| Literature DB >> 35156598 |
Jesse T Jacob1, Craig M Zimring2, Herminia Machry2, Zorana Matić2, Yeinn Oh2, Jennifer R DuBose2, Jill S Morgan3, Kari L Love4.
Abstract
OBJECTIVE: Understand how the built environment can affect safety and efficiency outcomes during doffing of personal protective equipment (PPE) in the context of coronavirus disease 2019 (COVID-19) patient care. STUDYEntities:
Keywords: COVID-19; PPE; built environment; doffing; healthcare design; infectious diseases
Year: 2022 PMID: 35156598 PMCID: PMC8914142 DOI: 10.1017/ice.2021.526
Source DB: PubMed Journal: Infect Control Hosp Epidemiol ISSN: 0899-823X Impact factor: 3.254
Fig. 1.Overview of four study settings, with sites 2a and 2b being different units in the same hospital. Settings varied in layout and configuration of spaces allocated for doffing.
Fig. 2.Number and location of doffing tasks in each site based on observations (16 donning-doffing events). The color intensity of each circle is proportionate to the number of doffing tasks done at that specific area.
Design Features Relevant to COVID-19 PPE Doffing Across Sites: Size and Layout of Doffing Spaces
| Variable | Site 1 | Site 2a | Site 2b | Site 3 |
|---|---|---|---|---|
|
| ||||
| Corridor width (in front of door) | ∼7 ft/2.13 m | ∼8 ft/2.44 m | ∼7–10 ft/2.13–3.05 m | ∼7.5ft/2.28 m |
| Wall width without windows (next to door) | ∼2 ft/0.6 m | ∼2.5 ft/m | ∼8 ft/2.44 m | ∼2 ft |
|
| ||||
| In relation to patient room | Outside | Outside | Inside | Outside |
|
| ||||
| In relation to patient room door | ∼2 ft/0.6 m and at door | ∼4 ft/1.22 m | ∼1/0.3 m ft to left side | ∼1 ft/0.3 m |
| In relation to patient rooms | Between 2 rooms | Between 2 rooms | Between 2 rooms | Between 2 rooms |
|
| ||||
| In relation to patient room door | ∼2 ft/0.6 m | ∼4 ft/1.22 m | ∼2 ft/0.6 m to right side | ∼1 ft/0.3 m and at door |
| In relation to multiple patient rooms | Between 2 rooms | Between 2 rooms | Between 2 rooms | Between 2 rooms |
|
| ||||
| Trash can in relation to patient room | Outside only | Inside/Outside | Inside/Outside | Inside/Outside |
| Trash can in relation to patient room door | <5 ft/1.52 m | < 5 ft /1.52 m | <5 ft/>5 ft/1.52 m | >5 ft/1.52 m |
| Hamper in relation to patient room | Inside only | Inside only | Inside/Outside | Inside only |
| Hamper in relation to patient room door | >5 ft/1.52 m | > 5 ft /1.52 m | >5 ft/<5 ft/1.52 m | >5 ft/1.52 m |
|
| ||||
| In relation to patient room door | ∼14 ft | ∼ 5 ft/1.52 m | ∼7 ft/2.13 m | ∼15 ft/4.57 m |
|
| ||||
| In relation to patient room door | ∼4 ft/1.22 m | >20 ft/6.1 m | >20 ft/6.1 m | >20 ft/6.1 m |
|
| ||||
| Height on wall | ∼3.5 ft/1.07 m | <3.5 ft/1.07 m | <3.5 ft/1.07 m | ∼3.5 feet/1.07 m |
| Access | Obstructed | Not obstructed | Obstructed | Not obstructed |
Patterns Related to Types of PPE Furniture and Supplies Used in COVID-19 PPE Doffing Spaces
| Variable | Subtypes | Site 1 | Site 2a | Site 2b | Site 4 |
|---|---|---|---|---|---|
|
| |||||
| Horizontal surfaces | Mobile cart tops & shelves (Fig. | X | X | ||
| Tabletops (Fig. | X | X | |||
| Vertical storage | Wall-mounted acrylic storage unit (Fig. | X | |||
| Door-mounted fabric storage unit (Fig. | X | ||||
| Pole-mounted fabric storage unit (Fig. | X | ||||
| Designated Containers (Fig. | X | X | |||
| Recessed cabinets (Fig. | X | ||||
| Mobile storage | Mobile cart (Fig. | X | X | ||
| Fixed storage | Fixed table (Fig. | X | X | ||
| PPE storage materials | Hard/Impermeable (Fig. | X | X | X | |
| Soft/porous (Fig. | X | ||||
| Transparent (Fig. | X | X | |||
| Opaque (Fig. | X | X | |||
|
| |||||
| Areas to clean PPE | Presence of designated cleaning space (Fig. | X | |||
| Absence of designated cleaning space (Fig. | X | X | X | ||
| Areas to dry PPE | Hooks on vertical surface (Fig. | X | X | X | |
| Hooks on horizontal surface (Fig. | X | ||||
| Areas for clean and dirty PPE | Cart with clean and dirty separation (Fig. | X | |||
| Cart with no clean and dirty separation (Fig. | X | ||||
| Tabletop with no clean and dirty separation (Fig. | X | X | |||
|
| |||||
| Trash can type | Trash can with lid, tall (Fig. | X | X | ||
| Trash can without lid, short (Fig. | X | ||||
| Trash can without lid, tall and narrow (Fig. | X | X | X | ||
Fig. 3.Different types of PPE storage, work/cleaning surfaces, hangers, and disposals observed across sites: there were various wall-mounted or cart storage and disposal solutions depending on local practices and available wall space and floor space.
Fig. 4.Summary of design goals, guidelines, and strategies for PPE doffing design.