| Literature DB >> 35128361 |
Yue Wang1,2, Yu Zhao1, Yuan Ge1, Jin Cen2, Yun Liao1, Gufeng Xu1,3.
Abstract
BACKGROUND: Intrauterine adhesions (IUA) develop in up to 20% of women with a history of abortion. After hysteroscopic adhesiolysis, balloon stents are usually placed for seven days to prevent recurrence. The efficacy of prolonged use (30 days) of balloon stents has not been determined.Entities:
Keywords: balloon; hysteroscopic adhesiolysis; intrauterine adhesions; intrauterine contraception device; microbiota
Year: 2022 PMID: 35128361 PMCID: PMC8808160 DOI: 10.1016/j.eclinm.2021.101200
Source DB: PubMed Journal: EClinicalMedicine ISSN: 2589-5370
Figure 1Study flow chart (A) and images of the balloon (B) and IUD (C). IUD, intrauterine device; ITT, intention to treat; PPS, per protocol set.
A comparison of the baseline characteristics in the two groups.
| Age (years) | 30·5±5·1 | 30·0±4·20 | 0·58 |
| BMI (kg/m2) | 21·1±2·7 | 21·5±2·6 | 0·49 |
| Gravidity | 0·62 | ||
| 1 | 10 (22·7%) | 14 (29·8%) | |
| 2 | 16 (36·4%) | 18 (38·3%) | |
| ≥3 | 18 (40·9%) | 15 (31·9%) | |
| Parity | 0·86 | ||
| 0 | 25 (56·8%) | 26 (55·3%) | |
| 1 | 18 (40·9%) | 19 (40·4%) | |
| 2 | 1 (2·2%) | 2 (4·3%) | |
| Previous contraception | 0·26 | ||
| No birth control | 15 (34·1%) | 11 (23·4%) | |
| Condom | 29 (65·9%) | 36 (73·6%) | |
| Menstrual pattern | 0·45 | ||
| Normal | 5 (11·4%) | 8 (17·0%) | |
| Hypomenorrhea | 39 (88·6%) | 38(80·9%) | |
| Amenorrhea | 0 (0%) | 1 (2·1%) | |
| Peri-ovulatory endometrium thickness (mm) | 5·7±2·2 | 6·4±2·0 | 0·13 |
Data were mean± standard deviation or number (percentage%). Variables were compared using Student t-test or Mann-Whitney U test, as appropriate.
IUD, intrauterine device.
The recurrence, AFS intrauterine adhesion scores and new endometritis at the two consecutive hysteroscopies.
| Adhesion classification at first-look hysteroscopy | 0·23 | ||
| Moderate | 33 (75·0%) | 40 (85·1%) | |
| Severe | 11 (25·0%) | 7 (14·9%) | |
| Mean AFS scores at first-look hysteroscopy | 8·0 ±1·4 | 7·7±1·4 | 0·28 |
| Adhesion classification at second-look hysteroscopy | 0·76 | ||
| No adhesion | 22 (50·0%) | 21 (44·7%) | |
| Moderate | 16 (36·4%) | 17 (36·2%) | |
| Severe | 6 (13·6%) | 9 (19·1%) | |
| Mean AFS scores at second-look hysteroscopy | 1·8±2·0 | 2·0±2·0 | 0·53 |
| Reductions in AFS scores from first-look to second-look hysteroscopy | 6·3±2·5 | 5·6±2·1 | 0·22 |
| Recurrence rate at second-look hysteroscopy | 22 (50·0%) | 26 (55·3%) | 0·61 |
| New chronic endometritis at second-look hysteroscopy (%) | 5 (12·2%) | 11 (25·5%) | 0·11 |
Data were mean± standard deviation or number (percentage). Variables were compared using Student t-test.
AFS, American Fertility Society. IUD, intrauterine device.
Reproductive outcomes following treatment with balloon or IUD.
| n (%) | |||
| Ongoing pregnancy | 22 (56·4%) | 20 (57·1%) | 0·98 (0·66 -1·47) |
| Miscarriage | 4 (10·3%) | 8 (22·9%) | 0·45 (0·66 - 1·36) |
RR, relative risk.
, IUD as the reference group.
IUD, intrauterine device.
Figure 2Impact of balloon and IUD on the uterine and vaginal microbiota.
Panel A and B shows the quantitative comparisons of the bacterial DNA between the first-look and second-look hysteroscopic surgeries for uterine microbiota and for vaginal microbiota, respectively. The Y-axis represents the DNA quantity (ng) per ul of the 16s rRNA PCR amplicon. Panel C and D shows the comparisons of the uterine and vaginal microbiota between the first- and second-look hysteroscopic surgeries, and between the balloon and IUD groups, respectively. Analysis of alpha-diversity includes Shannon and ACE indices. Analysis of beta-diversity was performed by PCoA. In panel C, red dots on the PCoA plots represent samples collected at the first-look hysteroscopy, whereas blue dots represent those collected at the second-look hysteroscopy. In panel D, red dots represent samples from the balloon group, and blue dots represent those from the IUD group. For the box plots, the central lines within the box indicate the median, the boxes indicat the 1st and 3rd quartiles, and the whiskers indicate the minimum and maximum. The numbers 1 and 2 represent the first- and second-look hysteroscopies. The symbols B and I represent the balloon and IUD groups. NS, not significant; ⁎⁎⁎, p<0.001, ⁎⁎, p<0.01.