Literature DB >> 35169033

Radial artery diameter: a comprehensive systematic review of anatomy.

Waseem Wahood1, Sherief Ghozy2, Abdulaziz Al-Abdulghani3, David F Kallmes2.   

Abstract

AIMS: The objective of this systematic review is to determine with the highest accuracy the average radial artery (RA) diameter overall and in certain subgroups. The aim of this study is to provide assistance in the development of fitting transradial devices, an increasingly popular intervention.
METHODS: Several databases were used to extract appropriate studies highlighting RA diameter. Databases used in the generation of this study were Ovid EBM Reviews, Ovid Embase, Ovid Medline, Scopus and Web of Science Core Collection. RA diameter was determined overall, in males versus females, adults only, adults+children, in the presence of comorbidities, and finally RA diameter in the context of various vasodilators.
RESULTS: A total of 71 studies were included. The average RA diameter overall was determined to be 2.62±0.15 mm in children+adults and 2.70±0.15 mm in adults only. In comparison to an RA diameter of 2.68±0.24 mm in adult males, the diameter was found to be 2.27±0.27 mm in adult females (p=0.028). As for comorbidities, the mean RA diameter in adult patients with hypertension and congestive heart failure was 2.72±0.37 mm and 2.80±0.25 mm, respectively. Finally, the mean RA diameter with nitrate and angiotensin-converting enzyme (ACE) inhibitor use was 2.97±0.53 mm and 2.82±0.29 mm respectively. For comparison, the average outer diameter of a 5 French introducer sheath is 2.29 mm and a 6 French introducer sheath is 2.62 mm.
CONCLUSIONS: The findings presented in this study will help determine the most appropriate transradial device to use in several different populations in the context of vasodilator usage or the absence thereof. © Author(s) (or their employer(s)) 2022. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  pharmacology; statistics; vessel wall

Year:  2022        PMID: 35169033     DOI: 10.1136/neurintsurg-2021-018534

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  2 in total

1.  Radial artery lumen diameter and intima thickness in patients with abdominal aortic aneurysm.

Authors:  Kristian Shlimon; Marcus Lindenberger; Martin Welander; Frida Dangardt; Niclas Bjarnegård
Journal:  JVS Vasc Sci       Date:  2022-08-06

2.  Simultaneous Dual Distal Radial Balloon Aortic Valvuloplasty for Larger Aortic Annuli.

Authors:  Alexandru Achim; Viktor Sasi; Tamás Szűcsborus; Kornél Kákonyi; Zoltan Ruzsa
Journal:  Methodist Debakey Cardiovasc J       Date:  2022-09-29
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.