Literature DB >> 3516738

Maxillary and sinus implant reconstructions.

H Tatum.   

Abstract

The root and sinus series of the Omnii system have been used extensively since 1981. They are very versatile in their ability to be used within edentulous areas of the maxilla. Their design attempts to maximize the use of the available bone, and placement techniques allow the manipulation of bone to form sockets in otherwise deficient areas of bone. The root implants can be used as free-standing implants or as multiple abutments. The sinus implant is always used as an abutment. It may be used in conjunction with other implants or with natural abutments. Maxillary implants are not loaded until a 6-month healing time has elapsed following placement. An understanding of the different qualities of bone found in the maxilla is important to achieving the successful loading of these implants. Different times are required to allow physiologic loading in different qualities of maxillary bone. Restorative treatment is normally done with fixed bridge work, and the use of any type of stress breaker attachments is not recommended.

Mesh:

Substances:

Year:  1986        PMID: 3516738

Source DB:  PubMed          Journal:  Dent Clin North Am        ISSN: 0011-8532


  184 in total

Review 1.  Role of implant diameter on long-term survival of dental implants placed in posterior maxilla: a systematic review.

Authors:  Fawad Javed; Georgios E Romanos
Journal:  Clin Oral Investig       Date:  2014-11-01       Impact factor: 3.573

2.  [The use of a resorbable, synthetic membrane for the elevation of the sinus floor].

Authors:  Alexander C Kübler; Jörg Neugebauer; Viktor Karapetian; Jung-Hwan Oh; Martin Scheer; Joachim E Zöller
Journal:  Mund Kiefer Gesichtschir       Date:  2004-05-01

3.  Management of the Schneiderian membrane perforation during the maxillary sinus elevation procedure: a case report.

Authors:  Deborah Meleo; Francesca Mangione; Sergio Corbi; Luciano Pacifici
Journal:  Ann Stomatol (Roma)       Date:  2012-05-03

4.  Benign paroxysmal positional vertigo as a complication of sinus floor elevation.

Authors:  Moon-Sun Kim; Jae-Kwan Lee; Beom-Seok Chang; Heung-Sik Um
Journal:  J Periodontal Implant Sci       Date:  2010-04-15       Impact factor: 2.614

5.  Maxillary Sinus Augmentation with Autologous and Heterologous Bone Graft: A Clinical and Radiographic Report of Immediate and Delayed Implant Placement.

Authors:  Mario Santagata; Umberto Tozzi; Gianpaolo Tartaro; Vincenzo Santillo; Corrado Giovanni; Ettore Lamart; Angelo Itro; Giuseppe Colella; Salvatore D'Amato
Journal:  J Maxillofac Oral Surg       Date:  2013-08-30

6.  Alveolar ridge split technique for implant placement.

Authors:  Vimal Arora; Dinesh Kumar
Journal:  Med J Armed Forces India       Date:  2014-03-12

7.  The influence of bone substitute materials on the bone volume after maxillary sinus augmentation: a microcomputerized tomography study.

Authors:  Sebastian Kühl; Christoph Brochhausen; Hermann Götz; Andreas Filippi; Michael Payer; Bernd d'Hoedt; Matthias Kreisler
Journal:  Clin Oral Investig       Date:  2012-04-27       Impact factor: 3.573

8.  Erbium, chromium:yttrium-scandium-gallium-garnet laser-assisted sinus graft procedure.

Authors:  Dong-Seok Sohn; Ji-Soo Lee; Kyung-Mi An; George E Romanos
Journal:  Lasers Med Sci       Date:  2009-02-14       Impact factor: 3.161

9.  The use of mineralized bone allograft as a single grafting material in maxillary sinus lifting with severely atrophied alveolar ridge (1-3 mm) and immediately inserted dental implants. A 3- up to 8-year retrospective study.

Authors:  Ioannis Tilaveridis; Maria Lazaridou; Lambros Zouloumis; Ioannis Dimitrakopoulos; Vasilis Tilaveridis; Sofia Tilaveridou
Journal:  Oral Maxillofac Surg       Date:  2018-06-01

10.  Histologic and histomorphometric results of three bone graft substitutes after sinus augmentation in humans.

Authors:  Marzia Pettinicchio; Tonino Traini; Giovanna Murmura; Sergio Caputi; Marco Degidi; Carlo Mangano; Adriano Piattelli
Journal:  Clin Oral Investig       Date:  2010-11-03       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.