| Literature DB >> 35147767 |
J J Coughlan1, Alp Aytekin1, Erion Xhepa1, Salvatore Cassese1, Michael Joner1,2, Tobias Koch1, Jens Wiebe1, Tobias Lenz1, Tobias Rheude1, Constanza Pellegrini1, Senta Gewalt1, Tareq Ibrahim3, Karl-Ludwig Laugwitz3,2, Heribert Schunkert1,3,2, Adnan Kastrati1,3,2, Sebastian Kufner4.
Abstract
AIMS: To define the incidence of events related to the stented vessel (target vessel related events: TVRE) and events related to non-stented vessels (non-target vessel related events: NTVRE) through to 10-year follow-up in patients post-PCI with newer generation drug eluting stents (DES). METHODS ANDEntities:
Keywords: Atherosclerotic coronary artery disease; Cardiovascular outcomes; Drug eluting stents; Percutaneous coronary intervention; Target vessel
Mesh:
Year: 2022 PMID: 35147767 PMCID: PMC9242894 DOI: 10.1007/s00392-022-01986-4
Source DB: PubMed Journal: Clin Res Cardiol ISSN: 1861-0684 Impact factor: 6.138
Baseline Characteristics as per the event type experienced during 10-year follow-up
| No event | TVRE | NTVRE | Both events | ||
|---|---|---|---|---|---|
| Patients | ( | ( | ( | ( | |
| Age (years) | 68.0 ± 11.3 | 66.4 ± 10.4 | 66.4 ± 10.3 | 66.5 ± 10.4 | < 0.001 |
| Female | 757 (26.5) | 145 (22.1) | 156 (18.1) | 115 (19.8) | < 0.001 |
| Diabetes mellitus | 746 (26.1) | 221 (33.7) | 267 (31.0) | 196 (33.7) | < 0.001 |
| 244 (8.6) | 84 (12.8) | 72 (8.4) | 74 (12.7) | < 0.001 | |
| Hypertension | 1883 (66.0) | 459 (70.0) | 587 (68.3) | 412 (70.8) | 0.046 |
| Current smoker | 472 (16.5) | 108 (16.5) | 153 (17.8) | 93 (16.0) | 0.793 |
| Hypercholesterolemia | 1811 (63.4) | 433 (66.0) | 542 (63.0) | 412 (70.8) | 0.005 |
| Body mass index (kg/m2) * | 27.4 ± 4.5 | 27.8 ± 4.7 | 27.9 ± 4.3 | 27.8 ± 4.0 | 0.007 |
| Prior myocardial infarction | 797 (27.9) | 192 (29.3) | 260 (30.2) | 199 (34.2) | 0.021 |
| Prior aortocoronary bypass surgery | 228 (8.0) | 67 (10.2) | 110 (12.8) | 77 (13.2) | < 0.001 |
| Number of diseased coronary vessels | < 0.001 | ||||
| 568 (19.9) | 102 (15.5) | 60 (7.0) | 29 (5.0) | ||
| 843 (29.5) | 150 (22.9) | 199 (23.1) | 118 (20.3) | ||
| 1444 (50.6) | 404 (61.6) | 601 (69.9) | 435 (74.7) | ||
| Number of lesions | 1.4 ± 0.6 | 1.5 ± 0.7 | 1.4 ± 0.6 | 1.6 ± 0.8 | < 0.001 |
| Clinical presentation | 0.022 | ||||
| 542 (19.0) | 111 (16.9) | 149 (17.3) | 102 (17.5) | ||
| 613 (21.5) | 173 (26.4) | 194 (22.6) | 158 (27.1) | ||
| 1700 (59.2) | 372 (56.7) | 517 (60.1) | 322 (55.3) | ||
| Ejection fraction (%) * | 52.8 ± 12.0 | 53.3 ± 10.7 | 52.5 ± 11.5 | 52.5 ± 10.8 | 0.651 |
| Relook Angiography Performed (As Recommended by Trial Protocols) | 1940 (68.0) | 552 (84.1) | 771 (89.7) | 543 (93.3) | < 0.001 |
Data are mean ± standard deviation or counts (%)
*Missing continuous data:
Body-mass index was not available in 6 patients (5 in the no event group and 1 in the both events group); ejection fraction was not available in 650 patients (356 in the no event group, 85 in the TVRE group, 116 in the NTVRE group and 93 in the both events group). The remaining continuous data were complete
TVRE target vessel related events, NTVRE non-target vessel related events
Angiographic and Procedural Characteristics as per the event type experienced during 10-year follow-up
| No event | TVRE | NTVRE | Both events | ||
|---|---|---|---|---|---|
| Lesions | ( | ( | ( | ( | |
| Stent polymer type | < 0.001 | ||||
| 1290 (33.3) | 309 (31.9) | 411 (35.0) | 319 (35.0) | ||
| 964 (24.9) | 276 (28.5) | 295 (25.1) | 148 (16.2) | ||
| 1615 (41.7) | 385 (39.7) | 467 (39.8) | 445 (48.8) | ||
| Target vessel | < 0.001 | ||||
| 1855 (47.9) | 398 (41.0) | 483 (41.2) | 370 (40.6) | ||
| 925 (23.9) | 231 (23.8) | 320 (27.3) | 298 (32.7) | ||
| 1089 (28.1) | 341 (35.2) | 370 (31.5) | 244 (26.8) | ||
| Chronic total occlusion | 205 (5.3) | 49 (5.1) | 54 (4.6) | 67 (7.4) | 0.037 |
| Complex morphology (B2/C) | 2744 (70.9) | 741 (76.4) | 878 (74.9) | 718 (78.7) | < 0.001 |
| Lesion length (mm) | 15.7 ± 9.2 | 16.1 ± 10.0 | 16.2 ± 9.4 | 16.8 ± 10.0 | 0.005 |
| Vessel size (mm) | 2.8 ± 0.5 | 2.8 ± 0.5 | 2.8 ± 0.5 | 2.7 ± 0.5 | < 0.001 |
| Total stented length (mm) | 24.9 ± 11.6 | 26.5 ± 12.3 | 25.8 ± 12.0 | 26.7 ± 12.6 | < 0.001 |
| Percent stenosis, pre-procedure (%) | 66.7 ± 16.2 | 66.9 ± 16.2 | 66.4 ± 15.8 | 67.4 ± 15.5 | 0.547 |
| Percent stenosis, post-procedure (%) | 11.4 ± 7.3 | 12.4 ± 8.3 | 12.0 ± 7.4 | 12.4 ± 6.9 | < 0.001 |
| Balloon diameter (mm) | 3.1 ± 0.5 | 3.0 ± 0.5 | 3.1 ± 0.5 | 3.0 ± 0.5 | < 0.001 |
| Balloon: Vessel Ratio | 0.41 (0.54) | 0.46 (0.55) | 0.44 (0.55) | 0.27 (0.49) | < 0.001 |
| Maximal Balloon Pressure (mmHg) | 15.4 (3.1) | 15.6 (3.2) | 15.5 (3.1) | 15.8 (3.3) | 0.02 |
Data are mean ± standard deviation or counts (%)
TVRE target vessel related events, NTVRE non-target vessel related events
Fig. 1Cumulative incidence of target vessel and non-target vessel related events through to 10 years post PCI
Target vessel and non-target vessel related events through to 10-years post PCI
| Total patients ( | 4953 | |
|---|---|---|
| Endpoint | Number of Events | Cumulative incidence (%) |
| Target vessel related events | 1238 | 25.8 |
| Non-target vessel related events | 1442 | 30.3 |
| Target vessel myocardial infarction | 210 | 4.4 |
| Non-target vessel myocardial infarction | 78 | 1.7 |
| Target vessel revascularisation | 1123 | 23.4 |
| Non-target vessel revascularisation | 1403 | 29.5 |
Fig. 2Landmark analysis of target vessel and non-target vessel related events from 0–1 and 1–10 years post PCI