Literature DB >> 35155174

Developing a New Dimension for Fourier Domain Optical Coherence Tomography Images by Simultaneous Measurement of the Refractive Index and Thickness.

Ahmad Amjadi1, Hamed Ghodsi2, Salile Khandani2, Bahareh Khishkhah2, Payman Rajai2, Mohammadreza Razzaghi1.   

Abstract

Introduction: Fourier domain Optical coherence tomography (OCT) is a widely used high-resolution optical imaging technique. It is useful for various applications in medical imaging, such as ophthalmology (e.g. retinal imaging for diagnosing complications like glaucoma or macular degeneration), dermatology, oncology, and cardiology. The ability to noninvasively measure both the refractive index and thickness of biological tissues could have various medical applications and enable earlier disease detection. For example, observing changes in the refractive index can help distinguish between tissues with normal or abnormal function.
Methods: In this study, the theoretical framework for simultaneous measurement of the refractive index and physical thickness of multilayer systems is proposed and tested for two different samples, each having three layers, a glass/NaCl solution/glass sample and a glass/sugar solution/glass sample. The whole signal processing procedure and the experimental setup are described.
Results: The refractive index and thickness of salt water and sugar water samples in the Fourier-domain OCT (FD-OCT) system were obtained. The resulting data were compared with reference measurements and showed a deviation of about 1% for the samples.
Conclusion: We tested the proposed framework for the simultaneous extraction of the refractive index and thickness of multilayer systems of salt water and sugar water from its FD-OCT data. We showed that the measured parameters were in agreement with reference amounts.
Copyright © 2021 J Lasers Med Sci.

Entities:  

Keywords:  Fourier domain OCT; Medical imaging; Ophthalmology; Optical coherence tomography; Refractive index

Year:  2021        PMID: 35155174      PMCID: PMC8837842          DOI: 10.34172/jlms.2021.89

Source DB:  PubMed          Journal:  J Lasers Med Sci        ISSN: 2008-9783


  27 in total

Review 1.  Applications of optical coherence tomography in dermatology.

Authors:  Thilo Gambichler; Georg Moussa; Michael Sand; Daniel Sand; Peter Altmeyer; Klaus Hoffmann
Journal:  J Dermatol Sci       Date:  2005-08-31       Impact factor: 4.563

2.  Sensitivity advantage of swept source and Fourier domain optical coherence tomography.

Authors:  Michael Choma; Marinko Sarunic; Changhuei Yang; Joseph Izatt
Journal:  Opt Express       Date:  2003-09-08       Impact factor: 3.894

3.  Performance of fourier domain vs. time domain optical coherence tomography.

Authors:  R Leitgeb; C Hitzenberger; Adolf Fercher
Journal:  Opt Express       Date:  2003-04-21       Impact factor: 3.894

4.  High-speed optical frequency-domain imaging.

Authors:  S Yun; G Tearney; Johannes de Boer; N Iftimia; B Bouma
Journal:  Opt Express       Date:  2003-11-03       Impact factor: 3.894

Review 5.  Polarization sensitive optical coherence tomography - a review [Invited].

Authors:  Johannes F de Boer; Christoph K Hitzenberger; Yoshiaki Yasuno
Journal:  Biomed Opt Express       Date:  2017-02-24       Impact factor: 3.732

6.  Choroidal thickness and structural glaucoma parameters in glaucomatous, preperimetric glaucomatous, and healthy eyes using swept-source OCT.

Authors:  Handan Akil; Mayss Al-Sheikh; Khalil Ghasemi Falavarjani; Brian Francis; Vikas Chopra
Journal:  Eur J Ophthalmol       Date:  2017-01-16       Impact factor: 2.597

7.  Diagnostic ability of retinal nerve fiber layer imaging by swept-source optical coherence tomography in glaucoma.

Authors:  Zhiyong Yang; Andrew J Tatham; Linda M Zangwill; Robert N Weinreb; Chunwei Zhang; Felipe A Medeiros
Journal:  Am J Ophthalmol       Date:  2014-10-22       Impact factor: 5.258

Review 8.  Optical coherence tomography--current and future applications.

Authors:  Mehreen Adhi; Jay S Duker
Journal:  Curr Opin Ophthalmol       Date:  2013-05       Impact factor: 3.761

Review 9.  Fourier-domain optical coherence tomography: recent advances toward clinical utility.

Authors:  Brett E Bouma; Seok-Hyun Yun; Benjamin J Vakoc; Melissa J Suter; Guillermo J Tearney
Journal:  Curr Opin Biotechnol       Date:  2009-03-04       Impact factor: 9.740

10.  Reference spectrum extraction and fixed-pattern noise removal in optical coherence tomography.

Authors:  Sucbei Moon; Sang-Won Lee; Zhongping Chen
Journal:  Opt Express       Date:  2010-11-22       Impact factor: 3.894

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.