BACKGROUND AND
OBJECTIVE: Heart rate variability (HRV) has been proposed as a useful marker that can show the performance adaptation and optimize the training process in elite athletes. The development of wearable technology permits the measurement of this marker through smartphone applications. The purpose of this study is to assess the validity and reliability of short and ultra-short HRV measurements in elite cyclists using different smartphone applications.
METHOD: Twenty-six professional cyclists were measured at rest in supine and in seated positions through the simultaneous use of an electrocardiogram and two different smartphone applications that implement different technologies to measure HRV: Elite HRV (with a chest strap) and Welltory (photoplethysmography). Level of significance was set at p < 0.05.
RESULTS: Compared to an electrocardiogram, Elite HRV and Welltory showed no differences neither in supine nor in seated positions (p > 0.05) and they showed very strong to almost perfect correlation levels (r = 0.77 to 0.94). Furthermore, no differences were found between short (5 min) and ultra-short (1 min) length measurements. Intraclass correlation coefficient showed good to excellent reliability and the standard error of measurement remained lower than 6%.
CONCLUSION: Both smartphone applications can be implemented to monitor HRV using short- and ultra-short length measurements in elite endurance athletes.
Copyright © 2022. Published by Elsevier B.V.

Entities:  

Keywords:  App, Heart rate variability; Exercise; Ultra-short

Mesh:

Year:  2022        PMID: 35172251     DOI: 10.1016/j.cmpb.2022.106696

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  1 in total

1.  Validity of the Polar H10 Sensor for Heart Rate Variability Analysis during Resting State and Incremental Exercise in Recreational Men and Women.

Authors:  Marcelle Schaffarczyk; Bruce Rogers; Rüdiger Reer; Thomas Gronwald
Journal:  Sensors (Basel)       Date:  2022-08-30       Impact factor: 3.847

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.