| Literature DB >> 35162615 |
Ana de la Casa Pérez1, Pedro Ángel Latorre Román1, Marcos Muñoz Jiménez2, Manuel Lucena Zurita3, José Alberto Laredo Aguilera4,5, Juan Antonio Párraga Montilla1, José Carlos Cabrera Linares1.
Abstract
BACKGROUND: The aim of this study was to analyse the validity and accuracy of the low-cost Xiaomi Mi Band 4 (MB4) fitness tracker in relation to step count and heart rate in free-living conditions.Entities:
Keywords: Xiaomi Mi Band 4; laboratory and free-living condition; low-cost fitness trackers; physical activity; validity and reliability
Mesh:
Year: 2022 PMID: 35162615 PMCID: PMC8834826 DOI: 10.3390/ijerph19031593
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 3.390
Figure 1Laboratory condition protocol.
Figure 2MB4 validation protocol in free-living condition.
Validation statistics of the steps recorded by comparing the SW monitors and the Xiaomi MB4 wristband.
| Difference Recording Tasks | SW | MB4 | Cohen’s -d | Pearson Correlation Coefficient | ICC | ||
|---|---|---|---|---|---|---|---|
| Number of steps | 13,536.11 (5020.98) | 14,460.38 (5309.96) | 0.095 | 0.178 | 0.818 *** | 0.899 (0.798–0.950) | <0.001 |
| 70 steps per minute | 61.62 (10.04) | 69.41 (12.33) | 0.007 | 0.692 | 0.340 | 0.500 (−0.157–0.784) | 0.052 |
| 90 steps per minute | 83.88 (12.67) | 91.63 (4.64) | <0.001 | 0.812 | 0.595 *** | 0.556 (0.128–0.773) | 0.009 |
| 110 steps per minute | 107.84 (5.19) | 109.90 (2.45) | 0.022 | 0.507 | 0.349 * | 0.425 (−0.165–0.716) | 0.061 |
| 130 steps per minute | 121.73 (8.25) | 119.81 (7.59) | 0.454 | 0.242 | −0.057 | −0.121 (−1.762–0.545) | 0.599 |
| 200 steps in stairs | 194.73 (28.25) | 204.63 (24.19) | 0.081 | 0.376 | 0.356 * | 0.521 (−0.007–0.772) | 0.026 |
70, 90, 110, and 130 steps: cadence of the steps per minute at different intensities; 200 steps: number of steps measured by SW and MB4 during stairs test (upstairs and downstair); SD: standard deviation; * p < 0.05; *** p < 0.001.
Adjustment statistics of the number of steps by the T-test for a sample in relation to the reference steps.
| Step Reference | SW | MB4 |
|---|---|---|
| 200 steps in stairs | −6.78/0.196 | 4.63/0.303 |
| 70 steps per minute | −8.37/<0.001 | −0.58/0.819 |
| 90 steps per minute | −6.11/0.007 | 1.63/0.042 |
| 110 steps per minute | −2.15/0.024 | −0.11/0.779 |
| 130 steps per minute | −8.26/<0.001 | −10.18/<0.001 |
SW: Sense Wear; MB4: Mi band 4.
Figure 3Scatter plots of the steps recorded by the MB4 and SW wristband over 24 h (left) and at 90 steps per minute (right).
Figure 4Number of steps obtained in comfortable and fast gait by MB4 and the target count by video.
Figure 5Bland-Altman plots in the process of calculating the concordance between MB4 and SW in the different gait protocols.
Validation statistics of HR recorded by comparing FB monitors and Xiaomi MB4 wristband.
| Heart Rate at Different Intensities | FB | MB4 | Cohen’s -d | Pearson Correlation Coefficient | CCI | ||
|---|---|---|---|---|---|---|---|
| HR (Bpm) at rest | 75.68 (12.31) | 75.18 (6.94) | 0.768 | 0.050 | 0.702 *** | 0.751 (0.469–0.883) | <0.001 |
| HR (Bpm) at 200 stairs | 105.48 (20.30) | 98.62 (12.94) | 0.053 | 0.402 | 0.468 ** | 0.596 (0.139–0.810) | 0.010 |
| HR (Bpm) at 70 steps/min | 90.68 (18.31) | 94.87 (10.29) | 0.054 | 0.282 | 0.797 *** | 0.810 (0.612–0.907) | <0.001 |
| HR (Bpm) at 90 steps/min | 91.62 (20.05) | 98.58 (13.38) | 0.005 | 0.408 | 0.750 *** | 0.825 (0.646–0.914) | <0.001 |
| HR (Bpm) at 110 steps/min | 97.56 (19.75) | 102.73 (14.40) | 0.043 | 0.299 | 0.688 *** | 0.792 (0.583–0.896) | <0.001 |
| HR (Bpm) at 130 steps/min | 108.30 (18.23) | 106.42 (22.35) | 0.513 | 0.092 | 0.715 *** | 0.824 (0.635–0.915) | <0.001 |
FB: First Beat; MB4: Mi band 4; HR: Heart Rate; SD (standard deviation); Bpm: Beats per minute; ** p < 0.01; *** p < 0.001.
Figure 6Scatter plots of HR recorded by the MB4 wristband and FB heart sensor during (from top to bottom and from left to right): resting, walking at 70–90–110–130 steps per minute and walking up and down 200 stairs.
Figure 7Bland-Altman plots in the process of calculating the concordance between MB4 and FB at rest and in the different gait protocols.