| Literature DB >> 35164702 |
Lu Sun1, Zheng-Xuan Li1, Yun Chen2, Zhi-Qiang He2, Hong-Xin Song3.
Abstract
BACKGROUND: This study aimed to compare the changes in the axial length (AL) in myopic children that wear centered and decentered orthokeratology (Ortho-K).Entities:
Keywords: Axial length elongation; Decentration of Ortho-K lens; Myopia
Mesh:
Year: 2022 PMID: 35164702 PMCID: PMC8845411 DOI: 10.1186/s12886-022-02310-4
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Fig. 1A computer program developed in-house was adopted to measure the distance of ortho-K lens decentration for each subject. The blue ellipse was considered to be the fitting ellipse. The black line represents the decentration distance between the pupil center and the center of the fitted ellipse
Fig. 2Overview of lens decentration for all subjects. Overview of treatment zone Ortho-K lens decentration. The range between 0 and 360° was similar to the meridian degree set on a corneal topography map. Each circle outlines the distances of 0.5 and 1.0 mm to the corneal vertex normal
Biometric measurements of study subjects
| Variables | All | Mildly | Moderately | Severely | |
|---|---|---|---|---|---|
| Age (years) | 12.43 ± 1.73 | 12.49 ± 1.75 | 12.45 ± 1.58 | 12.26 ± 2.10 | 0.621 |
| Gender (male) | 102 (47) | 31 (48) | 56 (49) | 15 (40) | 0.582 |
| SER | -3.10 ± 1.20 | -2.95 ± 1.30 | -3.10 ± 1.20 | -3.30 ± 1.04 | 0.328 |
| SRE | -3.0 ± 1.12 | -2.86 ± 1.16 | -3.01 ± 1.12 | -3.19 ± 1.04 | 0.285 |
| RA | 90 (41) | 28 (43) | 48 (42) | 15 (39) | 0.937 |
| Baseline AL | 24.81 ± 0.83 | 24.75 ± 0.90 | 24.80 ± 0.80 | 24.97 ± 0.77 | 0.417 |
| Flat K | 42.70 ± 1.28 | 42.81 ± 1.49 | 42.69 ± 1.19 | 42.51 ± 1.18 | 0.530 |
| Steep K | 43.66 ± 1.39 | 43.74 ± 1.56 | 43.68 ± 1.33 | 43.45 ± 1.33 | 0.660 |
| DD, mm | 0.69 ± 0.32 | 0.35 ± 0.11 | 0.71 ± 0.13 | 1.21 ± 0.22 | <0.001 |
| DA | 192.43 ± 74.33 | 189.89 ± 76.90 | 188.03 ± 74.17 | 209.94 ± 69.58 | 0.111 |
| Flat E | 0.59 ± 0.14 | 0.61 ± 0.12 | 0.59 ± 0.15 | 0.56 ± 0.15 | 0.324 |
SER Spherical equivalent refractive error, SRE Spherical refractive error, RA Regular astigmatism, AL Axial length, DD Decentered distance, DA Decentered Angle
aAccording to the distribution, Kruskal–Wallis H test or ANOVA was adopted to compare characteristics among the three groups.
Changes in AL from baseline to 12 months after Ortho-K lens wear
| Group | Number | Baseline | 12 months (mm) | AL change |
|---|---|---|---|---|
| Mildly | 65 | 24.75 ± 0.90 | 24.99 ± 0.88 | 0.24 ± 0.21 |
| Moderately | 114 | 24.80 ± 0.80 | 25.03 ± 0.76 | 0.23 ± 0.18 |
| Severely | 38 | 24.97± 0.77 | 25.16 ± 0.78 | 0.19 ± 0.20 |
| / | / | 0.486 |
AL Axial length
Multiple Linear regression of AL changes from baseline to 12 months after Ortho-K lens wear
| Variable | Estimate | Standard error | t value | |
|---|---|---|---|---|
| Intercept | 1.1934 | 0.447 | 2.67 | 0.008 |
| Age (years) | -0.037 | 0.007 | -4.97 | <0.001 |
| Gender (male) | -0.045 | 0.027 | -1.69 | 0.092 |
| Decentration (ref = mild) | ||||
| Moderately | -0.007 | 0.028 | -0.25 | 0.807 |
| Severely | -0.049 | 0.037 | -1.34 | 0.183 |
| Baseline AL | -0.017 | 0.020 | -0.88 | 0.379 |
| SRE | 0.013 | 0.012 | 1.11 | 0.267 |
| RA | 0.003 | 0.026 | 0.10 | 0.917 |
| Flat K | -0.001 | 0.024 | -0.02 | 0.982 |
| Steep K | 0.009 | 0.022 | 0.411 | 0.681 |
AL Axial length
Covariance analysis for changes in AL in children with mildly, moderately, and severely decentered groups
| Variable | Mean square | ||
|---|---|---|---|
| Age (years) | 0.800 | 24.69 | <0.001 |
| Gender (male) | 0.093 | 2.87 | 0.092 |
| Decentration (mildly, moderately, severely) | 0.032 | 1.00 | 0.370 |
| Baseline AL | 0.025 | 0.78 | 0.379 |
| SRE | 0.040 | 1.24 | 0.267 |
| Astigmatism | 0.000 | 0.01 | 0.917 |
AL Axial length