Automated breast sonography using a 7.5-MHz PVDF transducer: preliminary clinical evaluation. Work in progress.

V P Jackson, E Kelly-Fry, P A Rothschild, R W Holden, S A Clark.   

Abstract

Breast ultrasound imaging performed with an automated machine was carried out in 89 patients, and images obtained with a conventional ceramic single-focus 4-MHz transducer and a 7.5-MHz polyvinylidene fluoride (PVDF) transducer were compared. The 7.5-MHz PVDF transducer improved overall image quality in 77% of patients and had equal penetration in 83%. It yielded greatly increased diagnostic information in 43% of 81 masses and improved visualization of calcification in 57% of 14 lesions in which calcium was visible on mammograms.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3517952     DOI: 10.1148/radiology.159.3.3517952

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  [Breast sonographic imaging and evaluation of microcalcifications].

Authors:  W Leucht; D Rabe; G Bastert
Journal:  Arch Gynecol Obstet       Date:  1989       Impact factor: 2.344

Review 2.  Automated breast ultrasound: basic principles and emerging clinical applications.

Authors:  Martina Zanotel; Iliana Bednarova; Viviana Londero; Anna Linda; Michele Lorenzon; Rossano Girometti; Chiara Zuiani
Journal:  Radiol Med       Date:  2017-08-28       Impact factor: 3.469

3.  Optimal scanning technique to cover the whole breast using an automated breast volume scanner.

Authors:  Mitsuhiro Tozaki; Sachiko Isobe; Miki Yamaguchi; Yukari Ogawa; Masami Kohara; Chanwoong Joo; Eisuke Fukuma
Journal:  Jpn J Radiol       Date:  2010-05-29       Impact factor: 2.374

4.  The value of coronal view as a stand-alone assessment in women undergoing automated breast ultrasound.

Authors:  Simone Schiaffino; Licia Gristina; Simona Tosto; Elena Massone; Sara De Giorgis; Alessandro Garlaschi; Alberto Tagliafico; Massimo Calabrese
Journal:  Radiol Med       Date:  2020-07-16       Impact factor: 3.469

Review 5.  Current status of automated breast ultrasonography.

Authors:  Hee Jung Shin; Hak Hee Kim; Joo Hee Cha
Journal:  Ultrasonography       Date:  2015-03-23

6.  Combined use of the automated breast volume scanner and the US elastography for the differentiation of benign from malignant lesions of the breast.

Authors:  Chaoli Xu; Shuping Wei; Yingdong Xie; Xiaoxiang Guan; Ninghua Fu; Pengfei Huang; Bin Yang
Journal:  BMC Cancer       Date:  2014-11-03       Impact factor: 4.430

  6 in total