Wet coal beneficiation in Colombia is prohibitive due to the high cost and scarcity of commonly used dense media. The practical value of this study is that it demonstrates for the first time that a common fertilizer, calcium nitrate, can be used in the beneficiation of low-grade Colombian coals. Three high-ash low-grade Colombian coals (Valle, Cundinamarca, and Antioquia) commonly used in Colombian sugar mill stoker furnaces were tested. Coal mineralogy and prevalence were analyzed before and after washing using mineral liberation analysis. The swelling potential of the coals was assessed using a novel application of thermal mechanical analysis (TMA) and an ash fusion oven (AFO). Calcium nitrate reduced ash levels across all size fractions, even for high-ash coals like Valle (29% to below 7%) to acceptable levels for coke manufacturing or pulverized fuel combustion. The novel use of TMA and AFO to analyze coal swelling demonstrated that swelling varies under constrained and unconstrained conditions and the small sample size allows for rapid testing of coal swelling. This study has demonstrated that the use of common fertilizers can allow beneficiation to become a processing option for low-grade coals in Official Development Assistance countries where conventional dense media is prohibitively expensive.
Wet coal beneficiation in Colombia is prohibitive due to the high cost and scarcity of commonly used dense media. The practical value of this study is that it demonstrates for the first time that a common fertilizer, calcium nitrate, can be used in the beneficiation of low-grade Colombian coals. Three high-ash low-grade Colombian coals (Valle, Cundinamarca, and Antioquia) commonly used in Colombian sugar mill stoker furnaces were tested. Coal mineralogy and prevalence were analyzed before and after washing using mineral liberation analysis. The swelling potential of the coals was assessed using a novel application of thermal mechanical analysis (TMA) and an ash fusion oven (AFO). Calcium nitrate reduced ash levels across all size fractions, even for high-ash coals like Valle (29% to below 7%) to acceptable levels for coke manufacturing or pulverized fuel combustion. The novel use of TMA and AFO to analyze coal swelling demonstrated that swelling varies under constrained and unconstrained conditions and the small sample size allows for rapid testing of coal swelling. This study has demonstrated that the use of common fertilizers can allow beneficiation to become a processing option for low-grade coals in Official Development Assistance countries where conventional dense media is prohibitively expensive.
Colombia
is the fourth largest exporter of thermal coals and has
substantial coal reserves.[1] The majority
of Colombian coal is considered to be high-quality coal for power
generation.[2] Colombia also has large deposits
of high-ash coal,[3] which are predominantly
found in the South-Western region and commonly used in Colombian sugar
mill stoker furnaces. Colombian sugar mill stoker furnaces produce
steam for sugar production and also progressively more for energy
production to meet Colombia’s increasing electricity demand.[4] However, incomplete combustion issues have been
experienced with domestic Colombian coals. The higher heating value
(HHV) and coal utilization efficiency of these low-quality coals could
be improved via coal beneficiation due to their high ash content.[5] This is of particular benefit for coals, which
could then be used a metallurgical or coking coals, as they are categorized
as a critical raw material in the EU[6] and
have a higher economic value than thermal coals.[7−9] Despite this,
in Official Development Assistance (ODA) recipient countries such
as Colombia, coal beneficiation is limited by the availability of
chemicals for density separation and the cost of such processes.[10] Thus, there is a need for low-cost and sustainable
upgrading techniques that use more readily available separation chemicals
in ODA countries.There are two types of coal beneficiation:
wet and dry.[11] These methods are based
on differences in physical
and chemical properties between organic and mineral matter, such as
specific density, hydrophobicity, and particle size.[12] Wet beneficiation, particularly flotation, is the most
common method due to its high recovery rates and the quality of the
resultant product.[13,14] Froth flotation exploits the
differences in surface hydrophobicity of the different constituent
minerals to selectively separate the valuable minerals from gangue
by attaching them to air bubbles and recovering them from the mineral-laden
froth.[15] It has relatively low capital
costs and space requirements, as well as relatively high recovery
achievable under a wide range of operating conditions.[5] However, flotation uses large quantities of water and result
in the loss of millions of tons of coal in tailing ponds. It also
works most effectively for fine particle sizes (<600 μm),[16] which precludes its use on stoker furnace lump
coals, as they are in the 6–25 mm particle size range.[17] For lump coal, the wet method of dense medium
separation (DMS) is widely used.[18−21] DMS is regarded as a sink-and-float
process, which can remove undesirable impurities from run-of-mine
coal and upgrade the coal quality by simultaneously enabling lighter
minerals to float and denser minerals to sink.[22] After this separation, the dense medium is recovered via
evaporation and the beneficiated coal is cleaned by washing.[23] Commonly used dense media include organic solutions
(carbon tetrachloride (CCl4) and dichloromethane (CH2Cl2)[24]), magnetite suspension,[25−27] and salt solutions of zinc chloride (ZnCl2)[28] or sodium polytungstate.[29−31] Water-based
recovery methods are generally attractive from health, safety, and
environmental perspectives, as they use low-toxicity materials, and
be easily recovered from the coal and mineral matter particles.[23] While zinc chloride, chlorine salts, and magnetite
are the preferred mediums for coal DMS,[32−34] they are prohibitively
expensive to import into Colombia and have environmental and health
pollution issues.[1,35,36] Calcium nitrate, Ca(NO3)2, however, has a
similar density range to other separation mediums, with high solubility
(1290 g/L) in water. It is widely used as a fertilizer in Colombia,[37] with low environmental risk and similar cost
to magnetite at $280–310 per ton,[1,12,38] compared to $830 per ton (€720) for zinc chloride.[39] While calcium nitrate has been proposed as a
dense medium for fine coal beneficiation,[40−42] to date, only
calcium chloride solutions have been used on an industrial scale,[43] and there is no study on its use as a dense
media for the beneficiation of lump coal.The poor combustion
of coal can be related either to fuel or furnace
operational issues. When fuel-related, one of the key issues is oxygen
diffusion during combustion. For high-ash coals, this can be attributed
to ash film inhibition, particularly during the later stages of combustion,
as oxygen diffusion is limited by an ash film surrounding char particles.[44] Another consideration is how the coals behave
on the stoker furnace bed. Coking coals swell during combustion,[45] while lump thermal coals generally do not.[46] The swelling of lump coal is different from
that of small particles of coal. The deformation of fine coal particles
during pyrolysis takes place in all directions, while the swelling
trend of lump coal occurs along the laminated structure.[47] The swelling of coals has been analyzed via
image analysis and compared to the free swelling index (FSI) and found
that conventional methods of measuring swelling of small particles,
such as the FSI, cannot be used to predict the swelling of lump coal.[48]This paper explores the potential to upgrade
low-quality Colombian
coals commonly used in Colombian sugar mill stoker furnaces using
calcium nitrate DMS. The macro-scale swelling of the coals, before
and after beneficiation, was explored using two novel approaches,
thermomechanical analysis and an image-based method using an ash fusion
oven, to identify the potential of the coals to be upgraded for use
as higher-value coking coals.
Results and Discussion
Coal Characterization
The proximate
and elemental analysis of the three coals is detailed in Table , with their mercury,
higher heating value (HHV), and vitrinite reflectance are given in Table . Valle has the highest
ash content of all of the samples (29.6%), and Antioquia has the lowest
ash content (9.6%). The fixed carbon content of Valle is lower (38.8%)
than that of Antioquia (46.4%). Valle is a high-sulfur coal (>3%),
and coal washing has been shown to reduce sulfur content by 30–50%.[49] The high ash and sulfur contents of Valle make
it an ideal candidate for coal washing.
Table 1
Proximate
and Elemental Analyses of
As-Received Antioquia, Valle, and Mayagüez Coals
proximate
analysis (dry basis)
elemental
analysis (dry basis)
sample
inherent moisture
(%)
volatile matter (%)
fixed carbon (%)
ash (%)
total carbon (%)
hydrogen (%)
nitrogen (%)
sulfur (%)
oxygen (%)
Antioquia
8
49
40
11
67.3
3.7
1.4
0.9
13.4
Valle
1
30
41
29
53.9
4.1
1.0
3.6
7.5
Mayagüez
2
33
55
12
76
4.5
1.7
0.9
4.9
Table 2
Mercury, Higher Heating Value (HHV),
and Vitrinite Reflectance of As-Received Antioquia, Valle, and Mayagüez
Coals
sample
mercury (μg/kg)
HHV (MJ/kg)
vitrinite reflectance (%)
Antioquia
116
26.5
0.45
Valle
147
21.9
0.84
Mayagüez
106
30.1
0.78
All three
coals have mercury contents close to average values (Table ), which is 100 ±
10 μg/kg for bituminous, sub-bituminous, and lignite rank coals.[50] Mercury is considered to be a “coal-philic”
element with a strong affinity to inorganic and organic coal matter
as well as being authigenic in its origin. Furthermore, mercury tends
to concentrate in pyrite, and thus the removal of ash via coal washing
could be expected to result in lower mercury concentrations.[51,52] Based on the vitrinite reflectance levels (Table ), Antioquia is a sub-bituminous coal, and
Valle and Mayagüez fall into the bituminous coal rank.[53]Figure shows the coal used for the coal washing tests had particle
size in the range of 0–20 mm.
Figure 1
Particle size range vs cumulative passing
for the coals used in
the washing tests.
Particle size range vs cumulative passing
for the coals used in
the washing tests.
Coal
Washing
Ash Removal from the Coals
All
three coals were successfully demineralized using calcium nitrate
DMS (Table ). The
optimal dense medium was between 1.3 and 1.4 g/cm3 depending
on the coal. Valle showed the greatest reduction in ash content (76.7%),
which was not unexpected, given it had the highest initial ash content
(29.6%). Antioquia and Mayagüez had lower initial ash contents,
9.6 and 11.6%, respectively, and also showed significant ash reductions
via calcium nitrate DMS (35.1 and 55.6%, respectively). All coals
had ash contents below 7% after DMS, making them suitable as thermal
and metallurgical coals.[54,55]
Table 3
Yield and Ash Content for Gravity
Separation Tests of Antioquia, Cundinamarca, and Valle Coals
sample
medium density (g/cm3)
mass yield (% p/p)
ash in beneficiated fraction (% p/p)
ash in original
coal (% p/p)
ash reduction (%)
Mayagüez
1.30
49.2
5.1
11.55
55.6
Antioquia
1.40
51.1
6.2
9.56
35.1
Valle
1.35
48.9
6.9
29.62
76.7
Figure illustrates
how the ash content of the coals varies by particle size before and
after washing for particles below 4.75 mm. All three samples had lower
ash contents at the larger particle sizes compared to their finer
coal particles but greater percentage ash reduction for the finer
particle sizes. After washing, the ash content in the fine fractions
has dramatically reduced in most size fractions for Antioquia and
Mayagüez (Figure A,C), with ash contents in the 4.75 mm size fraction remaining at
similar levels to before DMS. Particles sink or float according to
their density relative to that of the liquid, but the rate of movement,
or their ambient velocity in the liquid, is the determining factor
in the separation process.[56] The most important
properties of a DMS process are the stability of the suspension (the
tendency for a solid phase to settle) and viscosity (resistance to
flow).[57] The lower final ash content of
the coarser fraction was potentially due to there being too much ash
in the finer fractions to separate effectively for the given process
conditions. The finer fractions had a greater percentage reduction
of ash relative to their initial ash content compared to the coarse
fractions. The ash content of the 4.75 mm size fraction was roughly
6–7% before DMS, indicating that DMS may only be effective
in removing ash to this level, and other treatments would be required
if a lower ash level was required. Valle exhibited reductions in ash
content in all size fractions (Figure B), and thus DMS is an effective method of ash removal
for high-ash coals.
Figure 2
Ash content by particle size for Antioquia and Antioquia
Beneficiated
(A), Valle and Valle Beneficiated (B), and Mayagüez and Mayagüez
Beneficiated (C). NB. AB = Antioquia, VB = Valle Beneficiated, AB
= Antioquia Beneficiated, Myz = Mayagüez, and MB = Mayagüez
Beneficiated.
Ash content by particle size for Antioquia and Antioquia
Beneficiated
(A), Valle and Valle Beneficiated (B), and Mayagüez and Mayagüez
Beneficiated (C). NB. AB = Antioquia, VB = Valle Beneficiated, AB
= Antioquia Beneficiated, Myz = Mayagüez, and MB = Mayagüez
Beneficiated.
Washed
Coal Analysis
Mineral liberation
analysis (MLA) was used to analyze the mineral quantity and location
in the as-received Valle (Figure A) and Antioquia (Figure A) coals; the washed float section for Valle
(Figure C), Antioquia
(Figure C), and Mayagüez
(Figure A); and the
washed residue for Valle (Figure B), Antioquia (Figure B), and Mayagüez (Figure B). The mineral quantities for these fractions
are given in Table .
Figure 3
Mineral liberation analysis (MLA) of as-received Valle <6 mm
(A), removed residue (B), and remaining coal (C).
Figure 4
Mineral
liberation analysis (MLA) of as-received Antioquia <6
mm (A), removed residue (B), and remaining coal (C).
Figure 5
Mineral liberation analysis (MLA) of Mayagüez remaining
coal (A) and removed residue (B).
Table 4
MLA Mineral Composition by Weight
Percentage of the As-Received, Washed Residue and Washed Float Coals
sample
Valle <6 mm (wt %)
Valle bottom (wt %)
Valle float (wt %)
Antioquia <6 mm (wt %)
Antioquia bottom (wt %)
Antioquia float (wt %)
Mayagüez bottom (wt %)
Mayagüez
float (wt %)
Coal
48.87
39.64
83.96
88.82
71.43
84.80
41.18
98.74
Pyrite
4.56
4.11
0.74
0.16
0.37
0.15
0.18
0.29
Vermiculite
0.03
0.40
0.00
0.00
0.09
0.01
0.01
0.00
Gypsum
0.22
1.34
0.18
0.06
0.19
0.18
0.03
0.01
Quartz
2.66
7.68
0.21
0.05
1.13
0.20
1.33
0.40
Kaolinite
0.07
1.98
0.02
0.15
0.73
0.09
0.79
0.01
Apatite
0.00
0.00
0.00
0.00
0.01
0.00
0.01
0.00
Zeolite Kaolinite
Mix
3.28
0.76
0.03
0.19
0.29
0.06
0.30
0.28
Kfe Clay Mix
34.98
25.42
0.86
4.94
8.70
2.70
14.37
0.19
Kaolinite-Coal Mix
2.89
15.46
14.00
5.40
12.54
11.36
41.14
0.03
Kaolinite Mix
2.43
3.19
0.01
0.19
3.19
0.43
0.67
0.03
Calcite
0.00
0.01
0.01
0.03
1.34
0.02
0.00
0.01
Mineral liberation analysis (MLA) of as-received Valle <6 mm
(A), removed residue (B), and remaining coal (C).Mineral
liberation analysis (MLA) of as-received Antioquia <6
mm (A), removed residue (B), and remaining coal (C).Mineral liberation analysis (MLA) of Mayagüez remaining
coal (A) and removed residue (B).The as-received Valle
coal shows the highest ash content of all
of the coals at 29.6% (Table and Figure ). The MLA of the as-received Valle coal shows that a wide range
of minerals is concentrated in large regions throughout the coal matrix
(Figure A). As the
coal fragments into smaller pieces, the minerals become increasingly
liberated. While it is clear that some minerals are intrinsically
linked to the coal particles, the large amounts of liberated minerals
in the finer fractions mean that mineral reduction and removal through
washing should be straightforward,[5] and
this is evidenced by the large reductions in ash content for the fine
size fractions of Valle during the DMS process (Figure B). Antioquia has a lower initial ash content
of 11% (Figure ),
and Figure A shows
that it is primarily formed of coal with small ribbons of finely dispersed
kaolinite in the coal matrix. However, there is one large piece of
iron-based clay with only a small amount of included coal, which demonstrates
that some minerals are still concentrated in large fragments within
the coal matrix. The Mayagüez as-received coal was not available
for MLA.
Figure 6
Proximate analysis of as-received Antioquia and Valle coal, and
Antioquia, Mayagüez, and Valle washed residue and float section.
Proximate analysis of as-received Antioquia and Valle coal, and
Antioquia, Mayagüez, and Valle washed residue and float section.Washing the coal significantly alters the proximate
(Figure ) and mineral
(Figures –5) composition of the coals. This change is most
notable for Valle,
which had a high starting dry ash concentration of 29%. Valle washed
residue has a dry ash content was 49%, while Valle float was less
than 7%. Valle’s dry fixed carbon increased from 41% in the
as-received coal to 59% in the washed float and 26% in the washed
residue. Antioquia’s dry ash reduced from 11% in the as-received
coal to 9% in the washed float, with 24% dry ash in the washed residue.
The fixed carbon increased from 40 to 49% in Antioquias washed float
section. Interestingly, Antioquia’s dry fixed carbon in the
washed residue remained at 40%. Mayagüez produced a washed
float with 5% dry ash and 25% dry ash in the washed residue. Mayagüez’s
dry fixed carbon content was the highest of all of the washed float
samples at 57%, with 45% dry fixed carbon in the washed residue.The calcium nitride DMS washing process not only dramatically reduces
the ash content of the coals but also influences which minerals remain
in the coal matrix. Large levels of minerals were removed from the
coal and left in the residue during the washing process, as illustrated
in Figures B, 4B, and 5B. The remaining
ash tends to be in the finer particles, and mainly constitutes of
the clay groups (Figures C, 4D, and 5A). This is notable in mineral concentrations in Table , with the iron clay mix remaining
at similar levels between the as-received coal and washed float but
significantly reduced in the washed residue for both Valle and Antioquia.
Most other minerals which were present in the as-received coal are
concentrated in the washed residue for Valle and Antioquia, with only
low levels remaining in the washed float.
Coal Swelling
The swelling potential
of coals is a key difference between thermal and metallurgical coals.[58] Bottom ash samples obtained from Colombian sugar
mills indicated that some of the low-grade domestic Colombian coals
used in Colombian stoker furnaces were swelling during combustion.
If ash content could be reduced to less than 10%, then potentially
these low-grade Colombian coals could be used as metallurgical coals,[54] and command a much higher price in the global
coal market.[8]Ash fusion ovens (AFO)
are usually used to investigate the slagging and fouling characteristics
of fuels,[59] but this study has identified
a novel use for AFO to analyze coal swelling. Lumps (<6 mm) of
Cundinamarca and Antioquia were placed in an AFO and heated to 900
°C in air and recorded using an externally mounted camera.[60]Video 1 shows the
coals swelling as they are heated up to 900 °C. Antioquia (right)
started to combust at 323 °C, as the top of the coal becomes
bright white. As the temperature increases, the bright white glow
progresses down the coal lump. At 370 °C, Cundinamarca (left),
violently erupts and the coal swells to 2–3 times its original
size. This violent eruption and swelling continue up to 420 °C
when Cundinamarca starts to collapse rapidly, with a total collapse
by 580 °C. Antioquia retains most of its original shape and continues
to glow until around 720 °C but only shows a minimal change in
shape at 900 °C.To investigate the swelling of the as-received
coals, small fragments
of Antioquia, Cundinamarca, and Valle were heated to 1000 °C
in the AFO, and 800 °C in a thermal mechanical analyzer (TMA).
Unfortunately, none of the as-received Mayagüez coal was available
for these tests. Figure compares the swelling behaviors from the TMA and AFO techniques.
Antioquia exhibited no swelling in either test, which matches the
behavior seen in Video 1. Cundinamarca
and Valle both exhibited swelling in the AFO and TMA tests. All samples
showed a height change at a lower temperature in the AFO compared
to the TMA.
Figure 7
Swelling of Antioquia (A), Cundinamarca (B), and Valle (C) in an
ash fusion oven (AFO) up to 1000 °C and via thermal mechanical
analysis (TMA) in air up to 800 °C.
Swelling of Antioquia (A), Cundinamarca (B), and Valle (C) in an
ash fusion oven (AFO) up to 1000 °C and via thermal mechanical
analysis (TMA) in air up to 800 °C.Antioquia was the only coal that did not visibly swell in the AFO.
The image analysis results show that it started to collapse at 310
°C in the AFO, while collapse did not commence until 400 °C
in the TMA (Figure A). In the AFO, Antioquia showed a gradual collapse between 300–450
°C to 60–70% of its original height up to 800 °C
and then collapsed to 25% of its original size by 1000 °C. In
the TMA, Antioquia showed a gradual collapse of around 80% of its
original size between 400 and 600 °C. At 600 °C, there was
a sudden collapse to 30% of its original size, finally decreasing
to 20% of its original size by 800 °C.Cundinamarca and
Valle both swelled before collapsing in both tests.
Both tests show the same profile for each coal, although the TMA has
more defined steps. For Cundinamarca (Figure B) in the AFO, swelling starts at 352 °C,
with a height increase of 29% at approximately 390 °C. Around
510 °C, the sample collapses to 66% of the original height, with
a final relative height of 53% at 1000 °C. In contrast, in the
TMA, Cundinamarca swelling begins around 390 °C. At roughly 430
°C, there is a sharp peak as the height increases to 55% above
its starting height. This is subsequently followed by a sharp collapse
to 19% of the original height at 636 °C, with the final relative
height of 18% at 800 °C. Valle exhibited similar temperature
expansion and collapse points for both methods (Figure C). The TMA shows a slightly delayed change
in height in comparison to the AFO, but when expansion or collapse
does occur, the steps are more defined and pronounced, with sharper
rises and falls, and clearer peaks. Furthermore, Valle had higher
peaks and lower final points than Cundinamarca and Antioquia.The results indicate that constrained coals (TMA) will have delayed
expansion compared to unconstrained coals (AFO). However, once expansion
and contraction start for the constrained coals, it will be more rapid
and explosive. This difference in coal swelling behavior of the AFO
and TMA is due to the differences in the experimental setup of the
two systems. In the AFO system, the particles are not constrained
and collapse under their weight. In the TMA system, the particles
are constrained under a force of 0.02 N as part of the macro-expansion
probe which measures the change in height. Thus, when the samples
collapse, the force pushes down the sample. Hence, the two systems
are modeling two different types of swelling; the AFO system models
unconstrained swelling, while the TMA system models constrained swelling.
Stoker furnaces are effectively packed beds that allow particles to
swell in both a constrained and unconstrained manner. Thus, the two
swelling methods provide useful and complementary data in understanding
material swelling in a packed bed, with applications beyond stoker
furnaces to other applications such as gasifiers.[61] Further work is required to understand how these tests
could be used in conjunction or as an alternative to the standard
free swelling index of coal test.[62]The swelling of the as-received coal, washed float section, and
washed residue section was compared in a TMA (Figure ). All coals show the same trend; if the
swelling was present in the as-received coal, then swelling occurred
in the washed float section, with minimal swelling in the washed residue
section. Swelling roughly occurs in the washed float and as-received
coal around the same temperature and peaks around the same temperature
for a given coal. However, there was a larger difference in the amount
of swelling observed. Valle washed float swelled by 132% above its
original height, while the Valle as-received coal swelled to 59% above
its original height. Both Valle as-received and washed float experienced
a dramatic collapse in height at around 650 °C. Valle as-received
coal reduced to 30% of its original height at 690 °C and reduced
to 16% for the washed float. In contrast, the Valle washed residue
swelled to 8% above its base height at 440 °C, and then gradually
dropped to 89% of its original height by 800 °C. The results
indicate that removing ash from high ash coal does not inhibit its
swelling potential, and thus could make it suitable for use as coking
coal.
Figure 8
Swelling of Valle (A) and Antioquia (B) as-received, washed float,
and washed residue coals, and Mayagüez washed float and residue
coal (C) in a TMA.
Swelling of Valle (A) and Antioquia (B) as-received, washed float,
and washed residue coals, and Mayagüez washed float and residue
coal (C) in a TMA.Mayagüez also
exhibited swelling in its washed float section
and minimal swelling in its washed residue (Figure B). The swelling started for the washed float
around 370 °C and peaked at 465 °C, with an increase of
69% above its original height. The coal then gradually reduced in
height to 29% above its base height at 620 °C, followed by a
sudden collapse to 8% around 700 °C. The washed residue experienced
a small amount of swelling, which peaked at 7% above its base height
at 420 °C. The coal then gradually reduced in height to 79% at
720 °C. Mayagüez washed residue then collapsed in height
to 22% at 730 °C, and then continually decreased to its final
height of 12% at 800 °C. Mayagüez washed residue contained
a lower level of ash (25%) than Valle (49%), and much higher carbon
(45% compared to 26%). Thus, the final collapse in Mayagüez
washed residue could be a result of the higher percentage of swelling
coal in the Mayagüez washed residue.Virtually no swelling
was observed in any of the Antioquia sections
(Figure C). Both the
washed float and residue sections had minimal swelling of 3% around
415 °C. Antioquia as-received coal gradually reduced in height
to 81% at 575 °C, but then experienced sudden collapse to 32%
at 600 °C. Both Antioquia washed float and residue experienced
this sudden collapse. This was most pronounced for the washed float,
which reduced from 83% of the base height at 620 °C to 34% at
630 °C. The washed float experienced a more gradual collapse,
from 89% of the base height at 605 °C to 70% at 660 °C,
with a final height of 56% at 800 °C.
Potential
of Calcium Nitrate DMS to Upgrade
Low-Grade Colombian Coals
This study has shown that calcium
nitrate DMS has the potential to upgrade low-grade Colombian coals.
Ash contents were reduced to below 7% in all of the coals, which represents
a 35–77% reduction in ash content. The washed coals ash content
is now within the standard for thermal coals used in pulverized fuel
boilers and for metallurgical coals used in coke making.[54,55] Stoker furnace coal particles are generally in the range of 6–25
mm,[17] and large-size (5–30 mm) coal
lumps are typically processed in wet dense medium cyclones.[63] Calcium nitrate is an attractive separation
medium for Colombia due to its widespread use as a low-cost fertilizer
and has been used successfully as a separation media in a dynamic
medium separation system for plastics separation.[64] For coal, calcium nitrate has been shown to improve coal
liquefaction for coal particles in the 63–250 μm range
in a dense medium cyclone,[41] and successfully
used at pilot scale using a hydro-cyclone and froth flotation.[40] Furthermore, it has been demonstrated that calcium
nitrate can be used to wash coal below 100 mesh (150 μm) in
a decanter centrifuge configuration at an industrial scale, but processing
costs were identified as an issue.[42] To
date, no studies in the literature have been presented for beneficiating
lump coal used in stoker furnaces. Thus, the next stage is to trial
its use in pilot-scale wet dense medium cyclones with the same coals.
This pilot-scale trial would provide sufficient data for a life cycle
assessment and life cycle costing to quantify the environmental and
economic benefits of using calcium nitrate DMS for the beneficiation
of low-grade Colombian lump coals. The study should also explore the
contamination and reuse of the process water used, as well as the
impact of pH and time on the process.Another consideration
for scale-up is the environmental issues concerning Calcium nitrate.
Exposure to Calcium nitrate can cause headaches, dizziness, nausea,
and vomiting,[65] and the excessive use of
nitrates has been linked to land and water toxicity concerns.[66] These concerns would need to be addressed in
the scale-up of the process. A future research avenue should be the
exploration of alternative calcium-based media instead of calcium
nitrate, such as shellfish shells and eggshells, as has been done
for microbial-induced carbonate precipitation,[67] or the potential to recover calcium nitrate from wastes,
such as lime-softening sludge.[68] Finally,
to maximize the valorization of the process, it will be necessary
to recycle the calcium carbonate. Calcium nitrate can be recovered
via organic solvents in the production of potassium, although it has
not been explored for a DMS system and should be an area of future
research.[69]The swelling of Valle
coal during combustion suggests that it is
potentially better suited for use as coking coal rather than thermal
coal.[54] This would significantly increase
its value and help make demineralization a more financially viable
prospect. To explore this potential further, washed Valle coal would
need to be characterized for its coking potential and tested in pilot-scale
coking ovens. In addition, novel coking methods, such as microwave
technology,[45] have demonstrated that noncoking
coals can be coked rapidly, which may facilitate low-grade coking
coal to be used in blends to produce high-quality cokes.
Conclusions
This study has for the first time demonstrated
that calcium nitrate
DMS can be used to beneficiate high-ash lump coals commonly used in
stoker furnaces. Thus, there is the potential for beneficiation using
low-cost fertilizers to become a processing option for low-grade coals
in ODA countries where conventional dense media is prohibitively expensive.
Calcium nitrate DMS reduced the ash content below 7% for all of the
coals. This was particularly notable for Valle, whose ash content
dramatically reduced across all size fractions from 29% to below 7%,
which is an acceptable level for coking coals (<10% ash). Further
investigation is required to analyze the potential for the washed
Valle coal to be used as metallurgical coal, as this would significantly
increase its economic value and the viability of scaling up the calcium
nitrate beneficiation process. Ash reduction to below 7% would also
enable the other coals to be suitable for other higher-value applications
such as pulverized fuel combustion.The novel use of TMA and
AFO to analyze coal swelling demonstrated
that swelling varies in constrained and unconstrained conditions.
The small sample size allows for rapid testing of coal swelling in
comparison to the standard free swelling index test. The expanded
use of both TMA and AFO in coal characterization has been identified
as an area for further research.
Materials
and Methods
Samples
This study analyzed three
Colombian coals commonly used in stoker furnaces in Colombian sugar
mills. Two were from distinct mining areas in Colombia: Antioquia,
and Valle, as well as a blend (Mayagüez), used at the Mayagüez
sugar mill in the Cauca Valley in Colombia. Basic coal characterization
and coal washing experiments were conducted at Universidad del Valle
in Cali, Colombia. Petrographic analysis was conducted at Servicio
Geológico Colombiano in Bogotá, Colombia, and all coal
swelling, MLA, and thermal characterization experiments were conducted
at the University of Nottingham, U.K. Unfortunately, none of the as-received
Mayagüez blend coal was available for the UK-based tests. To
add more samples for the TMA and AFO test, a surrogate was added to
replace the missing Mayagüez coal. This fourth sample was a
Colombian coal (also commonly used in Colombian sugar mills) called
Cundinamarca.
Coal Compositional Analysis
Coal
characterization was done by proximate (TGA), ultimate (CHNS), and
petrographic analyses. All analyses were conducted in duplicate with
a total error lower than 1%. Compositional analysis of the as-received
coals was carried out by the Laboratorio de combustión y combustibles
(Laboratory of combustion and fuels) in the Universidad del Valle,
Cali, and Servicio Geológico Colombiano in Bogota, Colombia.
Inherent moisture, volatile matter, and ash were determined using
registered weight loss in a thermogravimetric analyzer (LECO TGA-601).
Fixed carbon was determined by difference according to ASTM D3172.[70] Carbon, hydrogen, and nitrogen (CHN) determination
was obtained by combustion of 1 g of sample at 950 °C in an oxygen
atmosphere on a LECO TruSpec CHN according to ASTM D5373.[71] Total sulfur was determined using ASTM D4239
on a LECO S-144.[72] Oxygen was determined
by difference. High heating value (HHV) was obtained in a calorimeter
bomb LECO AC600 according to ASTM D5865.[73] Mercury content was determined in a Milestone DMA-80 mercury determination
system following ASTM D6722 procedure.[74] Vitrinite reflectance was measured in a microscope Olympus BX-51
with coupled J&M MSP 200 spectrophotometer, using the reflected
light, monochromatic polarized with an oil objective 50×, and
an overall magnification of 500×. Initially, the system was calibrated
using 5 reflectance standards. The mean reflectance was determined
using ICCP and ASTM D2798 procedures.[75] Granulometric distribution of the used coals in the beneficiation
separation was obtained using sieve analysis. The sieve sizes used
were 4.75, 2.36, 1.00, 0.42, 0.25, 0.125, 0.075, and 0.032 mm.The thermal composition of the as-received and washed samples was
analyzed using thermogravimetric analysis (TGA) at the University
of Nottingham. The analysis also provided accurate fixed carbon contents
of each sample. Thermal profiles were produced using TA Instruments
Q500 TGA (New Castle, DE). TGA tests used 10–15 mg of a sample
with a particle size range of 75–300 μm. The method and
analysis of the TGA profiles were based on the slow pyrolysis method
developed by Lester et al.[76] The sample
was heated in a furnace at 5 °C/min in 100 ml/min of Nitrogen
from atmospheric temperature to 900 °C, after which the gas was
switched to air at 100 mL/min. The composition of the samples is given
by moisture, dry volatile, fixed carbon, and dry ash contents following
BS ISO 17246:2010.[77]
Mineral Composition
Mineral liberation
analysis (MLA) was conducted at the University of Nottingham. MLA
provides detailed information on the association of minerals, as well
as the composition of single particles and particle populations exposed
on the cross-sectioned surface of a grain mount. The samples were
prepared in carnauba wax with an epoxy resin backing, ground using
800/1200/2400 grit silicon carbide paper, and polished with 6 μm
diamond solution. Polished blocks were coated with a 10 nm carbon
film using a Quorum Q150T Thin-Film Coater and MLA was conducted on
a Scanning Electron Microscope model FEI Quanta 600i SEM with energy-dispersive
X-ray.[78] The FEI MLA 3.1 software was used
to relate mineral content in the coal particle to its surface area.
Grain-based X-ray mapping (GXMAP) measurements combine X-ray mapping
with the XBSE image processing steps of back-scatter electron (BSE)
image acquisition, particulation, and segmentation before X-ray spectra
collection. Custom BSE gray value triggers and specific X-ray spectrum
triggers were defined for detailed X-ray mapping of coal grains of
interest. The X-ray spectra of each grain were used to identify the
individual mineral phases using the EDAX Genesis 4000 energy-dispersive
(EDS) software. The EDS classification involves matching collected
spectra to a spectra database. The surface area of the various classified
particles is computed to generate the wt % composition of minerals.
Coal Swelling Analysis
Thermal
Mechanical Analysis
The
swelling potential of Cundinamarca, Valle, and Antioquia coal was
tested using a TA Instruments Q400 Thermal Mechanical Analyzer (TMA)
at the University of Nottingham; 1 mm thick pieces of coal with flat
parallel surfaces were placed in the macro-expansion probe with a
constraining force of 0.02 N. The samples were heated to 800 °C
in air at a ramp rate of 10 °C/min, and the expansion and/or
contraction of the coal was measured using the TA Instruments Universal
Analysis software. The measurements were then converted into a percentage
change in height relative to the starting height of the sample.
Swelling in an Ash Fusion Oven
Coal swelling
was also measured for Cundinamarca, Valle, and Antioquia
coal in a Carbolite Gero Ash Fusibility Test Furnace–CAF G5
using the advanced ash fusion test developed by Daley et al.[60] at the University of Nottingham; 1 mm pieces
of coal with flat parallel surfaces were placed on Carbolite Gero
25 mm × 25 mm recrystallized alumina ceramic tiles and loaded
in the furnace. The furnace temperature was increased from 25 to 1000
°C at a rate of 7 °C/min under oxidizing conditions (airflow
rate of 4 L/min at 27.5 kPa (4 psi)). Images were taken every 1 °C
on an integrated HD 1.3 Mb camera with an image size of 1280 by 1024
pixels. MATLAB (version R2017b) was used to analyze each image and
measure the change in height of the sample. The measurements were
then converted into a percentage change in height relative to the
starting height of the sample.Coal washing was conducted
at the Universidad del Valle using DMS techniques. In preliminary
tests, the coal-dense medium pulp was prepared using 15% w/w with
different medium densities of calcium nitrate. For a medium density
of 1.3 g/cm3, all of the particles floated, whereas at
1.45 g/cm3 density, all particles sunk. DMS was carried
out using long plastic bags to observe the separation of particles
in the dense medium in the density range of 1.0–1.5 g/cm3. After 36 h, the concentrated organic and mineral matter
was located at the top and bottom of the medium, allowing both fractions
to be separated. Beneficiated coal from the top and concentrated mineral
matter from the bottom was washed with water to remove the solution
of calcium nitrate and then dried at room temperature. ASTM D3173[79] and D3174[80] were
used to evaluate the mass yield and organic recovery of the beneficiated
coal. Ash content was obtained via ASTM D3174 after sieving.
Authors: Christopher Hamann; Marina Spanka; Dirk Stolle; Gerhard Auer; Eric Weingart; Dominik Al-Sabbagh; Markus Ostermann; Christian Adam Journal: J Hazard Mater Date: 2020-07-17 Impact factor: 10.588
Authors: A P E Sueitt; T M Yamada-Ferraz; A F Oliveira; C M R Botta; P S Fadini; M R L Nascimento; B M Faria; A A Mozeto Journal: Ecotoxicol Environ Saf Date: 2015-04-09 Impact factor: 6.291
Authors: Orla Sioned Aine Williams; Patrick Daley; Joseph Perkins; Shoaib Shah; Edward Andres Garcia Saavedra; Maria Trujillo; Juan Barraza-Burgos; Carlos Julio Espitia; Maribel Barajas; Juan Sebastian Saltaren; Nicolás Javier Gil; Edward Henry Lester Journal: ACS Omega Date: 2022-04-02