied, some changes in the whole blood clot strength at the highest concentration were detected, but only concentrations above that are typically used for biomedical applications. Also, the PPE-coated model nanocarriers showed high hemocompatibility. These results contribute to defining hydrophilic PPEs as a promising platform for degradable and biocompatible materials in the biomedical field.
Polyphosphoesters
(PPEs) belong to the few polymer classes that
enable the synthesis of well-defined and degradable water-soluble
polymers.[1,2] The presence of pentavalent phosphorous
in the main chain allows for tuning the polymer properties (e.g.,
hydrophilicity, crystallinity, degradability, thermal stability, and
so forth) by varying the lateral group, providing the polymers with
high versatility. To date, several studies have reported the hydrolytic
and enzymatic degradation of PPEs in vitro,[3,4] and
PPE-containing (co)polymers were reported as noncytotoxic against
different cell lines even at high concentrations.[1] In addition, hydrophilic PPE-coated nanocarriers exhibit
a so-called “stealth effect,” and their cellular uptake
can be controlled depending on the polymer hydrophilicity.[5] Based on such results, PPEs have been proposed
for different biomedical applications, for example, protein–polymer
conjugates,[6−8] nanocarriers loaded with drugs,[9] antimicrobial agents,[10] gene
vectors,[11] or hydrogels for tissue engineering.[12] In many applications, PPEs are proposed as biodegradable
alternatives to poly(ethylene glycol) (PEG),[1,13,14] which is nowadays the most used water-soluble
polymer in nanomedicine to prolong the drug lifetime and efficiency.[15] In this context, the evaluation of PPE blood
compatibility is an important step to translate these in vitro results
to in vivo applications. However, there is limited information available
on the blood compatibility of this class of polymers. In a study,
Murgia and co-workers evaluated the hemolysis and the complement system
activation by cubosomes, that is, lyotropic nanoparticles with a cubic
internal nanostructure that were self-assembled from poly(propylene
oxide)-block-poly(methyl ethylene phosphate). Lower
cytotoxicity compared to the commonly used Pluronic F127 analogues
was detected.[16] A systematic blood compatibility
study of different PPEs has not been reported to date. Here, we report
the hemocompatibility of a set of PPEs with various molar masses and
different hydrophilicities, as well as PPE-coated model nanocarriers.
The results were compared to those of PEG, aiming at detecting any
difference in the hemocompatibility in view of future medical applications.
Experimental Section
Polymers
Synthesis and Features (Samples #1–4)
Polyphosphoesters
(PPE) synthesis was performed via ring-opening
polymerization, as described previously.[7,17] After the
synthesis, the polymers were dialyzed for 24 h in clinical water (sterile
and endotoxin-free). The endotoxin level was tested by the Limulus
amebocyte lysate assay (kit from Thermofisher), and only the samples
with an endotoxin level below 0.5 U/mL were taken into consideration
for further studies. For the determination of the polymer molecular
weight, gel permeation chromatography (GPC) was performed in N,N′-dimethylformamide (DMF; containing 0.25 g/L
of lithium bromide as an additive) using an Agilent 1100 Series as
the integrated instrument, including a PSS GRAM columns (1000/1000/
100 g), a UV detector (280 nm), and an RI (refractive index) detector
at a flow rate of 1 mL/min at 60 °C. Calibration was carried
out using PS standards provided by the Polymer Standards Service. 1H and 31P {H}-NMR spectra were acquired at 298.3
K with a Bruker AVANCE III 300 MHz spectrometer. The spectra were
calibrated against the solvent signal and analyzed using MestReNova
9.0.0 from Mestrelab Research S.L. The PPEs’ features and a
representative 1H NMR spectrum are reported in the Supporting
Information, Section 1.
Preparation of PPEylated Polystyrene Model
Nanocarriers (Sample #6)
Polystyrene nanoparticles (PS-NPs)
BODIPY-labeled, amino-functionalized, CTMA-Cl stabilized were synthesized
and characterized following the procedure, and the methodologies have
been described in a previous study.[5] (Dh (DLS): 118 nm; −NH2 groups
per particle: 20,000; solid content: 1.0%.). The polymer poly(ethyl
ethylene phosphonate) ω-functionalized with 4-(maleinimido)
phenyl isocyanate (PEtEP-MAL) was synthesized and characterized as
specified previously.[5] (Yield: 98%; Mn (NMR): 8400 g/mol (59 repeated units); 72.5%
of functionalization; Đ = 1.4). Nanoparticle
functionalization was performed as described: 72 μL of pyridine
were added to 3 mL of PS-NP dispersion (1% wt, 3.3 × 1013 particles, 1.2 × 10–6 mol NH2 groups)
to reach pH 8.3. The dispersion was stirred at 500 rpm for 20 min
at room temperature. Then, 2.5 eq. of PEtEP-MAL (with respect to the
−NH2 groups, 2.9 × 10–3 mmol)
was dissolved in 1 mL of sterile Millipore water and added dropwise
to the dispersion. The reaction was stirred for 24 h at room temperature
and 500 rpm to ensure full conversion. The dispersion was purified
by repeated centrifugation (3 × 1 h, 30,000 g). Each time, the
supernatant was removed, and the pellet was redispersed in sterile
Millipore water. After the last centrifugation, the dispersion was
adjusted to 1 wt. % with sterile Millipore water.Characteristics
of PPE-functionalized PS-NPs, sample 6: Dh (DLS): 122 nm; ξ-potential: −30.1 ± 6.7 mV; solid
content: 1.0 wt. %; number of polymers attached to each particle:
ca. 4000 (calculated by 1H NMR spectroscopy, as previously
described[5]). Pictures of sample 6 observed
by optical microscopy are reported in the Supporting Information, Section 1.
Blood
Sample Preparation
Blood was
collected from healthy consenting donors in a 3.2% sodium-citrated
vacutainer tube at the Centre for Blood Research, University of British
Columbia, Canada. For serum preparation, whole blood was collected
in a nonanticoagulated vacutainer tube. Platelet-rich plasma (PRP)
was prepared by centrifuging citrated whole blood samples at 150×g for 15 min in an Allegra X-22R centrifuge (Beckman Coulter,
Canada). Platelet-poor plasma (PPP) was prepared by centrifuging citrated
whole blood samples at 2000×g for 20 min. Serum
was prepared by centrifuging nonanticoagulated whole blood samples
at 2000×g for 20 min after resting 30 min at
room temperature to clot. The PPE samples were dissolved in isotonic
saline 0.9% solution. Both the PPE samples and all the reagents were
preincubated at 37 °C for 20 min before mixing. PPE stock solutions
at 1, 5, and 10 mg/mL were prepared in 0.9% isotonic saline solution.
The PPE samples were mixed in a 1/10 ratio with plasma or whole blood
to achieve final polymer concentrations of 0.1, 0.5, and 1 mg/mL.
Platelet Activation by Flow Cytometry
Fresh
blood from three different donors was collected, and PRP was
prepared. Ten microliters of stock PPE samples (in duplicate) were
incubated with 90 uL of PRP in 1.5 mL polystyrene tube for 1 h at
37 °C. A small aliquot of the platelet suspension (5 μL)
was mixed with 2.5 μL mouse antibody monoclonal CD62P PE in
45 μL of autologous plasma pH 7.4. Platelet activation was analyzed
by flow cytometry (BD, FACS Canto II), and 10,000 events were recorded
for each run. The mouse monoclonal anti-CD42a-FITC human antibody
was incubated also in the same proportion with the PRP to confirm
the presence of the platelet in the flow gate. The 1 mM TRAP6 was
used as a positive control for platelet activation; 45 μL of
PRP were incubated with 5 μL of thrombin receptor-activated
peptide (TRAP) for 15 min at room temperature.
Activated
Partial Thromboplastin Time and
Prothrombin Time Analysis
The activated partial thromboplastin
time (APPT) and prothrombin time (PT) assay were used to monitor the
effect of PPE on blood coagulation. The polymer stock solution (25
μL) was mixed with the PPP (225 μL) at 37 °C. Saline
solution was used as the normal control. Coagulation initiation reagents
actin FSL and Innovin were used for APTT and PT analyses, respectively.
Triplicate samples were tested on the STart4 coagulometer (Diagnostica
Stago, France) using plasma from three separate donors, and the average ±
SD was reported.
Rotational Thromboelastometry
Analysis
The rotational thromboelastometry (ROTEM) system
(ROTEM-delta) was used for this coagulation study.
Sodium citrate anticoagulated
whole blood fresh collected (within 15 min) (360 μL) was mixed
with the saline control or stock PPE solutions (40 μL) (9:1
v/v). The blood–polymer mixture (340 μL) was transferred
into the ROTEM cup. The coagulation was initiated by adding 20 μL
of 0.2 M calcium chloride solution. The ROTEM clot’s physical
and kinetic properties were analyzed for three donors.
Red Blood Cell Aggregation and Hemolysis
Citrate anticoagulated
whole blood or red cells (10% hematocrit)
washed in phosphate buffer were used for these studies. The PPE sample
(20 μL) or saline control was incubated with 180 μL of
red blood cell samples for 1 h at 37 °C. For the aggregation
study, the cells were fixed with 2% glutaraldehyde in saline (2 h
incubation at room temperature). The blood cell morphology was assessed
using a bright-field light microscope (Zeiss Axioskop 2 Plus, 40×
magnifications) with a digital microscope camera (AxioCam ICC 1, Carl
Zeiss Microimaging Inc.) attached to it. For the hemolysis study,
RBCs incubated with distilled H2O were used as the positive
control (100% lysis). The percentage of RBC lysis was measured on
a 96-well plate Spectra Max 190 spectrophotometer using the ferricyanide–cyanide
(Drabkin’s) method. Two microliters of the RBC/PPE mixture
were added to 298 μL of Drabkin’s solution, and the optical
density (OD) at 540 nm of the solution was measured. The remaining
RBC/PPE mixture was centrifuged, and 50 μL of the supernatant
was added to 250 μL of Drabkin’s solution. The OD of
the solution was measured using Drabkin’s reagent as a blank.
The percentage of lysed cells was calculated from the ratio of hemoglobin
present in the supernatant and the total hemoglobin.
Results and Discussion
Synthesis and Characterization
of PPEs and
Nanocarriers
In the present work, a set of PPEs (Figure ) was synthesized
via ring-opening polymerization of cyclic phosphates or phosphonates,
and the PPE polymers were characterized for their purity, molar mass,
and molar mass dispersity. The PPE-coated nanocarriers were prepared
by aza-Michael addition between the amino group on the polystyrene
surface and poly(ethyl ethylene phosphonate) (PEtEP), which was previously
ω-functionalized with commercial 4-(maleinimido)phenyl isocyanate
(Figure ). More details
about the samples and their main features are shown in Table .
R = −CH2CH3, −CH2CH2CH2CH3Mn: 10 kDa; DPn: 71; 36 (−CH2CH3) and 31 (−CH2CH2CH2CH3)
PEG
5a
polyethylene glycol (PEG)
Mn: 8 kDa; DPn: 133
5b
polyethylene glycol (PEG)
Mn: 20 kDa; DPn: 333
5c
polyethylene glycol (PEG)
Mn: 35 kDa; DPn: 583
PPE-functionalized PS-NPs
6
PS nanoparticles functionalized
with PEtEP
PEtEP:
R = −CH2CH3; Mn: 8.4 kDa; DPn: 59; number of polymers attached to each
particle: 4000
Set of samples analyzed
in this work.
Blood Compatibility Studies of PPEs
The influence of
polymers on blood coagulation, as well as the interaction
with platelets and RBCs were recently investigated in various polymers
proposed for biomedical applications.[18−21] In the current work, hemocompatibility
assays were performed on the samples using fresh blood collected from
consented donors at the University of British Columbia.
Influence of Blood Coagulation
The influence of PPEs
on blood coagulation was investigated by a
number of assays including the measurement of plasma clotting times
and whole blood clotting in human blood. The pro- or anticoagulant
nature of the PPE polymers was measured using two clinical coagulation
assays: PT (Figure a) and APTT (Figure b) in human plasma. The data showed no significant changes in the
blood coagulation behavior at any of the concentrations tested (0.1
to 1 mg/mL final concentration) with respect to the buffer-incubated
plasma control, differently from the positive control (heparin, UFH),
which showed an anticoagulant effect in the APTT assay.
Figure 2
Effect of PPE
polymers on (a) PT and (b) APTT at different concentrations
(0.1, 0.5, and 1 mg/mL). The clotting time was normalized for the
saline control run for each sample (33.2 ± 2.8 s for APTT and
9.8 ± 1.1 s for PT analysis). Unfractionated heparin (UFH) was
used as a control. The data have been obtained by analyzing the blood
of three different donors (N = 3).
Effect of PPE
polymers on (a) PT and (b) APTT at different concentrations
(0.1, 0.5, and 1 mg/mL). The clotting time was normalized for the
saline control run for each sample (33.2 ± 2.8 s for APTT and
9.8 ± 1.1 s for PT analysis). Unfractionated heparin (UFH) was
used as a control. The data have been obtained by analyzing the blood
of three different donors (N = 3).To further investigate the influence of PPEs on whole blood
coagulation,
ROTEM was used.[22] Whole blood samples (N = 3, independent donors) were incubated with different
PPEs at 1 mg/mL concentration, and the clotting parameters were measured,
including the “R” time, “K” values, and
angles and maximum clot firmness (MA) (Figure a). We also measured the influence of PPEs
incubated in buffer for 2 weeks and then used for ROTEM measurements
to understand whether polymer degradation influences blood coagulation.
The ROTEM profile of sample #1 is shown in Figure b, and the others are reported in the Supporting
Information, Figure S2. As shown in the
figure, the PPEs did not modify any of the ROTEM parameters, even
in their degraded form (measurements of samples after 2 weeks of incubation
in buffer), suggesting that the PPEs do not influence the whole blood
clot formation. Only sample #4 at a concentration of 1 mg/mL showed
an unusual ROTEM profile (Supporting Information Figure S2), similar to that shown by amphiphilic polymers
such as poly(N-isopropylacrylamide).[18] Nevertheless, it is important to note that this sample
at lower concentrations did not modify the blood clotting profile.
Figure 3
Whole
blood coagulation studied using ROTEM in the presence of
PPEs. (a) Reaction time (R), time for the first significant clot formation,
K (achievement of certain clot firmness, angle (kinetics of clot development),
and MA (maximum amplitude–maximum strength of clot). (b) ROTEM
profile of sample #1 at 1 mg/mL (as made (blue), 2 weeks (green),
and saline control (pink)).
Whole
blood coagulation studied using ROTEM in the presence of
PPEs. (a) Reaction time (R), time for the first significant clot formation,
K (achievement of certain clot firmness, angle (kinetics of clot development),
and MA (maximum amplitude–maximum strength of clot). (b) ROTEM
profile of sample #1 at 1 mg/mL (as made (blue), 2 weeks (green),
and saline control (pink)).
Platelet Interaction with PPEs
In support
of the whole blood clotting profile previously shown,
we next investigated the interaction of platelets with PPEs by measuring
the platelet activation using a flow cytometer in PRP. We measured
the activation marker CD62P on the platelets’ surface using
an anti-CD62P antibody. The data obtained are reported in Figure . We observed that
the PPE samples did not show any significant platelet activation at
any concentration, confirming the absence of unfavorable polymer interactions
with the platelets. The interaction was almost unaffected by changes
in the PPE polymer hydrophilicity (polymers #1, #2b, #4) or molar
mass (polymers #2a–c).
Figure 4
Platelet activation in the presence of the PPE
polymers at different
concentrations, observed by measuring the expression of the activation
marker CD62P on the surface of platelets using flow cytometry analysis.
Saline solution and TRAP have been used as, respectively, negative
and positive controls for the experiment.
Platelet activation in the presence of the PPE
polymers at different
concentrations, observed by measuring the expression of the activation
marker CD62P on the surface of platelets using flow cytometry analysis.
Saline solution and TRAP have been used as, respectively, negative
and positive controls for the experiment.
RBC Aggregation and Hemolysis in the Presence
of PPEs
Furthermore, we investigated the interaction of PPEs
with RBCs by measuring their lysis in whole blood and by observing
the RBC aggregation by optical microscopy.[21] The PPE behavior was compared to PEG chains with different molar
masses (8, 20, or 35 kDa, see Table ), with the aim to evaluate the potentialities of PPEs
as PEG substitutes in the biomedical field. The results are reported
in Figure .
Figure 5
(a) Lysis of
RBC after incubation with the tested PPE polymers
at different concentrations (0.1, 0.5, and 1 mg/mL); saline solution
and deuterated water (D2O) were used as, respectively,
negative and positive controls for the experiment. (b) Representative
images obtained by optical microscopy, showing RBC aggregation in
the presence of sample #1 (magnification: 40×). The sample does
not show any detectable aggregation at all the concentrations tested
(0.1, 0.5, and 1 mg/mL), in comparison to the saline control shown
on the left. The optical micrographs recorded for the other samples
are reported in the Supporting Information, Figure S3.
(a) Lysis of
RBC after incubation with the tested PPE polymers
at different concentrations (0.1, 0.5, and 1 mg/mL); saline solution
and deuterated water (D2O) were used as, respectively,
negative and positive controls for the experiment. (b) Representative
images obtained by optical microscopy, showing RBC aggregation in
the presence of sample #1 (magnification: 40×). The sample does
not show any detectable aggregation at all the concentrations tested
(0.1, 0.5, and 1 mg/mL), in comparison to the saline control shown
on the left. The optical micrographs recorded for the other samples
are reported in the Supporting Information, Figure S3.Linear hydrophilic polymers (e.g.,
dextran ≥40 kDa) are
known to promote RBC aggregation by adsorbing to their surface and
forming bridges between the cells.[23] On
the contrary, PPEs induced negligible cells’ lysis at all the
concentrations tested (Figure a), showing comparable results to PEG samples (#5a–c).
Moreover, we did not detect any RBC aggregation or crenation by optical
microscopy in the PPEs (Figure b), except for sample #4 at 1 mg/mL concentration, which showed
slight aggregation in the more concentrated solution (1 mg/mL, see
the Supporting Information Figure S3).
This behavior, in agreement with the unusual ROTEM profile observed
above, was probably related to the increased hydrophobicity of sample
#4, given by the presence of butyl residues in the polymer lateral
chain (see Figure ). We assume that RBC interactions with PPEs depend on the PPE functionalization
and hydrophilicity, especially at high concentrations. However, we
did not observe any dependence on the polymer molar mass.
Blood Compatibility of PPE-Coated Nanocarriers
Having obtained promising results for water-soluble PPEs, we also
performed first investigations on polystyrene nanoparticles (NPs)
coated with PPEs as model nanocarriers for drug loading in biomedical
applications. Such model nanocarriers were studied before with respect
to cellular uptake and protein adsorption and showed stealth properties
similar to their PEGylated analogues.[24] The functionalized NPs exhibited good antithrombogenicity, absence
of RBC lysis, and unaltered blood viscoelastic parameters, calculated
by ROTEM analysis (Figure and Figure S4), even though small
light crenation was observed in the blood cells by optical microscopy
(Figure S3). Overall, the data set acquired
confirmed the high potential of PPE-functionalized NPs for biomedical
applications, as at this preliminary stage, they showed satisfactory
hemocompatibility data. Further analyses, for a deeper understanding
of their interaction with different blood cells and proteins, were
beyond the scope of this work and will be the object of future investigations.
Figure 6
(a) Lysis
of RBCs after incubation with sample #6. Effect of sample
#6 on (b) APTT and (c) PT. The clotting time was normalized for the
saline control run for each sample. The data have been obtained by
analyzing the blood of three different donors (N =
3).
(a) Lysis
of RBCs after incubation with sample #6. Effect of sample
#6 on (b) APTT and (c) PT. The clotting time was normalized for the
saline control run for each sample. The data have been obtained by
analyzing the blood of three different donors (N =
3).
Conclusions
We report a systematic study of blood compatibility for a set of
hydrophilic PPEs with different hydrophilicities and molar masses.
We found high hemocompatibility for all the investigated PPE-samples,
which did not alter the blood coagulation profile, and induced negligible
platelet activation, RBC lysis, or aggregation. Changes in the molar
mass (samples #2a–c) did not influence polymer hemocompatibility.
The more hydrophobic copolymer (sample #4) presented some changes
in the whole blood clot strength at the highest concentration; nonetheless,
it was still very compatible at the concentrations usually needed
for biomedical applications (<1 mg/mL). The conjugation of PPEs
to polystyrene nanoparticles, proposed as model drug nanocarriers,
at a first glance, did not alter their hemocompatibility, even though
small light crenation of the RBCs incubated with the NPs 0.1% w/w
was observed by optical microscopy. These results underline that hydrophilic
PPEs are promising, biodegradable substitutes to currently used PEG,
which might cause side effects in some patients.[15,25] We believe that the data presented herein will further stimulate
the use of PPEs in biomedical and translational studies for fully
degradable drug formulations without negative immune responses.
Authors: Muhammad Imran ul-haq; Benjamin F L Lai; Rafi Chapanian; Jayachandran N Kizhakkedathu Journal: Biomaterials Date: 2012-09-25 Impact factor: 12.479