Literature DB >> 35133514

Features of hardware implementation of quasi-continuous observation devices with discrete receivers.

Oleksandr Maryliv1, Mykhailo Slonov2.   

Abstract

This article proposes an approach to the formalization of tasks and conditions for the hardware implementation of quasi-continuous observation devices with discrete receivers in remote sensing systems. Observation devices with a matrix are used in medicine, ecology, aerospace photography, and geodesy, among other fields. In the discrete receivers, the sampling of an image in the matrix receiver into pixels leads to a decrease in the spatial information of the object. In a greater extent, these disadvantages can be avoided by using photosensitive matrix with a regularly changing (controlled) density of elementary receivers-matrix (RCDOER-matrix). Currently, there is no substantiation of the tasks and conditions for the hardware implementation of RCDOER-matrix. The algorithmic formation of a quasi-continuous image of observation devices with the RCDOER-matrix is proposed. The algorithm used a formal pixel-by-pixel description of the signals in the image. This algorithm formalizes the requirements for creating a photosensitive RCDOER-matrix of a certain size, as well as for changing the mechanism for forming and saving a frame with observation results. The application of the developed method will allow multiplying the pixel size of the image relative to the pixel size of the RCDOER-matrix. Developed algorithms for RCDOER-matrix are supplemented by formalizing the tasks that arise when creating prototypes. In addition, the conditions for hardware implementation are proposed, which ensure the completeness of registration of the observation picture, and allow avoiding excessive pixel measurements. Thus, the results of the research carried out approximate the practical application of RCDOER-matrix.
© 2022. The Author(s).

Entities:  

Keywords:  Conditions of hardware implementation; Discrete receivers; Formalization of tasks

Year:  2022        PMID: 35133514      PMCID: PMC8825919          DOI: 10.1186/s42492-022-00102-7

Source DB:  PubMed          Journal:  Vis Comput Ind Biomed Art        ISSN: 2524-4442


  2 in total

1.  Efficient object location determination and error analysis based on barycentric coordinates.

Authors:  Andrea Bodonyi; Roland Kunkli
Journal:  Vis Comput Ind Biomed Art       Date:  2020-07-31

2.  Automatic quantification of superficial foveal avascular zone in optical coherence tomography angiography implemented with deep learning.

Authors:  Menglin Guo; Mei Zhao; Allen M Y Cheong; Houjiao Dai; Andrew K C Lam; Yongjin Zhou
Journal:  Vis Comput Ind Biomed Art       Date:  2019-12-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.