Sylwia J Barker1, Laurynas Dagys1, William Hale1,2, Barbara Ripka1, James Eills3,4, Manvendra Sharma1, Malcolm H Levitt1, Marcel Utz1. 1. School of Chemistry, University of Southampton, Southampton SO17 1BJ, United Kingdom. 2. Department of Chemistry, University of Florida, Gainesville 32611, United States. 3. Institute for Physics, Johannes Gutenberg University, D-55090 Mainz, Germany. 4. GSI Helmholtzzentrum für Schwerionenforschung GmbH, Helmholtz-Institut Mainz, 55128 Mainz, Germany.
Abstract
Microfluidic systems hold great potential for the study of live microscopic cultures of cells, tissue samples, and small organisms. Integration of hyperpolarization would enable quantitative studies of metabolism in such volume limited systems by high-resolution NMR spectroscopy. We demonstrate, for the first time, the integrated generation and detection of a hyperpolarized metabolite on a microfluidic chip. The metabolite [1-13C]fumarate is produced in a nuclear hyperpolarized form by (i) introducing para-enriched hydrogen into the solution by diffusion through a polymer membrane, (ii) reaction with a substrate in the presence of a ruthenium-based catalyst, and (iii) conversion of the singlet-polarized reaction product into a magnetized form by the application of a radiofrequency pulse sequence, all on the same microfluidic chip. The microfluidic device delivers a continuous flow of hyperpolarized material at the 2.5 μL/min scale, with a polarization level of 4%. We demonstrate two methods for mitigating singlet-triplet mixing effects which otherwise reduce the achieved polarization level.
Microfluidic systems hold great potential for the study of live microscopic cultures of cells, tissue samples, and small organisms. Integration of hyperpolarization would enable quantitative studies of metabolism in such volume limited systems by high-resolution NMR spectroscopy. We demonstrate, for the first time, the integrated generation and detection of a hyperpolarized metabolite on a microfluidic chip. The metabolite [1-13C]fumarate is produced in a nuclear hyperpolarized form by (i) introducing para-enriched hydrogen into the solution by diffusion through a polymer membrane, (ii) reaction with a substrate in the presence of a ruthenium-based catalyst, and (iii) conversion of the singlet-polarized reaction product into a magnetized form by the application of a radiofrequency pulse sequence, all on the same microfluidic chip. The microfluidic device delivers a continuous flow of hyperpolarized material at the 2.5 μL/min scale, with a polarization level of 4%. We demonstrate two methods for mitigating singlet-triplet mixing effects which otherwise reduce the achieved polarization level.
Nuclear magnetic resonance (NMR) is a
versatile spectroscopic technique,
well-suited for noninvasively probing complex chemical systems and
their dynamic behavior. The sensitivity of NMR is limited by the polarization
of nuclear spins, which is small in thermal equilibrium even at the
largest available magnetic fields. Hyperpolarization methods such
as parahydrogen-induced polarization (PHIP)[1−5] can produce much larger spin alignments in special
cases, offering several orders of magnitude enhancements in sensitivity.
This is particularly attractive in the context of microfluidic lab-on-a-chip
(LoC) devices, where sample volumes are typically of the order of
nL to μL.[6] Such LoC are versatile
platforms on which chemical and biological systems can be studied
under precisely controlled and reproducible conditions. LoC systems
are commonly used as scaffolds for cell[7−11] and organ[12−15] cultures, providing valuable models for supporting the development
of diagnostics,[16,17] therapies[12] and drug safety testing[18,19] but also for
chemical reaction monitoring.[20] While state-of-the-art
micro-NMR probes can provide 1H NMR detection sensitivities
of around for microliter-scale
samples in a 14 T
magnet at thermal equilibrium,[21] this can
be improved into the range of by PHIP.[22] Like
other hyperpolarization methods, PHIP requires specific chemical processes
and spin manipulations to produce hyperpolarized species. LoC devices
can be used to implement some or all of these processes, thus offering
the possibility to integrate production and application of hyperpolarized
species in a single, compact platform.PHIP is conventionally
implemented by bubbling hydrogen gas enriched
in the para spin isomer through a solution containing a suitable substrate
and a catalyst, either directly at high magnetic field (PASADENA experiments)[23] or outside of the magnet at low (μT) fields,
followed by an adiabatic increase of the magnetic field (ALTADENA
experiments).[24] Such experiments are effective
but quite difficult to repeat accurately. This complicates systematic
studies of the interplay between reaction kinetics and nuclear spin
relaxation processes. As we have recently shown, microfluidic implementation
of PHIP at high field allows delivery of the hydrogen gas by diffusion
through a membrane, such that no bubbling is required.[22] Experiments can therefore be carried out under
continuous flow, with a stable stationary level of hyperpolarization
established in the chip. This can be exploited for hyperpolarized
multidimensional NMR experiments, which require superposition of many
transients that must maintain a high level of consistency.In
the following, we use the same approach to probe the formation
of hyperpolarized [1-13C]fumarate from [1-13C]disodium acetylenedicarboxylate in an aqueous solution. To our
knowledge, this is the first demonstration of PHIP-hyperpolarized
metabolite production in a microfluidic device. Hyperpolarized fumarate
is widely used as a contrast agent for in vivo detection of necrosis.[25−35] While the current implementation is not yet ready for use with biological
systems due to the presence of the catalyst and other residues, the
stability of the microfluidic implementation allows systematic studies
of complex kinetic effects.In this work, we generate and observe
solutions of [1-13C]fumarate formed via trans-hydrogenative
PHIP in a microfluidic
chip under continuous-flow conditions, performing the chemical reaction
in one part of the chip and NMR detection in another. The operation
of this device has been discussed in detail elsewhere.[22,35] Briefly, all of our experiments are performed inside of a high field
NMR spectrometer where the reaction solution containing the precursor
and the catalyst is delivered to the chip via a syringe pump. Parahydrogen
is delivered through a separate channel and diffuses through the PDMS
membrane to dissolve into the precursor solution; hence, the hydrogenation
reaction takes place in the chip.Microfluidic technology provides
a convenient platform for studying
hyperpolarized NMR experiments for the following reasons:[6]The results are more reproducible since
hydrogen is brought into solution via diffusion through a membrane,
which is less erratic than bubbling or shaking.[22,36−38]The
reaction kinetics and relaxation
properties do not vary between or during experiments since a steady-state
can be established between the rate of reaction and relaxation, and
this can be finely tuned by, e.g., varying the flow rates used.[22,36−38]The
low volumes used in microfluidics
(in this work a few microliters) makes it more practical to work with
expensive or rare samples.Since fresh reaction solution is continuously
provided to the detection chamber, the samples do not need to be replaced
between experiments.[22,37]Bringing the hyperpolarization step
close to the point of detection minimizes the signal losses due to
relaxation.Singlet–triplet mixing
has been reported to hinder the achievable
polarization of [1-13C]fumarate at high field.[33,39,40] Using our PHIP-on-a-chip system,
we quantify how effectively two different RF pulse methods mitigate
the problem of ST mixing and support our finding with computational
spin dynamics simulations. We present quantitative data on the kinetics
and yield of [1-13C]fumarate from [1-13C]disodium
acetylenedicarboxylate in a microfluidic device.
Background
The
reaction shown in Figure a produces [1-13C]fumarate II by hydrogenation
of [1-13C]disodium acetylenedicarboxylate I with parahydrogen in the presence of a ruthenium catalyst.
The slight magnetic inequivalence due to the difference in 1H–13C J-couplings makes
it possible to convert the singlet order into observable hyperpolarized
magnetization through the use of RF pulse sequences. In this work
we use the singlet-to-magnetization (S2M) pulse sequence for this
task (see Figure e),
which is robust against field inhomogeneities in contrast to alternative
methods.[41] This is important because magnetic
field inhomogeneities are present in the chip due to the differences
in magnetic susceptibility of the chip and the solvent.[42] Applying this sequence after the chemical reaction
with parahydrogen results in high magnetization of the two protons
giving rise to a hyperpolarized substance II*.
Figure 1
(a) Scheme
of the reaction investigated in this work. [1-13C]disodium
acetylenedicarboxylate labeled as molecule I reacts with
parahydrogen in the presence of sodium sulfite and the
catalyst [RuCp*(CH3CN)3]PF6 in D2O at 50 °C. The reaction results in a production of [1-13C]disodium fumarate, molecule II, with the two
protons in a singlet state. Application of the S2M pulse sequence
converts the singlet state into a state that is magnetic and hence
observable, molecule II*. (b) Illustration of an ideal
case where no ST mixing occurs; only the |S0⟩ state is populated. (c) A case where ST mixing occurs leading
to a leak of |S0⟩ state population
to the |T0⟩ state. (d) A case where
the ST mixing is negated by applying a purge pulse prior the S2M,
which distributes the population of the |T0⟩ state to |T+⟩ and |T–⟩ states. (e) S2M pulse sequence
converts the singlet order into observable hyperpolarized magnetization.
The optimal parameters for this molecular system are τ = 15.6
ms, n2 = 14, n1 = 7. (f) Predicted signal intensities for three different scenarios.
(a) Scheme
of the reaction investigated in this work. [1-13C]disodium
acetylenedicarboxylate labeled as molecule I reacts with
parahydrogen in the presence of sodium sulfite and the
catalyst [RuCp*(CH3CN)3]PF6 in D2O at 50 °C. The reaction results in a production of [1-13C]disodium fumarate, molecule II, with the two
protons in a singlet state. Application of the S2M pulse sequence
converts the singlet state into a state that is magnetic and hence
observable, molecule II*. (b) Illustration of an ideal
case where no ST mixing occurs; only the |S0⟩ state is populated. (c) A case where ST mixing occurs leading
to a leak of |S0⟩ state population
to the |T0⟩ state. (d) A case where
the ST mixing is negated by applying a purge pulse prior the S2M,
which distributes the population of the |T0⟩ state to |T+⟩ and |T–⟩ states. (e) S2M pulse sequence
converts the singlet order into observable hyperpolarized magnetization.
The optimal parameters for this molecular system are τ = 15.6
ms, n2 = 14, n1 = 7. (f) Predicted signal intensities for three different scenarios.The polarization that is generated on the target
molecules can
be attenuated by singlet–triplet (ST) mixing (sometimes called
ST leakage) .[43] The hydrogen molecules
can form intermediate hydride species with the catalyst metal center,
where the two hydrogen atoms take up inequivalent positions, such
that they experience a chemical shift difference at high field. If
the lifetime of this intermediate complex is long enough, there can
be a significant leakage from the H2 proton singlet state
(|S0⟩) to the central triplet state
(|T0⟩), which generally reduces
the resulting PHIP signals.[43−45] The S2M sequence converts both
the |S0⟩ and the |T0⟩ states to magnetization but with opposite phases.
The population of the |T0⟩ state
therefore reduces the resulting NMR signal, as illustrated
in Figure c. This
process sometimes gives rise to a partially negative line (PNL) in
the 1H NMR spectra.[46] It is
also known to occur in non-hydrogenative PHIP experiments and has
been noted to give rise to “spontaneous” polarization
on the target molecules,[47] although generally
ST mixing is undesirable.Two methods have been shown to suppress
ST mixing: spin locking
on the 1H hydride resonance during the chemical reaction[39,46,48−56] and applying a hard π/2 purge pulse to deplete the |T0⟩ state prior to the polarization transfer
step.[46,52,55−59] These two methods are illustrated in Figure d.As we show in the following, the
study of ST mixing is greatly
facilitated by microfluidic PHIP, since instabilities associated with
bubbling experiments are avoided. Additionally, since hydrogenative
PHIP relies on irreversible chemical reactions, the chemical kinetics
influence the observed spectra, and the sample under study would need
to be replaced upon the reaction reaching completion. This is a particular
issue if the samples are scarce or expensive due to isotopic enrichment.
Finally, since hyperpolarized nuclei are in a nonequilibrium state,
the NMR signals relax on a time scale of seconds to tens of seconds,
unique to each molecular species and nuclear spin site, which can
convolute the observed results. This is especially problematic if
the signals relax quickly compared to the time it takes for a shaken
tube to be placed in the NMR magnet or for bubbles to settle in solution.
Materials
and Methods
All experiments were performed in a 11.7 T magnet
using a Bruker
AVANCE III spectrometer system. The NMR experiments were performed
with a custom-built probe delivering 1H RF pulses of 125
kHz amplitude.[21]1H spectra
were collected with a 16 ppm spectral width and 8 k point density.Para-enriched hydrogen gas (gas purity 99.995%) was continuously
produced by a Bruker parahydrogen generator BPHG90, with a specified
parahydrogen content of 89%. All chemical compounds were purchased
from Sigma-Aldrich (United Kingdom) and were used as received. All
NMR experiments were performed using a precursor solution of 100 mM
[1-13C]disodium acetylenedicarboxylate, 6 mM [RuCp*(CH3CN)3]PF6 catalyst, and 200 mM sodium
sulfite dissolved in D2O at 50 °C. It is been reported
that sodium sulfite improves the selectivity of the trans hydrogenation
reaction, although the mechanism of its action is not yet known.[33,60]
Microfluidic
Device
The microfluidic device was made
from three layers of polycarbonate (PC) (Self Adhesive Supplies, United
Kingdom) with 0.25, 0.5, and 0.25 mm thicknesses for the top, middle,
and bottom layers, respectively. The layers were cut from PC sheets
by a LS3040 CO2 laser cutter (HPC Laser Ltd., United Kingdom)
and were thermally bonded together as described elsewhere.[61] A semipermeable polydimethylsiloxane (PDMS)
membrane of 1 mm thickness (Shielding Solutions, United Kingdom) was
placed over the top half of the chip to seal the chip and to allow
hydrogen diffusion from the gas channel to the liquid channel. Figure a shows that the
chip and the membrane were held together by 3D printed holders (ProtoLabs,
United Kingdom) that attach threaded connectors for 1/16 in. capillaries
(Cole-Parmer, United Kingdom) to the four access points on the chip
for gas and liquid inlets and outlets.
Figure 2
(a) Microfluidic chip assembly. (b) Schematic
diagram of the experimental
setup. (c) Transmission line probe with a heater indicated as the
shaded area. (d) Drawing of the microfluidic device aligned with the
stripline plane of the detector. The key areas of the drawing are
enlarged.
In the magnet, the device
was placed in a home-built transmission line probe as shown in Figure b. A heater was clamped
outside of the stripline planes to heat the sample chamber in the
microfluidic chip to 50 °C. This is indicated by the shaded area
in Figure c. The heated
area did not include the 3D printed holders so that the solution in
contact with the hydrogen gas was kept at lower temperature in order
to maximize the solubility of the hydrogen gas. The reaction products
were detected in a 2.5 μL sample chamber. The chamber of the
chip was aligned with the constrictions of the stripline detector
as shown in Figure d.[21](a) Microfluidic chip assembly. (b) Schematic
diagram of the experimental
setup. (c) Transmission line probe with a heater indicated as the
shaded area. (d) Drawing of the microfluidic device aligned with the
stripline plane of the detector. The key areas of the drawing are
enlarged.
Experimental Procedure
All experiments were performed
inside the high-field NMR spectrometer as shown in Figure b. Experiments were conducted
at 50 °C (at the sample chamber only) with the supply of hydrogen
gas set to a pressure of 5 bar and flow rate of 10 mL min–1, stabilized by a mass flow controller (Cole-Parmer,
United Kingdom) connected at the end of the line. The flow of the
precursor solution was controlled with a syringe pump (Cole-Parmer,
United Kingdom) located outside the spectrometer. The target flow
rate was set to 10 μL min–1. Under
these operating conditions, the NMR signal reached a steady-state
after 10 min.Proton singlet order in [1-13C]fumarate
was converted into observable magnetization using the singlet-to-magnetization
(S2M) pulse sequence shown in Figure e. Maximum efficiency was achieved using the following
parameters: τ = 15.6 ms, n2 = 14, n1 = 7. The repetition delay was set to 60 s.CW-S2M experiments were performed by applying continuous wave irradiation
for 20 s at 0.5 and 2 kHz, while changing the resonance offset from
20 to −20 ppm. θ-S2M experiments were performed by applying
a hard pulse of varying flip angle prior the S2M pulse sequence. This
was achieved by varying the pulse duration from 0 to 8 μs in
steps of 0.22 μs.The reference spectrum was obtained
using hydrogen in thermal equilibrium.
The 1H spectrum was obtained by applying a π/2
pulse and averaging over 400 scans with a recycle delay of 20 s.
Results and Discussion
Figure a depicts
a single-scan proton NMR spectrum obtained after application of the
S2M pulse sequence in a steady-state flow experiment with 89% para-enriched
H2. This can be compared to the 400-scan reference spectrum
obtained after application of a π/2 pulse using hydrogen in
thermal equilibrium (i.e., not para-enriched) in Figure b.
Figure 3
Steady state 1H NMR spectra of [1-13C]fumarate
sample flowing at 10 μL min–1 in a microfluidic
device. (a) Spectrum collected with the S2M pulse sequence with 89%
parahydrogen. The trace displays a hyperpolarized [1-13C]fumarate peak at 6.6 ppm. The presence of exchanging hydrogen species
is indicated at 4 ppm (o-H2). (b) Reference spectrum resulting
from a π/2 pulse with hydrogen in thermal equilibrium. Cp*,
catalyst methyl protons; PC, background signal from the polycarbonate
chip material.
Steady state 1H NMR spectra of [1-13C]fumarate
sample flowing at 10 μL min–1 in a microfluidic
device. (a) Spectrum collected with the S2M pulse sequence with 89%
parahydrogen. The trace displays a hyperpolarized [1-13C]fumarate peak at 6.6 ppm. The presence of exchanging hydrogen species
is indicated at 4 ppm (o-H2). (b) Reference spectrum resulting
from a π/2 pulse with hydrogen in thermal equilibrium. Cp*,
catalyst methyl protons; PC, background signal from the polycarbonate
chip material.The spectra contain a peak at
6.6 ppm that corresponds to the fumarate
protons Ha. From the ratio of the signal intensity in the
reference and hyperpolarized spectra, the 1H polarization
was estimated. Accounting for the difference in the number of scans,
the signal enhancement was calculated as 190 ± 10. At the field
of 11.7 T and temperature of 50 °C, this corresponds to 0.7 ±
0.1% 1H polarization. At 10 μL min–1 flow rate, the concentration of fumarate was 1.2 ± 0.5 mM,
which corresponds to 1.2 ± 0.5% yield. This was calculated by
comparing the intensity of the Cp* peak in the reference spectrum
to the intensity of the fumarate peak and accounting for the difference
in the number of protons.The hyperpolarized spectrum features
the aforementioned partially
negative line at 4 ppm labeled o-H2. The heavy metal catalyst
and dissolved molecular hydrogen form intermediate complexes where
the two hydrogen nuclei occupy chemically inequivalent positions.
At high magnetic field, this introduces a chemical shift difference
between the two protons, which causes singlet state population to
leak into the population of the central triplet state. In addition,
the chemical shift difference lifts the degeneracy of the two triplet
state transitions. In rapid exchange, this leads to a small partially
negative line in the dissolved H2 signal,[46,47,54,57] as displayed in the spectrum in Figure a.To suppress the effects of ST mixing,
we performed experiments
in which we applied continuous-wave (CW) irradiation to the sample
for 20 s prior to the application of S2M and signal acquisition. The
pulse sequence is shown in Figure a. The resulting integral of fumarate signal intensity
at 6.6 ppm is plotted as a function of CW offset frequency in Figure b. Experiments were
performed with two different CW amplitudes, corresponding to 0.5 kHz
and 2 kHz nutation frequency on protons shown as gray and black circles,
respectively.
Figure 4
(a) Singlet-to-magnetization pulse sequence with spin-locking
field
applied during recycle delay. (b) Integral of signal intensity of
the hyperpolarized protons of [1-13C]disodium fumarate
as a function of the resonance offset of the spin-locking field. Experiments
were preformed with two CW amplitudes, corresponding to 2 kHz and
0.5 kHz nutation frequency shown as black and gray data points, respectively.
The signal amplitude was normalized to the signal acquired with CW
frequency set to 20 ppm.
(a) Singlet-to-magnetization pulse sequence with spin-locking
field
applied during recycle delay. (b) Integral of signal intensity of
the hyperpolarized protons of [1-13C]disodium fumarate
as a function of the resonance offset of the spin-locking field. Experiments
were preformed with two CW amplitudes, corresponding to 2 kHz and
0.5 kHz nutation frequency shown as black and gray data points, respectively.
The signal amplitude was normalized to the signal acquired with CW
frequency set to 20 ppm.The profiles of signal
intensity against the CW irradiation frequency
display a peak at around −11 ppm. This is a typical chemical
shift of hydride species for ruthenium complexes,[62] indicating that ST mixing does indeed occur for the hydride
species and is suppressed by CW irradiation. The 1H
spectra can be used to observe ST mixing, and this has been shown
in the case of SABRE by either applying a single hard pulse after
CW irradiation or a pulse sequence designed to probe higher spin-order
if hydride species undergo very fast chemical exchange.[46,47] In the present case, hydride species are not directly observable
due to fast exchange and low sensitivity. The signal is enhanced by
a factor of ∼3 when the spin-locking amplitude is set to either
to 0.5 kHz or 2 kHz applied at −11 ppm. The peak width in each
case corresponds roughly to the excitation bandwidth, resulting in
a narrower peak at the lower CW amplitude.We contrast this
with another method, which has been used to address
ST mixing effects: applying a hard pulse (which we will refer to as
the purge pulse) to the protons prior to polarization transfer and
signal acquisition. Application of a π/2 purge pulse on the
proton channel depletes the |T0⟩
state, which partially reconstitutes the population difference between
the |S0⟩ and |T0⟩ states.[46,52,55,57−59]Figure a shows
the pulse sequence used to investigate the phenomenon, and Figure b shows the hyperpolarized
Ha proton signals obtained experimentally by varying the
flip angle θ from 0° to 360° in steps of 10°.
The signal shows an oscillatory dependence on the flip angle of the
purge pulse, with maxima occurring at 90° and 270° and no
improvement seen near 180°. The signal at 270° is about
15% less than at 90°. While this is likely due to B1 inhomogeneities, other factors, for example, chemical
kinetics on the time scale of the pulse length, may also contribute.
Figure 5
(a) θ-S2M
pulse sequence. The θ angle was arrayed from
0° to 360° in steps of 10°. τ = 15.6 ms, n1 = 7, n2 = 14.
(b) Experimentally obtained Ha signals of [1-13C]fumarate as a function of the purge pulse angle. The y-axis shows the improvement of the signal intensity normalized to
the S2M signal without the purge pulse. (c) Computational simulation
of the spin system using SpinDynamica software.[63] (d) Comparison of the signal intensity of fumarate protons
(Ha) between the reference spectrum, pure S2M and 90°-S2M.
(a) θ-S2M
pulse sequence. The θ angle was arrayed from
0° to 360° in steps of 10°. τ = 15.6 ms, n1 = 7, n2 = 14.
(b) Experimentally obtained Ha signals of [1-13C]fumarate as a function of the purge pulse angle. The y-axis shows the improvement of the signal intensity normalized to
the S2M signal without the purge pulse. (c) Computational simulation
of the spin system using SpinDynamica software.[63] (d) Comparison of the signal intensity of fumarate protons
(Ha) between the reference spectrum, pure S2M and 90°-S2M.The spectral peaks in Figure b also display phase distortions depending
on the flip
angle of the purge pulse. The origin of the effect was confirmed by
numerical simulations using software package SpinDynamica,[63] and the result is shown in Figure c. The simulation assumes that
before the application of the sequence depicted in Figure a, the |S0⟩ and |T0⟩ states
are 55% and 45% populated, respectively. The populations of the other
triplet states are neglected. The agreement between experimental data
and numerical simulation is striking. Both experiments and simulations
show phase distortions when the flip angle is not an integer multiple
of 90°. These phase distortions arise as follows: When the first
pulse has a flip angle of 90°, the pulse transfers the population
of the central triplet state |T0⟩
to the outer triplet states |T±1⟩,
increasing the population difference between the singlet state |S0⟩ and the central triplet state |T0⟩ and hence enhancing the hyperpolarized
NMR signal at the end of the pulse sequence. However, the flip angle
of the first pulse is not a multiple of 90°, the transport of
populations between the triplet state is accompanied by the excitation
of single-quantum triplet–triplet coherences, of the form |T±1⟩⟨T0| and |T0⟩⟨T±1|. These coherences persist throughout
the pulse sequence and appear as out-of-phase signal components in
the observed spectrum, which have the effect of an undesirable phase
shift of the observed peak.In Figure d, a
comparison is shown between the reference spectrum obtained with 400
scans and single scan NMR spectra of Ha protons after
applying the S2M sequence with a purge pulse of 0° and 90°.
The enhancement in the latter case was calculated to be 1100 ±
10 in contrast to 190 ± 10 without applying the purge pulse.
This corresponds to 4.0 ± 0.1% 1H polarization and
hence a nearly 6-fold improvement in achievable fumarate signal. The
enhancement factor was calculated by comparing the integral of the
Ha peak in the hyperpolarized and reference spectrum, accounting
for the difference in the number of scans between the two spectra.The hard-pulse method yielded a 6-fold improvement in the achievable
fumarate signal, compared to 3-fold for the spin-locking method. This
was unexpected since the spin-locking method can in principle lead
to higher signal enhancements as it should mitigate the effect of
ST mixing entirely. We believe the lower efficiency provided by spin
locking is due to the micro-NMR probe design where the RF field is
concentrated exclusively onto the sample chamber as shown in Figure d. Therefore, the
solution outside the sample chamber is not affected by the RF irradiation,
and thus the ST mixing cannot be suppressed for molecules of fumarate
that formed in the channels before reaching the sample chamber. This
is not a problem for the hard-pulse method since the pulse is applied
after the chemical reaction.The results obtained show the remarkable
reproducibility and stability
of the chemical reactions performed in the microfluidic device over
the course of hours. A steady-state between the rate of chemical reaction
to form the hyperpolarized product and the rate of relaxation was
established, and without the confounding influence of these external
factors it is possible to study and optimize pulse sequences in hyperpolarized
NMR experiments. An additional benefit of working on a microfluidic
scale is the small sample volumes required, meaning expensive or scarce
samples can be more readily used. For example, the data in Figure b required 40 min
of experimental time, consuming 400 μL of solution, which is
the approximate volume required for a single PHIP experiment in a
conventional 5 mm NMR tube.The yield of fumarate in the chip
was 1.2 ± 0.5%. The low
yield of the reaction is most likely due to the limited uptake of
hydrogen into the flowing solution. Finite element simulations of
the chip have shown that when methanol is flowed through the chip
at 10 μL min–1 at a pressure of 5
bar, only 10 mM of hydrogen dissolves in the fluid.[64] Since in this work water was used as the solvent, the concentration
of hydrogen dissolved is expected to be lower due to poorer solubility
of hydrogen in water. Modifications to the apparatus to improve the
H2 uptake and yield of the reaction are currently underway.
Conclusion
In this work we employed a microfluidic chip to run PHIP reactions,
incorporating the hydrogenation, sample transport, RF excitation,
and signal detection steps onto a single device. In the reaction,
we hyperpolarized [1-13C]fumarate and used the S2M pulse
sequence to generate in-phase proton magnetization for observation
in the 2.5 μL sample chamber, achieving 4% proton polarization.
We used this system to investigate pulsed NMR methods that reduce
the detrimental effects of singlet–triplet mixing in this PHIP
reaction. We showed that application of continuous wave irradiation
prior to applying the S2M pulse sequence leads to a 3-fold improvement
to the fumarate proton polarization and also allowed us to locate
the chemical shift of the catalyst complex on which singlet–triplet
mixing occurs. We contrasted that with application of a π/2
pulse prior to applying the S2M sequence, which led to a 6-fold improvement
to the proton polarization.Continuous-flow PHIP approach allows
one to establish a constant
stream of a hyperpolarized product, providing stable and reproducible
conditions for the study of complex chemical and spin-dynamical phenomena
in a well-controlled environment. This is an important step toward
observation of metabolism in biological systems by hyperpolarized
NMR on a single microfluidic device. By bringing hydrogen gas into
solution through a membrane as opposed to bubbling or shaking, the
chemical reaction is more stable and reaches a steady-state with a
variation in the concentration of reaction product of 1%. By operating
at a small volume-scale (microliters), the consumption of expensive
materials is significantly reduced as compared to performing reactions
in NMR tubes.Not only does microfluidic implementation aid
in the development
of hyperpolarized NMR methods, but incorporating hyperpolarization
to enhance NMR signals opens the door to the use of NMR as a detection
method to study biological systems in microfluidic devices. Methods
such as fluorescence spectroscopy require using specific fluorescent
tags to track molecules, and UV–visible spectroscopy offers
a limited ability to identify molecules. The molecular specificity
and nondestructive nature of NMR spectroscopy makes it an ideal technique
to track metabolic reactions, and direct production of hyperpolarized
fumarate in a microfluidic chip is an important step toward this goal.
However, further developments are required to make this dream a reality,
such as the removal of toxic chemicals after the hyperpolarization
process and the incorporation of 13C NMR for background-free
detection with high chemical specificity and resolution.Much
work with hyperpolarized biomolecules relies on 13C
hyperpolarization and detection, since this is preferable
for in vivo imaging as the large background signals
from water molecules are not present. The probe used for this work
is doubly tuned for 1H and 13C
excitation and detection, but in order to perform such experiments,
several issues need to be addressed. A prerequisite of using PHIP-polarized
metabolites for biological studies is the ability to remove the catalyst
and reaction side-products from the solution. This has been shown
to be possible for [1-13C]fumarate via a precipitation
procedure[32] and for a variety of other
PHIP-polarized metabolites via the side arm hydrogenation procedure.[55] Precipitation procedures are not feasible in
microfluidic devices as the solid would block the fluidic channels.
However, scavenger compounds that bind the catalyst could potentially
be used for this purpose.[65,66]
Authors: Stephan Berner; Andreas B Schmidt; Mirko Zimmermann; Andrey N Pravdivtsev; Stefan Glöggler; Jürgen Hennig; Dominik von Elverfeldt; Jan-Bernd Hövener Journal: ChemistryOpen Date: 2019-06-04 Impact factor: 2.911