| Literature DB >> 35127737 |
Jing Zhao1,2,3, Jiao Zhao4, Wen Yang5, Ling Sun1,2,3, Yishan Qian1,2,3, Xiaoying Wang1,2,3, Xingtao Zhou1,2,3.
Abstract
PURPOSE: To investigate the effects of ocular residual astigmatism (ORA) and target-induced astigmatism (TIA) on the efficacy of toric implantable collamer lens (TICL) with central hole for myopic astigmatism correction.Entities:
Keywords: corneal tomography; myopic astigmatism; ocular residual astigmatism; target-induced astigmatism; toric implantable collamer lens
Year: 2022 PMID: 35127737 PMCID: PMC8813979 DOI: 10.3389/fmed.2021.737358
Source DB: PubMed Journal: Front Med (Lausanne) ISSN: 2296-858X
Preoperative data stratified by ORA and TIA, respectively.
|
|
|
|
|
|
|
|
|
|
|
|
|
|---|---|---|---|---|---|---|---|---|---|---|---|
| Low ORA | 35/20 | 28.16 ± 4.19 (20–37) | −9.42 ± 2.47 (−15 to −4.75) | −2.07 ± 0.97 (−4 to −1) | −10.46 ± 2.52 (−16 to −5.5) | 0.02 ± 0.06 (−0.1 to 0.15) | 1.80 ± 0.71 (0.5–3.3) | 0.32 ± 0.10 (0.12–0.5) | 2.07 ± 0.97 (1–4) | 14.77 ± 2.61 (10–21) | 2,833.36 ± 316.02 (2,118–3,715) |
| High ORA | 38/35 | 28.59 ± 4.89 (19–38) | −8.93 ± 2.16 (−13.75 to −3.50) | −1.79 ± 0.78 (−4 to −1) | −9.84 ± 2.15 (−14.75 to −4.5) | 0.00 ± 0.07 (−0.1 to 0.15) | 1.88 ± 0.66 (0.3–3.4) | 0.85 ± 0.27 (0.53–2.03) | 1.79 ± 0.78 (1–4) | 15.15 ± 2.30 (11–20) | 2,789.81 ± 315.04 (2,085–3,798) |
| 0.71 | 0.62 | 0.25 | 0.09 | 0.15 | 0.27 | 0.49 | <0.001 | 0.09 | 0.39 | 0.46 | |
| Low TIA | 25/20 | 27.85 ± 5.2 (19–38) | −9.23 ± 2.34 (−15 to −4.75) | −1.15 ± 0.23 (−1.5 to −1) | −9.81 ± 2.34 (−15.75 to −5.5) | 0.00 ± 0.07 (−0.1 to 0.15) | 1.35 ± 0.45 (0.3–2.8) | 0.61 ± 0.35 (0.13–2.03) | 1.15 ± 0.23 (1–1.5) | 14.86 ± 2.24 (10–21) | 2,776.93 ± 270.55 (2,214–3,450) |
| High TIA | 39/34 | 28.84 ± 3.93 (22–37) | −9.10 ± 2.31 (−15 to −3.50) | −2.58 ± 0.67 (−4 to −2) | −10.39 ± 2.32 (−16 to −4.5) | 0.01 ± 0.07 (−0.1 to 0.15) | 2.25 ± 0.54 (1–3.4) | 0.60 ± 0.33 (0.12–1.36) | 2.58 ± 0.66 (2–4) | 15.07 ± 2.62 (10–20) | 2,838.11 ± 347.62 (2,085–3,798) |
| 0.821 | 0.25 | 0.76 | <0.001 | 0.18 | 0.69 | <0.001 | 0.94 | <0.001 | 0.64 | 0.30 |
F, female; M, male; SE, spherical equivalence; RA, refractive astigmatism by manifest refraction; CA, corneal astigmatism; ORA, ocular residual astigmatism; LogMAR, log minimum angle of resolution; CDVA, corrected distance visual acuity; IOP, intraocular rressure; ECD, endothelial cell density; TIA, target induced astigmatism (equal to refractive astigmatism by manifest refraction).
Figure 1Refractive outcomes in the low- and high- ocular residual astigmatism (ORA) groups. (A) Cumulative percentage of eyes attaining specified levels of uncorrected distance visual acuity (UDVA); (B) Postoperative vs. preoperative UDVA; (C) Change in corrected distance visual acuity (CDVA); (D) Target-induced astigmatism plotted vs. surgical-induced astigmatism at the last follow-up; (E) Distribution of postoperative spherical equivalent refraction; (F) Distribution of preoperative and postoperative astigmatism amplitudes.
Figure 2Refractive outcomes in the low- and high-target-induced astigmatism (TIA) groups. (A) Cumulative percentage of eyes attaining specified levels of UDVA; (B) Postoperative vs. preoperative UDVA; (C) Change in CDVA; (D) TIA plotted vs. surgical-induced astigmatism at the last follow-up; (E) Distribution of postoperative spherical equivalent refraction; (F) Distribution of preoperative and postoperative astigmatism amplitudes.
Postoperative comparison of low ORA group and high ORA group.
|
|
|
| |||||
|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
|
| |
| LogMar UDVA | −0.05 ± 0.07 | −0.07 ± 0.07 | −0.07 ± 0.07 | −0.08 ± 0.07 | 0.87 | 0.69 | 0.10 |
| LogMar CDVA | −0.07 ± 0.07 | −0.10 ± 0.07 | −0.10 ± 0.07 | −0.10 ± 0.07 | 0.24 | 0.01 | <0.001 |
| SE(D) | −0.08 ± 0.26 | −0.11 ± 0.24 | −0.04 ± 0.26 | −0.07 ± 0.22 | 0.43 | 0.08 | 0.85 |
| Cylinder diopter by MR(D) | −0.32 ± 0.18 | −0.26 ± 0.16 | −0.34 ± 0.20 | −0.28 ± 0.18 | 0.52 | 0.01 | 0.83 |
| CA(D) | 2.00 ± 0.73 | 1.97 ± 0.80 | 2.00 ± 0.72 | 1.95 ± 0.72 | 0.93 | 0.31 | 0.49 |
| Vault (μm) | 529.13 ± 191.91 | 524.18 ± 192.12 | 525.63 ± 148.53 | 518.57 ± 148.78 | 0.91 | <0.001 | 0.16 |
| IOP | 14.88 ± 2.50 | 14.75 ± 2.64 | 15.31 ± 2.24 | 15.23 ± 2.43 | 0.25 | 0.15 | 0.69 |
| Refractive SIA | 1.90 ± 0.99 | 1.98 ± 0.98 | 1.66 ± 0.85 | 1.67 ± 0.84 | 0.14 | 0.63 | 0.93 |
| Corneal SIA | 0.35 ± 0.25 | 0.31 ± 0.25 | 0.35 ± 0.20 | 0.35 ± 0.26 | 0.53 | 0.70 | 0.34 |
| CI | 0.89 ± 0.17 | 0.94 ± 0.14 | 0.90 ± 0.19 | 0.91 ± 0.14 | 0.76 | 0.38 | 0.22 |
| IOS | 0.19 ± 0.14 | 0.15 ± 0.10 | 0.22 ± 0.16 | 0.19 ± 0.15 | 0.19 | 0.02 | 0.94 |
ORA, ocular residual astigmatism; CDVA, corrected distance visual acuity; UDVA, uncorrected distance visual acuity; SE, spherical equivalence; MR, manifest refraction; SIA, surgical induced astigmatism; CA, corneal astigmatism; IOP, intraocular pressure; IOS, index of success; CI, correction index.
The low ORA group at post 1 month vs. the high ORA group at post 1 month;
the low ORA group at post 12 months vs. the high ORA group at post 12 months;
the low ORA group at post 1 month vs. the low ORA group at post 12 months;
the high ORA group at post 1 month vs. the high ORA group at post 12 months.
Stands for interaction between Group and Time.
Postoperative comparison of low and high TIA Group.
|
|
|
| |||||
|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
|
| |
| LogMarUDVA | −0.08 ± 0.07 | −0.09 ± 0.07 | −0.05 ± 0.06 | −0.05 ± 0.06 | 0.003 | 0.14 | 0.45 |
| LogMarCDVA | −0.11 ± 0.07 | −0.11 ± 0.07 | −0.09 ± 0.06 | −0.10 ± 0.06 | 0.12 | 0.11 | 0.11 |
| SE(D) | −0.05 ± 0.25 | −0.05 ± 0.22 | −0.05 ± 0.27 | −0.12 ± 0.23bd | 0.46 | 0.006 | 0.003 |
| Cylinder diopter by MR(D) | −0.31 ± 0.17 | −0.26 ± 0.15 | −0.36 ± 0.20 | −0.29 ± 0.19 | 0.21 | <0.001 | 0.30 |
| CA(D) | 1.49 ± 0.48 | 1.43 ± 0.47 | 2.43 ± 0.61 | 2.40 ± 0.66 | <0.001 | 0.02 | 0.40 |
| Vault (μm) | 538.41 ± 176.71 | 534.07 ± 176.59 | 517.86 ± 163.77 | 510.31 ± 164.13 | 0.48 | <0.001 | 0.48 |
| IOP | 15.08 ± 2.14 | 14.97 ± 2.39 | 15.14 ± 2.56 | 15.04 ± 2.66 | 0.89 | 0.26 | 0.93 |
| Refractive SIA | 1.00 ± 0.37 | 1.02 ± 0.35 | 2.42 ± 0.72 | 2.48 ± 0.68 | <0.001 | 0.025 | 0.38 |
| Corneal SIA | 0.30 ± 0.16 | 0.27 ± 0.21 | 0.39 ± 0.26 | 0.39 ± 0.28 | 0.004 | 0.42 | 0.62 |
| CI | 0.85 ± 0.23 | 0.88 ± 0.17 | 0.93 ± 0.10 | 0.96 ± 0.09 | 0.001 | 0.07 | 0.77 |
| IOS | 0.28 ± 0.18 | 0.23 ± 0.14 | 0.15 ± 0.10 | 0.12 ± 0.09 | <0.001 | <0.001 | 0.43 |
TIA, target induced astigmatism; CDVA, corrected distance visual acuity; UDVA, uncorrected distance visual acuity; SE, spherical equivalence; MR, manifest refraction; CA, corneal astigmatism; SIA, surgical induced astigmatism; IOP, intraocular pressure; IOS, index of success; CI, correction index.
The low TIA group at post 1 month vs. the high TIA group at post 1 month;
the low TIA group at post 12 months vs. the high TIA group at post 12 months;
the low TIA group at post 1 month vs. the low TIA group at post 12 months;
the high TIA group at post 1 month vs. the high TIA group at post 12 months. *Stands for interaction between Group and Time.
Figure 3Single-angle polar plots of refractive SIA in the low- and high-ORA groups. ORA, ocular residual astigmatism; SIA, surgical-induced astigmatism.
Figure 4Single-angle polar plots of refractive SIA in the low- and high-TIA groups. ORA, ocular residual astigmatism; SIA, surgical-induced astigmatism; TIA, target-induced astigmatism.