| Literature DB >> 3518533 |
Z Gamulin, J C Brückner, A Forster, F Simonet, J C Rouge.
Abstract
We report a case of a young female who developed multiple life threatening complications after a single internal jugular vein catheterisation. They consisted of pleural misplacement of the catheter, massive haemorrhage with cardiovascular collapse following catheter removal, and development of arteriovenous fistula, diagnosed 18 months later.Entities:
Mesh:
Year: 1986 PMID: 3518533 DOI: 10.1111/j.1365-2044.1986.tb13229.x
Source DB: PubMed Journal: Anaesthesia ISSN: 0003-2409 Impact factor: 6.955