Abstract
The implementation of shape modification (SM) to reinforced concrete (RC) columns has been demonstrated to be effective when enhancing the effectiveness of the fiber-reinforced polymer (FRP) confinement of the columns, particularly for non-circular columns. The SM approach generally includes modifying a square section into a circular one, modifying a rectangular section into an elliptical/oval one and modifying a square/rectangular section into a curvilinearized square/rectangular section. In this paper, a state-of-the-art review of studies on FRP-confined non-circular columns with SM is conducted. The effects of key parameters on the effectiveness of FRP confinement are discussed, and different methods for the implementation of SM in real applications are briefly introduced. The findings of the review further confirm the effectiveness of the SM approach, and the test results demonstrate the effectiveness and advantages of section curvilinearization with a limited increase in cross-sectional area. Additionally, existing theoretical models for FRP-confined concrete in columns with SM are summarized. Further research opportunities associated with FRP-confined non-circular columns with SM are identified.Entities:
Keywords: confinement; fiber-reinforced polymer (FRP); reinforced concrete (RC) column; section curvilinearization (SC); section modification; stress–strain model
Year: 2022 PMID: 35160553 PMCID: PMC8839110 DOI: 10.3390/polym14030564
Source DB: PubMed Journal: Polymers (Basel) ISSN: 2073-4360 Impact factor: 4.329
Figure 1Effectively and ineffectively confined concrete in rectangular columns.
Figure 2Section modification for square/rectangular columns before FRP jacketing.
Figure 3SC for square/rectangular columns before FRP jacketing.
Figure 4Stress–strain of FRP-confined concrete in circular, square and curvilinearized columns [56].
Figure 5Section circularization/ellipticalization based on formwork and fresh concrete/cement mortar.
Figure 6Section circularization/ellipticalization based on pre-cast additional concrete bolsters.
Figure 7Section circularization/ellipticalization based on stay-in-place FRP shells.
Figure 8Section circularization/ellipticalization based on 3D in-site printed concrete/cement mortar bolsters.
Figure 9Novel flexible formwork system for SC [61]. (a) Linking parallel wooden bars with steel strips. (b) Wrapping the flexible formwork around an existing column.
Figure 10SC procedures in practical applications.
Figure 11Circular FCSRCs with different shapes of steel sections and a curvilinearized rectangular FCSRC. (a) Circular FCSRC with a cruciform steel section. (b) Circular FCSRC with an I steel section. (c) Circular FCSRC with a circular steel tube. (d) Curvilinearized rectangular FCSRC.
Figure 12Stress–strain curves of one-layer FRP-confined concrete in elliptical columns (reproduced based on Teng and Lam [43]).
Figure 13Stress–strain curves of FRP-confined concrete in square columns with section circularization (reproduced based on Yan and Pantelides [46]).
Main thematic results for FRP-confined concrete columns with SM.
| References | SCir | SEll | SCurv | Main Thematic Results |
|---|---|---|---|---|
| Priestley and Seible [ | √ | Confinement efficiency for columns with corner rounding was only 50% of that for columns with SCir. | ||
| Teng and Lam [ | √ | The confinement effectiveness decreased with the a/b ratio and the stress–strain curve exhibited a descending branch if the effective confinement ratio was equal to or less than 0.11. A strength model was developed for FRP-confined concrete in elliptical columns. | ||
| Yan et al. [ | √ | √ | SCir/SEll yielded the post-peak hardening behavior of FRP-confined square/rectangular columns. A higher axial compressive strength and higher energy absorption were observed for SM square/rectangular columns with post-tensioned FRP shells compared with members confined using bonded FRP jackets. | |
| Parvin and Schroeder [ | √ | The effectiveness of CFRP wrapping was substantially reduced for eccentric loading compared with concentric loading, and the CFRP jacket was more effective in the axial direction than the CFRP jacket in the hoop direction for eccentrically loaded columns. | ||
| Hadi et al. [ | √ | Both corner rounding and section circularization were effective is enhancing the compressive behavior of FRP-confined concrete in square columns. The added concrete covers effectively enhanced the load carrying capacity of the column by increasing the cross-sectional area and increasing the effectiveness of the FRP confinement. | ||
| Pham et al. [ | √ | Section circularization is effective in enhancing the FRP confinement efficiency. The concrete covers with a higher strength exhibited a higher load-carrying capacity than the concrete covers with a lower strength. | ||
| Hadi and Tran [ | √ | The performances of the original columns were improved significantly after being strengthened using SCir. The columns with SCir with increased FRP thickness helped to relocate the failure of the beam-column connection from the joint location to any preferred location in the beam span. | ||
| Alsayed et al. [ | √ | CFRP confinement increased both the strength and ductility of confined concrete in rectangular RC columns with SE. The stresses in the lateral ties became almost uniform across the cross-section owning to the confinement provided by the CFRP wrap. | ||
| Zeng et al. [ | √ | SCir can significantly improve the effectiveness of FRP confinement. The combination of SCir and the partial use of the FRP strengthening technique saved as much as 50% of the FRP material in the volumetric ratio. | ||
| Youssef et al. [ | √ | The axial stress–strain behavior of circularized square columns had a satisfactory performance, and the crumb rubber concrete was able to exhibit a smoother transition zone than that of conventional concrete. | ||
| Mai et al. [ | √ | SCir combined with intermittent wrapping significantly improved the strength and ductility of square RC columns. | ||
| Pan et al. [ | √ | The strengthening effect decreased with an increase in the slenderness ratio. The load carrying capacity of FRP-wrapped columns was 20% higher than that of an ordinary reinforced concrete column when the slenderness ratio was less than 17.5. | ||
| Lai et al. [ | √ | A CSC exhibits better axial stress–strain behavior than a square column with corner rounding. | ||
| Zhao [ | √ | The maximum gain in compressive strength was 124% for the specimens with a highest | ||
| Zhu et al. [ | √ | The size effect is very limited in these FRP-confined CSCs. The compressive strength of FRP-confined concrete in CSCs can be effectively enhanced by using the SC method, but the ultimate axial strain was not greatly affected. | ||
| Zeng et al. [ | √ | The slope of the linear second segment of the stress–strain curve of FRP-confined concrete in a CRC was much larger than that of the corresponding rectangular column without SCurv. Besides, the ultimate axial stress of FRP-confined concrete in CRCs increased with an increase in the |
Note: SCir—section circularization; SEll—section ellipticalization; SCurv—section curvilinearization; √—applicable.
Figure 14Normalized stress–strain curves of concrete in large-scale CRCs (Zeng et al. [60]). (a) CRCs with different r/s ratios. (b) CRCs with different corner radii.
Figure 15Comparisons of ultimate axial stresses and ultimate axial strains between test results and theoretical predictions (Zeng et al. [85]). (a) Ultimate axial stress. (b) Ultimate axial strain.
Figure 16Comparison of stress–strain curves between the existing design-oriented stress–strain models and the test results of CSCs (Zhu [57]). (a) Small-scale specimens. (b) Large-scale specimens.