M Busto1, E E Tarifa2, M Cristaldi3, J M Badano1, C R Vera1. 1. Institute of Research On Catalysis and Petrochemistry, INCAPE, FIQ-UNL, CONICET, Collecting Ring, National Road 168 km 0, El Pozo, 3000 Santa Fe, Argentina. 2. Faculty of Engineering, Universidad Nacional de Jujuy, CONICET, Ítalo Palanca No. 10, 4600 San Salvador de Jujuy, Argentina. 3. Av. Gob. Gregores & Piloto Rivera, Universidad Nacional de La Patagonia Austral, 9400 Río Gallegos, Argentina.
During 2019–2021, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), a new virus of the coronavirus family, spread throughout the world causing the so-called coronavirus disease (COVID-19) pandemic with a terrible death toll. During this time, there was a big discussion over the possibilities of contagion through the air. It was evident that the virus was transported in the drops and aerosols generated by sick people coughing or sneezing, and that it remained after some time on hard surfaces. Frequent hand sanitization, mask wearing and social distancing were the main measures against the spread of the virus. However, it was not initially clear whether droplet nuclei or the virus itself could remain suspended in the air for long periods of time. Some researchers then first reported that if small drops containing the SARS-CoV-2 virus particles reached the size of an aerosol (lower than 5 microns), they could remain suspended in the air for 0.5–3 h (Kern and Krishnan 2006). Later, more evidence was gathered, and it was concluded that aerosols could represent an important transmission pathway for SARS-CoV-2 because of many reasons (Shelton-Davenport et al 2020): (1) aerosols can contain infectious SARS-CoV-2, be transported many meters from the emitter and remain suspended in air for hours; (2) asymptomatic individuals are a source of aerosols with main sizes < 10 µm and produce only a few droplets; (3) super-spreading events (events in which an infectious disease is spread much more than usual) can only be explained by aerosol transmission; (4) aerosols can lead to both close and long-range exposure if concentrated in a badly ventilated room.Therefore, the possibility of contagion through air, even not in the proximity of a person with the virus, is possible. It would also be higher in hospital rooms or ambulances. For these and other places with a high possibility of finding a high virus concentration, decontamination of the room air should be mandatory. In the case of filtering, the best known technology is the use of HEPA (High Efficiency Particulate Arresting) filters that have a collection efficiency of 99.95% for particles with a size higher than > 0.3 microns. Microorganisms may have quite different sizes depending on their origin. Generally speaking, fungal spores have 2–5 microns; bacteria, 0.3–10 microns; and viruses, 0.02–0.3 microns (3M 2020; Levin and Angert 2015; Matthews 1975; Popov et al 2019; Reponen et al 2001).Some reported sizes of microorganisms are detailed in Table 1.
Table 1
Reported sizes of some biologically hazardous microorganisms
Microorganism
Size (μm)
Ref
Microorganism
Size (μm)
Ref
Viruses
Bacteria
SARS-CoV-2
0.07–0.09
(Kim et al 2020)
Mycobacterium tuberculosis
1–5
(3M 2020)
Hepatitis B virus
0.042–0.047
(Feng et al 2020)
Bacillus anthracis
1.0–1.5
(3M 2020)
Human adenovirus 5
0.07–0.09
(3M 2020)
Clostridium Botulinum
0.9–1.2 (width)
4–6 (length)
(Boerema and Broda 2004)
Alpha, Beta and Gamma influenza virus
0.08–0.012
(3M 2020)
Fungal spores
Hepatitis A virus
0.028–0.030
(Kern and Krishnan 2006; Roberts et al 2010)
Batrachochytrium dendrobatidis
3–5 (width)
20 (length)
(Anon 2017)
Polio virus
0.03
(Kern and Krishnan 2006)
Aspergillus sydowii
2.5–4
(Anon 2017)
Human immunodeficiency viruses (HIV)
> 0.08
(Kern and Krishnan 2006)
Retroviridae
0.08–0.13
(Roberts et al 2010)
Reported sizes of some biologically hazardous microorganisms0.9–1.2 (width)4–6 (length)3–5 (width)20 (length)As it can be seen, HEPA filters can filter fungal spores and bacteria efficiently but may face problems filtering viruses. If the virus is contained in small droplets or aerosols not smaller than 0.3–0.5 microns, it will be suspended in air and eventually be retained in the filter. However, for smaller aerosol sizes, the filters could have a lower efficiency. It is in this case that methods based on virus deactivation could be a better choice. Almost all of them rely on first stages of suction of air and filtering of particles followed by a destructive treatment of the air stream. The treatment may involve ionization (Nunayon et al 2019), electric discharge (Pastuszka et al 2019), exposition to UV radiation (Krosney et al 2014), plasma treatment (Gallagher et al 2004), ozonization (Dubuis et al 2020), heating (Fiorenzano 1989, Matias 1999), etc.Thermal sterilization is a known robust and proven technique for the destruction of germs, both pathogenic and non-pathogenic. In its common form, it has high energy consumption, and for this reason its application for the sanitization of air is disfavored in comparison with other alternative techniques, particularly filtration. Continuous thermal sterilization of air is a simple concept that was first introduced in 1950–1960, when the needs for supplying sterile air to biological reactors appeared (Humphrey 1960). Elsworth et al. (1955) reported that an air sterilizer operated at 300 °C and a minimum residence time of 1.6 s could reduce the penetration of spores suspended in air to 1 in 470 million. The basic idea of thermal sterilization is to heat the air stream to a sufficiently high temperature (sterilization temperature), and to keep it at that temperature for some time (sterilization time) in order to effectively inactivate the microorganism. These devices were mainly aimed at removing spores, bacteria and fungi and were later left aside in favor of other more energy efficient and less costly sterilization device. Small commercial devices can be found for the thermal elimination of suspended allergens and bacteria though their market penetration is small. Patents of such sterilization device are reported elsewhere (Fiorenzano 1989, Matias 1999).The idea of thermal sterilization with a focus on virus inactivation is revisited in this work. In order to overcome the main problem of power consumption, an efficient heat integration between the inlet and outlet air streams is posed (see Fig. 1). Countercurrent heat transfer and a high surface area are expected to reduce the energy consumption, Qb < < Qa. Low values of energy consumed per unit of processed volume could be obtained with an adequate design of the thermal sterilization cell and the heat exchanger economizer.
Fig. 1
Air sterilization by heat treatment. a Without heat recovery. b With heat recovery. The heat source is an electric coil. is the mass flowrate of air, Cp is the specific heat capacity of air. Q is the heat consumption of the sterilizer
Air sterilization by heat treatment. a Without heat recovery. b With heat recovery. The heat source is an electric coil. is the mass flowrate of air, Cp is the specific heat capacity of air. Q is the heat consumption of the sterilizerA dynamic model of the heat transfer and pathogen concentration as a function of time was built and solved in this work in order to extract the main features of the system. At this proof-of-concept stage, the idea of thermal sterilizer with efficient heat recovery was validated by simulation only. A full validation for bio-hazardous environments would demand a specialized laboratory with high safety levels that is out of the scope of this work.This is a joint study performed at Universidad Nacional del Litoral (Santa Fe, Argentina), Universidad Nacional de Jujuy (San Salvador de Jujuy, Argentina) and Universidad Nacional de la Patagonia Austral (Río Gallegos, Argentina), from December 2020 to May 2021.
Materials and methods
The sterilization device
Process description
All magnitudes in the text and formulae will be expressed in SI units. The basic scheme of the sterilization device is depicted in Fig. 1. The air is forced into the sterilizer by a blower. The air first enters the economizer, i.e., the heat exchanger for heat recovery, and is heated there until the sterilization temperature is practically reached. Then, the air is passed through the sterilization cell where the heating is completed to the target sterilization temperature, i.e., 200–250 °C. Then, the air is maintained at that temperature in the sterilization cell for an adequate amount of time. The residence time can be adjusted to a few fractions of a second or some seconds, depending on the resistance of the targeted microorganisms. Some examples of deactivation of microorganisms with different deactivation times will be given later in this work. The sterilization cell needs to be conveniently insulated to prevent thermal losses. Finally, the air goes out from the sterilization cell through the economizer where it exchanges heat with the inlet stream. The presence of a heat recovery economizer has been suggested in early proposed continuous sterilization processes for liquid streams (Pfeifer and Vojnovich 1952, Whitmarsh 1954).The outlet temperature of the air is higher than the inlet temperature (room temperature). The magnitude of this temperature difference should be a function of the thermal efficiency of the economizer defined in Eq. (1).Appropriate equations for heat transfer and rate of removal of microorganisms will be written in order to make a model of the air sanitizer. Equations will be solved, and the influence of the process variables (air velocity, cell temperature) and sterilization device geometrical parameters (length-to-diameter ratio, surface area) will be assessed by means of simulation.
Sterilization as a chemical reaction and pathogens as reactants
Thermal sanitization is an activated process (Deindoerfer and Humphrey 1959). Deindoerfer (1957) early studied the sterilization of fermentation media and found that the reactivity in sterilization of microorganisms followed a simple Arrhenius law:where C is the microorganism density, r is the sterilization reaction rate, k is the rate constant, A is the pre-exponential factor, Ea is the activation energy, R is the universal gas constant, and T is the absolute temperature.Deindoerfer (1957) reported the value of the activation energy for the death of Bacillus stearothermophilus and compared it with data of Levine (1956) and Garrett (1956) for other microorganisms and complex molecules. Values of Ea in kJ mol−1 were folic acid = 70.3, d-panthothenyl alcohol = 87.9, cyanocobalamin = 96.6, thiamine hydrochloride = 108.8, Bacillus stearothermophilus strain 1518 = 283.2, Clostridium sporogenes PA 3679 = 302.9, Clostridium botulinum = 343.5.The different relative resistance of the microorganisms was long ago detected. Some microorganisms like thermophiles have optimal growth temperatures greater than 60 °C and can withstand common sterilization techniques, like exposure to steam at 120 °C for several minutes, whereas others are easily killed. Rahn (1945) found that bacterial spores were orders of magnitude more resistant to moist heat than viruses and bacteriophages. Sauerbrei and Wutzler (2009)found that dry heat inactivated different viruses at different rates: poliovirus type 1 > adenovirus type 5 > polyoma virus SV 40 > vaccinia virus > > bovine parvovirus.The fact that Eqs. (2) and (3) apply to thermal sanitization methods has a big impact on the operation of the sterilization device because small increases in the sterilization temperature lead to big increases in the processing rate and hence the processing capacity. On the other side too, low sterilization temperature can lead to incomplete sterilization of resistant microorganisms even at long treatment times. Transmission of B19 virus by ineffectively sterilized coagulation factors (treated with dry heat) has been reported in the literature (Santagostino et al 1997; Schneider et al 2004) despite of this treatment being broadly applied and being recommended for the inactivation of enveloped and non-enveloped viruses (Boschetti et al 2005).For the choice of an adequate sterilization temperature and sterilization time, values of A and Ea in Eq. (3) should be known for the target microorganisms. Many of these values have been collected from the literature sources and written in Table 2. With these values of the kinetic parameters, it is possible to integrate Eq. (2) to determine the time needed for a given percentage of inactivation of the microorganism at a given temperature. Most data on thermal resistance of microorganisms have been measured at temperatures lower than 150 °C. Therefore, any calculation at higher temperatures involves an extrapolation. In this sense, the mechanisms for thermal inactivation of microorganisms could be different in different temperature ranges, e.g., RNA denaturalization of viruses occurs at relatively low temperatures, while chemical reactions of the protein envelope are supposed to occur at higher temperatures.
Table 2
Heat resistance of different microorganisms. Values of the pre-exponential and activation energy of the constant k of the first-order reaction of thermal inactivation. k in min−1
Microorganism
ln(A)
Ea (kJ mol−1)
Refs
Lipopolysaccharides
24
96.7
Tsuji and Harrison (1978)
Clostridium tetani (NCTC 5411 and 5413)
23.9
151.8
Darmady et al (1961)
Hepatitis A virus
58.1
163.7
Bozkurt et al (2014)
RNA viruses (Hemorrhagic fever)
34.1
36.7
Madani et al (2014)
SARS-CoV-2
48.6
135.7
Yap et al (2020)
SARS-CoV-1
51.9
141.6
Yap et al (2020)
Gastroenteritis Virus-RH50
36.8
106
Yap et al (2020)
Clostridium Botulinum bacteria
105.2
307.9
Davey (1993)
Bacillus stearothermophilus spores
108.7
349.8
Wang et al (1964)
Bacillus stearothermophilus spores
104.5
339.8
Abraham et al (1990)
Bacillus ATCC 29,669 spores
44.4
167.7
Schubert and Beaudet (2011)
Escherichia Coli
89.9
247.6
Singh et al (2011)
Aspergillus Niger spores
––-
133–537
Fujikawa et al (2001)
Pichinde virus
––-
88.7–228
Allison et al (1985)
Heat resistance of different microorganisms. Values of the pre-exponential and activation energy of the constant k of the first-order reaction of thermal inactivation. k in min−1An a priori screening of sterilization temperatures indicated that temperatures should be higher than 100–120 °C in order to have high degrees of virus inactivation. A temperature of 150 °C was adopted in most of the simulations.Most of the previous data have been taken from experiments with liquid suspensions of the viruses, and a few correspond to sterilization in hot dry air. The possibility of airborne presence of microorganisms is, however, not an assumption but a well-documented fact in the case of bacteria (Smets et al 2016), viruses (Cox 1989) and fungal spores (Streifel et al 1989).Some examples of the needed sterilization time for different microorganisms at the same temperature and with the same inactivation degree can be calculated with the data of Table 2 and Eqs. (2–3). At 90 °C, if 99.99% inactivation is demanded, 104, 23 and 14 s are needed for the RH50 transmissible gastroenteritis virus (a), Clostridium Botulinum bacteria (b) and SARS-Co-V2 virus (c). At 100 °C, the needed sterilization times are 40, 1.5 and 4.2 s, respectively. It can be seen that the order of needed sterilization time (t) at 90 °C (t > t > t) is altered at 100 °C (t > t > t) because of the differences in activation energy.One obvious result from the inspection of Tables 1 and 2 is that spores of high thermal endurance have a much bigger size while viruses and bacteria of lower thermal resistance have a much smaller size. In this sense, thermal sanitization and filtration can be mutually complimentary. If a filter is placed before the thermal sanitizer, the microorganisms not retained in the filter can be inactivated at a relatively milder temperature.As for the chemical reactions involved in thermal sterilization, they should be related to thermally activated reactions of the microorganism constituents, i.e., proteins and lipids. For example, a virus is made up of a core of genetic material, DNA or RNA, surrounded by a protective coat called a capsid which is made up of different proteins. The capsid is sometimes surrounded by an additional coat with spikes called the envelope. Proteins are large biomolecules formed by long chains of amino acids. For example, the coronavirus of the COVID-19 pandemic has a core of RNA chain join to nucleoproteins and lipid bilayer envelope with spike glycoproteins and other small proteins which have 76–109 amino acids (Schoeman and Fielding 2019).Possible chemical changes could be: (1) Protein denaturation at temperatures higher than 60 °C, heat treatment producing the disruption of the hydrogen bonds of the non-polar hydrophobic interactions and of the electrochemical interactions, all of them responsible for the 3D organization of the protein; protein shape thus being lost. (2) Loss of non-structural water by evaporation at temperatures higher than 90–100 °C. (3) Water and ammonia formation reactions from amino acids, mainly at 230–270 °C (Weiss et al 2018).
The economizer and the cell
The economizer is the heat recovery exchanger coupled to the sterilizing cell. The different reactions and temperature ranges pointed out in the previous paragraph suggest that some of the reactions might actually occur in the economizer rather than the sterilizing cell.Apart from the hydraulic and heat transfer design, one basic problem is that of the choice of the material for constructing the economizer. Economizers are made with a variety of metals, but the most common are stainless steel, aluminum, copper, steel, brass. Air poses no corrosion problems. For efficient heat transfer, a good thermal conductor is appreciated and the values of this magnitude could be inspected (Abu-Eishah 2001) (conductivity in W m−1 K−1 in brackets): aluminum (240), copper (400), iron (55), silver (420), high Cr-Ni stainless steel (15), bronze (50–100). Copper and aluminum have the highest thermal conductivity, whereas steel and bronze have the lowest. Silver is too expensive to be considered for the application.Good thermal conductivity is an advantage, but too highly conductive materials may prove a bad choice too. Axial conduction in the direction of the gas flow and along the metal walls can prove to be detrimental to the heat integration if high values of heat recovery are needed. In this sense, stainless steel walls of small thickness in the economizer could provide a sufficiently low heat resistance while minimizing the axial conduction effect.Another effect of the metal is its catalytic action for some reactions with sanitizing effect. Most metals have negligible effects, but silver and copper have been found to have sterilizing properties. Particularly, copper reduces the half-life of viruses and bacteria deposited on its surface at least one order of magnitude with respect to other materials (Michels et al 2015; Warnes et al 2015). No such effect is, however, expected at the short residence time values (few seconds) involved in air sterilization.On the basis of good mechanical resistance, weldability and low cost, stainless steel is chosen as material for both the heat exchanger and the sterilizing cell.In this work, an unbaffled shell-and-tube heat exchanger is used as an example of economizer (see Fig. 2). This choice is based on simplicity for calculation for a proof-of-concept design. This kind of sterilization device could anyway have some advantages for maintenance since it can be easily disassembled and cleaned to remove deposits of organic material and dust. The sterilization cell is designed as one tube homogeneously heated by an electrical resistance.
Fig. 2
Example of implementation of the sterilization cell with heat recovery. Economizer is a shell-and-tube heat exchanger in this case
Example of implementation of the sterilization cell with heat recovery. Economizer is a shell-and-tube heat exchanger in this case
The target space
The air sterilizer can be placed in many target spaces like hospital rooms, ambulances, etc. For hospital rooms, recommended ventilation rates for clearance of pathogens are ACH = 10–12 h−1 and minimum ventilation periods of 20 min or higher (Public Health England 2020). ACH is the number of changes of the volume of the system per hour. Once the ACH and the volume of the target space are indicated, the resulting air flowrate can be used for the design and optimization of the air sterilizer. An ACH of 1–10 h−1 and a hospital room of 36 m3 were considered in the model, giving flowrates of 36–360 m3 h−1.
The mathematical model
In the proposed mathematical model, the cold air stream coming from the room is supposed to enter the economizer in the tubes side. The properties of this stream are denoted with the subscript “i”. The hot air stream leaving the sterilizing cell is supposed to flow through the shell of the economizer, and their properties are denoted with the subscript “o”. The properties of the wall of a tube are denoted with the subscript “w”.The model for the phenomena occurring in the countercurrent economizer is depicted in Eqs. (4)-(8). Equation (4) is the differential energy balance for the cold air in a tube. Equation (5) is the differential molar balance of the microorganism in a tube. Equation (6) is the differential energy balance for the wall of a tube. Equation (7) is the differential energy balance for the hot air stream (shell side), and Eq. (8) is the differential molar balance for the microorganisms in the shell side of the economizer.T is the temperature, v is the air velocity, h is the heat transfer coefficient, P is the tube perimeter, A is the flow cross-sectional area, ρ is the air stream density, CP is the air specific heat capacity at constant pressure, C is the concentration of microorganisms and r is the sterilization rate.The model for the sterilizing cell (or heater) is depicted in Eqs. (9–11). Variables for the heater are denoted with the “h” subscript.Equations (9) and (10) are the differential energy balance in the wall and in the air stream, respectively. Equation (11) is the differential molar balance of the microorganism in the sterilizing cell. Q is the input power, and Lh is the heater length.The initial conditions are depicted in Eqs. (12) and (13) in which ze and zh are the axial coordinates of the economizer and the heater, respectively, and Troom is the room temperature.Boundary conditions must be written at the entrance, Eqs. (14) and (15), outlet, Eqs. (16) and (17), and at the points connecting the heater to the economizer, Eqs. (18)-(19). Teco and Ceco are the temperature and the microorganism concentration of the stream leaving the economizer tubes. Croom is the microorganism concentration in the room air. Theater and Cheater are the temperature and the microorganism concentration of the stream leaving the heater. Le is the economizer length. Tout and Cout are the temperature and the microorganism concentration of the sterilized air stream at the exit.The input power Q should not be constant but rather subjected to a control scheme. A simple proportional control scheme (Luyben 1990) is written in Eqs. (22)-(23). AcT is the proportional control action, AbT is the bias, kP is the proportional gain, eT is the error, xT is the limited control signal, Tsp is the setpoint, and Qmax is the maximum power delivered by the heater.The system of Eqs. (4)-(21) was numerically solved by discretizing the heat recovery exchanger into (N-1) intervals and the sterilizing cells also into (N-1) intervals. Partial derivatives were replaced by finite differences. In this way, the system was reduced to a system of first-order ODEs depicting the variation of the temperature and concentration of microorganisms in each node.Pressure drop (ΔP) in the tubes, in the sterilizing cell and in the shell was calculated by using Eq. (26). The friction factors f were calculated with the correlations due to Bhatti and Shah (Kakaç et al 1988), Eq. (27). For the shell, the same equation was used but changing the normal diameter D by the hydraulic equivalent diameter. The value of the total pressure drop was used for calculating the power for moving the air through the sterilizer but not for correcting the pressure in the equations of the differential energy and mass balances. It was considered that if the pressure drop was not significant, a correction was not needed. Heat transfer coefficients for turbulent flow were obtained from the correlation of Sleicher and Rouse (Sleicher and Rouse 1975), Eqs. (28–30). For laminar Reynolds, a constant Nu = 4.364 was considered.The tasks of simulation and equation solving were performed in GNU Octave for Windows. With respect to the control of the accuracy of the method, discretization was increased until an error lower than 5% was found in the global thermal balance between the hot and cold streams of the economizer. Time integration of all dependent variables was performed with a relative tolerance of 10–6.
Influence of the axial conduction through the metal
In Eq. (6), a term including the transfer of heat by conduction along the metal walls was not written. Heat transfer degradation due to axial conduction of heat is, however, possible. In this sense, some authors (Baek et al 2012; Kroeger 1967) have obtained full solutions for countercurrent plate-fin heat exchangers and plotted efficiency or inefficiency in terms of the λ parameter, Eq. (31), Cmin/Cmax and the NTU. Cmin and Cmax are the minimum and maximum heat capacity rates (in W K−1) of the streams, and NTU is the number of transfer units, Eq. (32). For a countercurrent heat exchange between two streams of equal heat capacity rate, as in the air sterilizer, Cmin/Cmax = 1, and the flow is said to be “balanced”. For balanced flows, the authors predict that for NTU > 20 and λ < 0.02, the efficiency ε, Eq. (33) is greater than 95%.At is the total area for heat transfer of the heat exchanger. U is the global heat transfer coefficient. kw and Aw are thermal conductivity and total cross area of the metal walls.Inspection of the definition of λ shows that too high thermal conductivity metals can bring problems to the efficiency of the heat exchanger, and that high L/Aw sterilization device has an advantage. In this sense, the axial conduction can be reduced if L is increased and Aw decreased. For tubular heat exchangers, this implies a high L/D ratio.The system was not modeled with axial conduction, and heat transfer efficiency was kept high by adopting exchanger configurations with λ lower than 0.02.
Results and discussion
The sterilizer is supposed to be placed in a small room with 36 m3 of air volume. In order to accurately calculate the air properties, they were interpolated from tabulated experimental values (Green and Perry 2008). Properties of the system are detailed in Table 3. A full solution of the system, Eqs. (2–25), using the finite differences method, is presented in the upcoming figures.
Table 3
Values of the process variables and design parameters of the sterilization device in the basic example
Economizer
Process variables
Tubes length, Le (m)
8
Room temperature, Troom (°C)
25
Shell diameter (m)
0.06
Temperature set point, Tsp (°C)
200–300
Number of tubes
100
Max. heating power, Qmax (W)
300–9000
Tubes outer diameter (m)
0.0048
Air flowrate, Fv (m3 h−1)
36–360
Tubes thickness (m)
0.0007
Sterilizing cell
Tubes material
Steel
Length, Lh (m)
2
Simulation
Internal diameter (m)
0.034
z nodes, economizer
100
Wall thickness (mm)
1
z nodes, sterilizing cell
100
Material
Steel
Simulation total time (h)
1–4
Values of the process variables and design parameters of the sterilization device in the basic exampleAbout 2 h are needed to reach the steady state. This is checked by inspection of the temperature traces of Fig. 3(a, b) and the power consumption plot of Fig. 3d. Figure 3c shows the steady-state temperature traces of the economizer. These are perfectly linear. This is typical of economizers of autothermal reactors that have equal mass flow rates in both sides (Froment et al 2010). However, during the transient period, the traces have a parabolic-like pattern. Depending on the maximum power of the heater, the temperature of the cell can rapidly reach the setpoint like in (b). The heater setpoint is always reached before the economizer reaches the steady state.
Fig. 3
Economizer temperature (T) as a function of position (z) and time (t). a
T versus z, Tsp = 200 °C, Fv = 36 m3 h−1, Qmax = 300 W. b Idem, Qmax = 1 kW. c
T versus z, steady-state. d Power as a function of t, Qmax = 1 kW
Economizer temperature (T) as a function of position (z) and time (t). a
T versus z, Tsp = 200 °C, Fv = 36 m3 h−1, Qmax = 300 W. b Idem, Qmax = 1 kW. c
T versus z, steady-state. d Power as a function of t, Qmax = 1 kWEnergy consumption is the summation of two components. The first one is the net heating power consumed, i.e., power transmitted to the cold stream minus the power recovered in the economizer. The second one is the energy consumed by the blower that moves the air through the sterilizer.During the warming-up of the device, the value of the power consumption is initially the maximum power available (Qmax). In the steady state, the consumption is 96 W, i.e., only 10% of the maximum value, Fig. 3d. The consumed power is proportional to the temperature difference between the inlet and outlet air streams. The temperature difference is 8.2 °C. This temperature corresponds to an efficiency of heat recovery in the economizer of ε = 95.3%. The efficiency is defined in Eq. (33). The pressure drop in the sterilizer is 70 mbar and the pumping power, 70 W. The flow inside the sterilizer is laminar, Re about 2000, and the heat transfer coefficients are rather low, about 40 W m−2 K−1.With the chosen air sterilization rate for the example of Fig. 3, the air volume of a big room, like that of an intensive care room, could be sterilized in 1 h. The sterilization effectiveness depends on the thermal death rate along the sterilizer. Figure 4 shows traces of the C/Croom ratio during the sterilization of some known viruses. SARS-CoV-2 and the other two checked viruses are practically dead at the entrance of the sterilizing cell, i.e., all virus entities have been killed when heating from room temperature to 200 °C. The death rate becomes significant at 5 m, corresponding to a tube temperature of 120 °C. The rate is, however, negligible for lengths lower than 4 m, when the temperature is lower than 100 °C.
Fig. 4
Thermal death of viruses. Relative concentration in air as a function of the length along the sterilizer. SARS-CoV-1 virus (v1), SARS-CoV-2 virus (v2), Transmissible Gastroenteritis Virus-RH50 (v3), Hemorrhagic fever virus (v4)
Thermal death of viruses. Relative concentration in air as a function of the length along the sterilizer. SARS-CoV-1 virus (v1), SARS-CoV-2 virus (v2), Transmissible Gastroenteritis Virus-RH50 (v3), Hemorrhagic fever virus (v4)The results of high degree of virus deactivation of Fig. 4 are a consequence of the values of the pre-exponential factor and activation energy of the kinetic constant of thermal death of Table 2. Positive or negative deviations could possibly be found in a real experiment, but the global pattern is expected to be the same. If the real pathogen deactivation degree was found to be low, its value could be easily tuned by small changes in the cell temperature due to the very high sensitivity of the Arrhenius-like thermal death rate. In this sense, real-life experiments to refine the model could be spared due to the robust adaptability of the system.Discretization of the z domain introduced a small error. To assess this error, an integral heat balance of the economizer was made at steady-state conditions. The result indicated that the error was 6% for N (number of nodes) equal to 20, 4% for N = 40, 2% for N = 100 and 1% for N = 200. N = 200 was adopted for most calculations.The heat recovery efficiency and the pressure drop were found to be strong functions of the air flow rate. If 3–6 room air replacements by hour were the target, then the flow rate must be increased 3–6 times with respect to the base case, and the pressure is especially sharply increased. Figure 5 shows this.
Fig. 5
Influence of flow rate on process properties (virus destruction > 99.9999%). (filled square) Pressure drop (mbar), (filled circle) Pumping power × 0.1 (W), (open triangle) Heating power (W), (filled triangle) Heat recovery efficiency ε (%), (diamond symbol) Heat transfer coefficient (W m−2 K−1)
Influence of flow rate on process properties (virus destruction > 99.9999%). (filled square) Pressure drop (mbar), (filled circle) Pumping power × 0.1 (W), (open triangle) Heating power (W), (filled triangle) Heat recovery efficiency ε (%), (diamond symbol) Heat transfer coefficient (W m−2 K−1)Increasing the flow rate has advantages and disadvantages. If heater cell and residence time are adequate for virus inactivation, as in this case, the only limitations for increasing the air sterilization capacity are the heating and pumping power. Figure 5 shows that increasing the air velocity also increases the heat transfer coefficient, which is good for maintaining the efficiency for heat recovery in all cases (≈ 95%) despite the higher flow rate. However, both heating power and pumping are also increased. As the flowrate is increased four times, the heating power is increased three times. The heating power consumption per unit flow rate (W per m3 h−1) is therefore almost not affected. The pumping power is, however, greatly increased from 36 to 2300 W, and the pressure drop goes from 36 to 588 mbar. It is clear that the main limitation for the use of the sterilizer is the pressure drop at high flow rates. This consequence is unavoidable because narrow channels appear naturally in high surface area geometries needed for efficient heat recovery. The maximum air sterilization rate with acceptable pressure drop seems to be about 100 m3 h−1. For this condition, the temperature of the sterilized air is 7.3 °C hotter than the room temperature.The influence of the ratio of the heat transfer area to the area for air flow (β) is depicted in Fig. 6. High β ratios favor the heat recovery, lowering the consumption of thermal power. However, the main problem is again the steep increase in the pumping power and pressure drop as the area for air flow is reduced. Values of the β ratio higher than 10,000 seem prohibitive in terms of pumping power. On the other side, values lower than 5000 increase the heating power also too much and increase the sterilized air temperature more than 15 °C over the room temperature (low heat recovery). This is due to the low value of the heat transfer coefficients in the region of laminar flow at small β ratios.
Fig. 6
Influence of β = heat transfer area/flow area. Constant heat transfer area, other conditions as in Table 3, Fv = 108 m3 h−1. (filled square) Pressure drop (mbar). (filled circle) Pumping power × 0.1 (W). (∆) Heating power (W). (filled triangle) Heat recovery efficiency × 1000
Influence of β = heat transfer area/flow area. Constant heat transfer area, other conditions as in Table 3, Fv = 108 m3 h−1. (filled square) Pressure drop (mbar). (filled circle) Pumping power × 0.1 (W). (∆) Heating power (W). (filled triangle) Heat recovery efficiency × 1000Finally, the influence of the temperature of the heater should be assessed. A plot similar to that of Fig. 4 is included in Fig. 7. Now, the thermal death traces for SARS-CoV-2 and Bacillus sp. ATCC 29,669, at three different temperatures, are included. The indicated spores have one of the highest thermal resistance recorded in hot air (Schubert and Beaudet 2011).
Fig. 7
Influence of the sterilizing cell temperature. 200 °C (solid line), 270 °C (dash line), 300 °C (dotted line). Air flow rate of 36 m3 h−1. Rest of the data as in Table 3
Influence of the sterilizing cell temperature. 200 °C (solid line), 270 °C (dash line), 300 °C (dotted line). Air flow rate of 36 m3 h−1. Rest of the data as in Table 3The results indicate that the heater temperature must be increased to 300 °C to kill all spores, but 200 °C is enough for deactivating SARS-CoV-2. In the case of the spores, the length of the sterilizing cell could be increased to achieve a reduction of 106 in the C/Croom ratio. Increasing the temperature from 200 to 300 °C does not modify the heat recovery efficiency, which stays at the same value of 95.4%. The temperature of the sterilized air is, however, increased due to the higher temperature difference between the cell and the room temperatures. At 300 °C, there is a 12 °C difference between the room air and the sterilized air.The results so far shown indicate that the heat recovery efficiency depends only on the flow dynamics and the available surface area. For this reason, it is advantageous to keep a rather high cell temperature to increase the thermal death rate and hence the sterilizing capacity. A high thermal death rate reduces the needed residence time and then a given sterilization efficiency can be got with a shorter cell and shorter economizer. The logic of better short-time high temperature than long-time low temperature seems clear.
Comparison with other sanitization devices
Many technologies have emerged in the last years that perform the sanitization of air. Among them, UV treatment and filtering are the most common. With respect to the latter, some kind of filtering is included in most applications but single filtering can be a stand-alone technique if HEPA filters are used.UV. Advantages: medium energy consumption; high efficiency if coupled with HEPA filtration. Disadvantages: relatively high maintenance cost (lamp replacement); few reports on virus removal efficiency; low efficiency for removing spores. Examples: (a) fungi and bacteria with 2–110 CFU m−3 in rooms, removal of 78% fungi and 62% bacteria (continuous flow UV sterilizer + filter, air flowrate, 0.11 m3 s−1, 0.11 units m−2) (Guimera et al 2018). (b) Removal of 90% Serratia (bacillus) and 99.99% Aspergillus (fungus) (continuous flow UV sterilizer + filter, air flowrate 4.5 m3 s−1, 72 W lamps, 0.5 s exposure time, 413 m s−1 air speed, 3744 h lamp life (Kowalski and Bahnfleth 2000). (c) 99.5 + % removal of Staphylococcus aureus, Staphylococcus epidermidis, Serratia marcescens, Bacillus subtilis, 67% removal of Aspergillus niger (continuous flow UV sterilizer + filter, 0.5 s irradiation time, 254 nm UV lamps) (Nakamura 1987).Ionization. Advantages: —. Disadvantages: Few reports on virus removal efficiency. Examples: 99 + % removal of Staphylococcus aureus with ionic breeze air purifier, 6 h discontinuous operation (Ko and Burge 2007).Cold plasma. Advantages: —. Disadvantages: —. Examples: a) 20–70% removal of Escherichia coli, Pseudomonas alcaligenes, Staphylococcus epidermidis (cold plasma continuous sanitizer, 2–7 m s−1 air velocity) (Lai et al 2016). b) room with 6000 CFU m−3, 31–89% removal of Escherichia coli (plasma + ionic wind, 4.5 m s−1 air velocity) (Prehn et al 2020).Filtration. Advantages: Low energy consumption. High efficiency for bacteria and fungi. Disadvantages: Inefficient filtration of viruses in small aerosols. Filters must be disposed as hazardous medical waste. Needs UV germicidal irradiation if growth of microorganisms on surfaces is to be stopped. Need of prefilters to avoid clogging by dust and particulate. Laminar flow demands air velocities of 0.3–0.5 m s−1 leading to big filter areas. Filter replacement can be frequent. Examples: (a) Aerosolized suspensions of 104 mL−1
Staphylococcus aureus, 104 mL−1
Escherichia coli, 108 mL−1 T7 virus; 99 + % removal (commercial electronic air filter, aerosol size not given) (Malaithao et al 2009). (b) 105 CFU in air; 99.97% removal of MS2 Coli phagus virus (continuous air purifier with HEPA filter, air velocity of 2 cm s−1, aerosol size not given) (Wilkes et al 2000). c) 95 + % removal of virus with aerosol diameters of 0.25–1 μm; practically 100% for diameters higher than 2.5 μm SARS-CoV-2 aerosols are about 30–90% smaller than 0.25 microns depending on sampling place; continuous air purifiers with HEPA filter, 0.1–0.28 Watt (m3 h−1)−1; filters recommended to be collected and disposed as hazardous medical waste; intensive care unit with virus emission of 31–113 copies m−3 h−1 (Chen et al 2019; Liu et al 2020).Heat. Advantages: high removal rates possible; robust, simple construction and operation; practically no maintenance needed except for cleaning; high air velocities possible. Disadvantages: high power consumption if no economizer is used; heat is dissipated into the room; important pressure drop in heat recovery exchanger. Example: removal of 99.9999 + % virus, 99.9999 + %, bacteria 99 + % fungi; tubular thermal sanitizer, 36–144 m3 h−1, 150–250 °C cell temperature (this work).Filtration and thermal treatment seem to be the alternatives with maximum efficiency for a wide set of pathogens in air. Main advantage for filtration is the low energy consumption, while its main disadvantages are bacteria growth, probable incomplete removal of small viruses and frequent maintenance and replacement. For thermal sterilizers, the main advantage is robustness and small maintenance, while high pressure drop in the economizer at high air flow rates seems to be the main disadvantage.
On the practical application of thermal deactivation
The thermal sanitizer was designed to be used in hospital rooms. These are contaminated, closed places with likely hazardous concentrations of known pathogens. A hazardous concentration is one that leads to an intake dose higher than the minimum infective dose for a short time of residence in the room, e.g., 10 min. Intake should be calculated on the basis of a normal breathing frequency, i.e., 6 L min−1. Pathogens detection and identification should be performed with standard techniques such as air sampling and retention on filters, plaques, liquid impingers, followed by replication and counting (measurement of concentration) and visual inspection or specific testing (identification) (Pan et al 2019).Sterilization of air is a dynamic process depending on the presence of multiple sources and sinks. Sources are contaminated people, e.g., patients in the room that emit pathogens through breathing and coughing. Sinks are related to settling of pathogen particles on room surfaces, natural death, withdrawal of air by ventilation, and sterilization itself (Hussein et al 2009; Riediker and Tsai 2020).The air of the room is recycled through the sterilizer. This is a common feature with other flow-through systems, independent of the deactivation technique (UV, filtering, ozone, etc.). In the steady-state of a given system, the pathogens emission rate is equal to the sterilizing rate. Therefore, the sterilizer must be designed with a flowrate, cell temperature and residence time that allows balancing the emission rate. A simulation of a given situation is considered to be out of the scope of this article, but the general idea and the fundamental equations have been laid clear.
Conclusion
This work revisited the idea of air sterilization by heat treatment. The original idea of single sterilizing cell was modified by introducing high efficiency heat recovery with a countercurrent economizer. Fundamental data related to the kinetics of thermal inactivation of microorganisms were compiled from literature sources. The problem was mathematically analyzed, and then, transient and steady-state solutions for power consumption, temperature distribution and virus concentration were found by solving the corresponding equations numerically. The simulation results are considered a valid proof-of-concept. The main conclusions are:Big spores require rather high temperatures (> 270 °C) for thermal destruction, while smaller viruses and bacteria require lower temperatures for inactivation (< 200 °C).The fundamental variable for thermal inactivation of microorganisms is the temperature. High-temperature short-time treatments are more convenient than low-temperature long-time ones, the latter leading to prohibitive big cell volumes.Despite the possible uncertainty in thermal death data, the Arrhenius dependence leads to an exponential growth of the death rate, enabling total removal by appropriate adjustments of the sanitizing temperature.The key solution for operating a thermal sterilizer with a relatively high temperature is the heat integration of the process streams. Efficient heat integration is achieved by high heat transfer areas and coefficients and a countercurrent flow pattern.An example of a shell-and-tube heat exchanger coupled to a sterilization cell was simulated. A sterilization device with a volume of about 26 L and 9 m2 heat transfer area sanitized air with a virus removal efficiency of 99.9999 + % with the cell operated at 200 °C, a flow rate of 36 m3 h−1 and a heat recovery efficiency of 95%.Thermal sanitization of air proves to be robust and simple and with a relatively small heat signature if efficiencies of heat recovery are greater than 90%. Main problem is the relatively high pressure drop in the economizer at high flow rates.