Literature DB >> 3513702

Evaluation of carriers used in the test methods of the Association of Official Analytical Chemists.

J M Ascenzi, R J Ezzell, T M Wendt.   

Abstract

Revision of the official test method for the determination of the tuberculocidal activity of disinfectants is being undertaken. The current procedure lacks precision and accuracy and is not quantitative. Variability associated with carriers and the lack of temperature control were evaluated in this paper. The use of porcelain versus stainless steel carriers was also evaluated. When carriers of either type were contaminated with Mycobacterium bovis BCG, the number of organisms on the carriers varied by as much as 1.0 on the log10 scale. The average number of organisms attached to each porcelain carried was 1.10 x 10(5) CFU (range, 2.7 x 10(4) to 2.7 x 10(5) CFU), whereas the average number of organisms attached to each stainless steel carrier was 1.38 x 10(5) CFU (range, 2.9 x 10(4) to 4.0 x 10(5) CFU). The average number of cells attached to the carrier was directly proportional to the number of cells in the contaminating cell suspension. Variations in drying time did not alter the number of cells attached to the carrier. When porcelain carriers were placed in a test solution, the average number of organisms washed from the carriers was 55% of the total, with a range of 19 to 80%, whereas for stainless steel carriers, the average number was 82% of the total, with a range of 52 to 96%. Data for B. subtilis spores were similar to those for M. bovis BCG, suggesting that there may be similar problems with the Association of Official Analytical Chemists sporicidal test, which uses carriers. It was also found that the lack of an exacting temperature control could influence the outcome of the test. Changes in temperature as little as 1 degree C could influence the rate of killing of M. bovis BCG.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3513702      PMCID: PMC238821          DOI: 10.1128/aem.51.1.91-94.1986

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  6 in total

1.  Use of membrane filters for measurement of mycobactericidal activity of alkaline glutaraldehyde solution.

Authors:  F M Collins
Journal:  Appl Environ Microbiol       Date:  1987-04       Impact factor: 4.792

2.  Effect of methodology, dilution, and exposure time on the tuberculocidal activity of glutaraldehyde-based disinfectants.

Authors:  E C Cole; W A Rutala; L Nessen; N S Wannamaker; D J Weber
Journal:  Appl Environ Microbiol       Date:  1990-06       Impact factor: 4.792

3.  Comparative mycobactericidal efficacy of chemical disinfectants in suspension and carrier tests.

Authors:  M Best; S A Sattar; V S Springthorpe; M E Kennedy
Journal:  Appl Environ Microbiol       Date:  1988-11       Impact factor: 4.792

4.  A more accurate method for measurement of tuberculocidal activity of disinfectants.

Authors:  J M Ascenzi; R J Ezzell; T M Wendt
Journal:  Appl Environ Microbiol       Date:  1987-09       Impact factor: 4.792

5.  A suspension method to determine reuse life of chemical disinfectants during clinical use.

Authors:  R A Robison; H L Bodily; D F Robinson; R P Christensen
Journal:  Appl Environ Microbiol       Date:  1988-01       Impact factor: 4.792

6.  Culture variability associated with the U.S. Environmental Protection Agency Tuberculocidal Activity Test Method.

Authors:  R A Robison; R J Osguthorpe; S J Carroll; R W Leavitt; G B Schaalje; J M Ascenzi
Journal:  Appl Environ Microbiol       Date:  1996-08       Impact factor: 4.792

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.