Literature DB >> 35114742

Diagnostic performance of the fully automated Roche Elecsys SARS-CoV-2 antigen electrochemiluminescence immunoassay: a pooled analysis.

Giuseppe Lippi1,2, Brandon M Henry1,3,4, Khosrow Adeli1,5.   

Abstract

OBJECTIVES: Among the diagnostic tests that have recently become commercially available for diagnosing coronavirus disease 2019 (COVID-19), the fully-automated Roche Elecsys severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen electrochemiluminescence immunoassay (ECLIA) is one of the most widespread for its adaptability within a system of laboratory automation, rapidity and high-throughput. This article is aimed to provide the results of the first pooled analysis of its accuracy for diagnosing SARS-CoV-2 infections. CONTENT: We carried out an electronic search in Scopus and Medline, without language or date restrictions (i.e., up to January 18, 2022), to identify articles where the diagnostic performance of Roche Elecsys SARS-CoV-2 antigen ECLIA was compared with that of reference molecular diagnostic techniques.
SUMMARY: Overall, 11 studies were identified, 10 of which (n=6,095 swabs) provided necessary data for inclusion in a pooled analysis. The pooled diagnostic sensitivity, specificity and area under the curve (AUC) in nasopharyngeal samples were 0.68 (95%CI, 0.66-0.70), 0.99 (95%CI, 0.99-0.99) and 0.958 (95%CI, 0.936-0.980), respectively. The cumulative observed agreement with reference molecular assays was 89.5% and the kappa statistic was 0.735 (95%CI, 0.716-0.754). The pooled diagnostic sensitivity in samples with high viral load (i.e., cycle threshold values <28-30) was 0.95 (95%CI, 0.92-0.97). OUTLOOK: The results of this pooled analysis confirm that the fully-automated Roche Elecsys SARS-CoV-2 antigen ECLIA has high diagnostic specificity and optimal diagnostic sensitivity for identifying nasopharyngeal samples with higher viral load, thus making it a reliable technique for mass screening and for supporting strategies based on shorten isolation and/or quarantine.
© 2022 Walter de Gruyter GmbH, Berlin/Boston.

Entities:  

Keywords:  COVID-19; SARS-CoV-2; antigen; diagnosis; immunoassay

Mesh:

Substances:

Year:  2022        PMID: 35114742     DOI: 10.1515/cclm-2022-0053

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  1 in total

Review 1.  LumiraDX SARS-CoV-2 Antigen Test for Diagnosing Acute SARS-CoV-2 Infection: Critical Literature Review and Meta-Analysis.

Authors:  Giuseppe Lippi; Brandon M Henry; Mario Plebani
Journal:  Diagnostics (Basel)       Date:  2022-04-11
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.