| Literature DB >> 35185363 |
Markus Pirklbauer1, Martin Berger1, Miro D Boban1, Martin Tiefenthaler1.
Abstract
Introduction: Ultrasound-guided percutaneous kidney allograft biopsy is the gold-standard for pathology work-up. Recent studies postulate better safety and efficacy for tangential approaches, however, there is no recommendation regarding biopsy needle path. In this context, we previously described the unified tangential extraperitoneal retrorenal (TER) approach for standard allograft biopsy.Entities:
Keywords: adequacy rate; complication rate; percutaneous kidney transplant biopsy; tangential extraperitoneal retrorenal approach; ultrasound-guided biopsy
Mesh:
Year: 2022 PMID: 35185363 PMCID: PMC8842347 DOI: 10.3389/ti.2021.10068
Source DB: PubMed Journal: Transpl Int ISSN: 0934-0874 Impact factor: 3.782
FIGURE 1Anatomic landmarks of real-time ultrasound-guided kidney allograft biopsy. Ultrasound image of the right iliac kidney allograft; TER, tangential, extraperitoneal, retrorenal; G, gauge.
FIGURE 2TER biopsy of right iliac kidney allograft. TER, tangential, extraperitoneal, retrorenal; G, gauge.
Patient characteristics.
| Patients | 250 |
| Male | 155 (62.0) |
| Female | 95 (38.0) |
| No. of performed biopsies | 330 |
| On male patients | 203 (61.5) |
| On female patients | 127 (38.5) |
| Per patient | |
| 1 | 194 (77.6) |
| 2 | 39 (15.6) |
| 3 | 11 (4.4) |
| 4 | 5 (2.0) |
| 5 | 1 (0.4) |
| No. of kidney transplant | 1.41 ± 0.8 (1–7) |
| Age (years) | 50 (18–78) |
| Body Mass Index (kg/m2) | 24.3 (15.6–42.0) |
| Arterial hypertension (≥140/90 mmHg) | 291 (88.2) |
| Diabetes mellitus | 76 (23.0) |
| Arterial hypertension and diabetes mellitus | 69 (20.9) |
Data are presented as numbers (percent), mean ± standard deviation (range), or median (range) for age and body mass index.
No., number.
Biopsy characteristics.
| No. of performed biopsies | 330 |
| No. of biopsy attempts per biopsy | |
| 1 | 28 (8.5) |
| 2 | 237 (71.8) |
| 3 | 57 (17.3) |
| 4 | 4 (1.2) |
| 5 | 4 (1.2) |
| No. of biopsy attempts | 2.2 ± 0.6 (1–5) |
| Total | 709 |
| No. of samples recovered | 1.9 ± 0.5 (1–5) |
| Total | 637 (89.9) |
| No. of biopsy attempts without recovery of sample | 72 (10.2) |
| Biopsy technique | |
| No. of performed biopsies | 330 |
| Using TER approach | 317 (96.1) |
| Using modified TER approach | 13 (3.9) |
| No. of biopsy attempts | 709 |
| Using TER approach | 683 (96.3) |
| Using modified TER approach | 26 (3.7) |
Data are displayed as number (percent) or mean ± standard deviation (range).
ND, no data; No., number.
Biopsy complications.
| TER + modified TER | TER only | |||
|---|---|---|---|---|
| 709 biopsy attempts | 330 biopsies | 683 biopsy attempts | 317 biopsies | |
| Overall | ||||
| Minor | 149 (21.0) | 149 (45.2) | 141 (20.6) | 141 (44.5) |
| Major | 4 (0.6) | 4 (1.2) | 2 (0.3) | 2 (0.6) |
| Total | 153 (21.6) | 153 (46.4) | 143 (20.9) | 143 (45.1) |
| Periprocedural minor complications | ||||
| Drainage of serous fluid | 2 (0.3) | 2 (0.6) | 2 (0.3) | 2 (0.6) |
| Vasovagal reaction | 5 (0.7) | 5 (1.5) | 5 (0.7) | 5 (1.6) |
| Hypertensive urgency | 1 (0.1) | 1 (0.3) | 1 (0.2) | 1 (0.3) |
| Superficial bleeding | 21 (3.0) | 21 (6.4) | 19 (2.8) | 19 (6.0) |
| Postprocedural minor complications | ||||
| Gross hematuria | 10 (1.4) | 10 (3.0) | 10 (1.5) | 10 (3.2) |
| Arteriovenous fistula | 18 (2.5) | 18 (5.5) | 18 (2.6) | 18 (5.7) |
| Subcapsular hematoma | 7 (1.0) | 7 (2.1) | 6 (0.9) | 6 (1.9) |
| Perinephric hematoma | 82 (11.6) | 82 (24.9) | 78 (11.4) | 78 (24.6) |
| <3 × 1 cm | 69 (9.7) | 69 (20.9) | 66 (9.7) | 66 (20.8) |
| >3 × 1 cm | 8 (1.1) | 8 (2.4) | 7 (1.0) | 7 (2.2) |
| ND | 5 (0.7) | 5 (1.5) | 5 (0.7) | 5 (1.6) |
| Pain | 2 (0.3) | 2 (0.6) | 1 (0.2) | 1 (0.3) |
| Deep vein thrombosis | 1 (0.1) | 1 (0.3) | 1 (0.2) | 1 (0.3) |
| Major complications | ||||
| Rinsing catheter for gross hematuria | 1 (0.1) | 1 (0.3) | 1 (0.2) | 1 (0.3) |
| Transfusion | 2 (0.3) | 2 (0.6) | 1 (0.2) | 1 (0.3) |
| Coiling/arterial embolization | 1 (0.1) | 1 (0.3) | 0 (0.0) | 0 (0.0) |
No ultrasound correlate.
Data are displayed as number (percent).
ND, no data; No., number.
Sample adequacy.
| No. of performed biopsies | 330 |
| No. of analyzed samples | |
| 0 | 2 (0.6) |
| 1 | 174 (52.7) |
| 2 | 150 (45.5) |
| 3 | 2 (0.6) |
| ND | 2 (0.6) |
| No. of biopsies considered | |
| Adequate | 192 (58.2) |
| Minimal | 94 (28.5) |
| Inadequate | 42 (12.7) |
| ND | 2 (0.6) |
| Adequate and minimal | 286 (86.7) |
| If 1 sample analyzed | 143 (82.2) |
| If 2 samples analyzed | 141 (94.0) |
| If 3 samples analyzed | 2 (100.0) |
| If 2 or 3 samples analyzed | 143 (94.1) |
| No. of glomeruli | 15.7 ± 9.3 (0–69) |
| No. of arteries | 2.5 ± 1.6 (0–10) |
Data are displayed as number (percent) or mean ± standard deviation (range).
ND, no data; No., number.
FIGURE 3Color-duplex ultrasound image of right iliac kidney allograft and dislocated inferior epigastric artery. TER, tangential, extraperitoneal, retrorenal.