| Literature DB >> 35107557 |
Natália de Araújo Ferreira1, Arthur de Sá Ferreira1, Fernando Silva Guimarães2.
Abstract
OBJECTIVE: This systematic review was designed to assess the usefulness of cough peak flow to predict the extubation outcome in subjects who passed a spontaneous breathing trial.Entities:
Mesh:
Year: 2021 PMID: 35107557 PMCID: PMC8555400 DOI: 10.5935/0103-507X.20210060
Source DB: PubMed Journal: Rev Bras Ter Intensiva ISSN: 0103-507X
Figure 1Selection of studies included in this meta-analysis.
Cinahl - Cumulative Index of Nursing and Allied Health Literature; SciELO - Scientific Electronic Library Online; BVS - Biblioteca Virtual em Saúde.
Characteristics of the included studies
| Study | n | Age (years) | Duration of MV (days) | Cough assessment | Measuring instrument | Definition of extubation failure | Rescue therapy | Cutoff from ROC curve |
|---|---|---|---|---|---|---|---|---|
| Smailes et al.( | 125 | Extubation failure: 44 (27 - 70.4) Extubation success: 38 (34 - 43.6) | Extubation failure: 20 (13.3 - 28) Extubation success:6 (4 - 7) | Voluntary (coached) | Mini-Wright peak flow meter | Reintubation within 48 hours | No | No |
| Smina et al.( | 115 | Extubation failure: 62.5 ± 5.8 Extubation success: 64.1 ± 1.7 | Extubation failure: 3.7 ± 0.1 Extubation success: 3.3 ± 0.2 | Voluntary (coached) | Peak flow meter (nonspecified model) | Reintubation within 72 hours | No | Yes |
| Beuret et al.( | 130 | Extubation failure: 70 ± 16 Extubation success: 62 ± 17 | Extubation failure: 9.5 (7 - 18) Extubation success: 8 (4 - 16) | Voluntary (coached) | Pocket spirometer (Piko-1) | Reintubation within 48 hours | Yes, NIV | Yes |
| Salam et al.( | 88 | Extubation failure: 62.0 ± 4.7 Extubation success: 62.4 ± 1.9 | Extubation failure: 6.3 ± 1.9 Extubation success: 5.6 ± 0.6 | Voluntary (coached) | Pneumotachograph (Aztech peak flow meter) | Reintubation within 72hours | No | No |
| Duan
et al.( | 356 | CPF ≤ 70L/minute (NIV): 73 ± 12 CPF ≤ 70L/minute (Control): 74 ± 13 CPF > 70L/minute (NIV): 67 ± 14 CPF > 70L/minute (Control): 58 ± 19 | CPF ≤ 70L/minute (NIV): 8 ± 12 CPF ≤ 70L/minute (Control): 7 ± 5 CPF > 70L/minute (NIV): 7 ± 5 CPF > 70L/minute (Control): 5 ± 4 | Voluntary (coached) | Spirometer (Chest- graph HI-101) | Reintubation within 72hours | Yes, NIV | No |
| Su
et al.( | 150 | Extubation failure: 68.0 (20.0 - 88.0) Extubation success: 66.0 (20.0 - 95.0) | Extubation failure: 4.5 (3.0 - 28.0) Extubation success: 4.0 (3.0 - 24.0) | Involuntary (saline instillation) | Hand-held respiratory mechanics monitor (nonspecified model) | Reintubation until hospital discharge | No | Yes |
| Duan
et al.( | 115 | Extubation failure: 73.95 ± 15.43 Extubation success: 68.42 ± 15.12 | Extubation failure: 9.58 ± 5.84 Extubation success: 5.80 ± 5.55 | Voluntary and Involuntary (saline instillation) | Spirometer (Chest- graph HI-101) | Reintubation within 72hours | Yes, VNI | Yes |
| Duan
et al.( | 186 | Extubation failure: 73.6 ± 14.0 Extubation success: 68.3 ± 16.0 | Extubation failure: 8.6 (5.3) Extubation success: 7.4 (10.5) | Voluntary (coached) | Spirometer (Chest- graph HI-101) | Reintubation within 72hours | No | Yes |
| Kutchak et al.( | 135 | Extubation failure: 73.95 ± 15.43 Extubation success: 68.42 ± 15.12 | Extubation failure: 11.46 ± 6.26 Extubation success: 7.21 ± 4.85 | Involuntary (saline instillation and catheter) | Spirometer (Chest- graph HI-101) | Reintubation within 48 hours | No | Yes |
| Bai
et al.( | 126 | Extubation failure: 77 ± 13 Extubation success: 66 ± 14 | Extubation failure: 9.3 ± 4.4 Extubation success: 4.9 ± 4.1 | Voluntary (coached) | Mechanical ventilator display (PB840, Covidien) and Spirometer (Chest- graph HI-101) | Reintubation within 72hours | No | Yes |
| Gobert et al.( | 92 | Extubation failure: 71 (65 - 78) Extubation success: 69 (60 - 75) | Extubation failure: 8 (5 - 11) Extubation success: 4 (3 - 11) | Voluntary (coached) | Built-in flow meter (hot wire technology, Spirlog, EvitaXL, Drager) | Reintubation within 48 hours | Yes, NIV and MI-E | No |
| Xiao
et al.( | 139 | Extubation failure: 77 ± 11 Extubation success: 63 ± 19 | Extubation failure: 9.0 ± 5.6 Extubation success: 5.7 ± 4.3 | Voluntary (coached) | Spirometer (Chest- graph HI-101) | Reintubation within 72hours | No | No |
MV - mechanical ventilation; ROC - Receiver Operating Characteristic; CPF - cough peak flow; NIV - noninvasive ventilation; MI-E - mechanical insufflation-exsufflation. Results expressed as mean or median (95% confidence interval), mean ± standard deviation; median (interquartile range) or median (range).
Predictive power of the peak cough flow of the included studies
| Study | Cutoff (L/min) | AUC (%) | Sensitivity (%) | Specificity (%) | Predictive value + | Predictive value - | Likelihood ratio + | Likelihood ratio - | Relative risk | Odds ratio |
|---|---|---|---|---|---|---|---|---|---|---|
| Smailes et al.( | 60.0 | - | - | - | - | - | - | - | 9.100 | 1.060 |
| Smina et al.( | 60.0 | 70.0 | 69.0 | 74.0 | - | - | - | - | 5.100 | - |
| Beuret et al.( | 35.0 | - | 79.0 | 71.0 | - | - | 2.720 | 0.290 | 6.900 | - |
| Salam et al.( | 60.0 | - | 76.9 | 65.7 | - | - | 2.200 | - | 4.800 | - |
| Duan
et al.( | 70.0 | - | - | - | - | - | - | - | - | - |
| Su
et al.( | 58.5 | 80.2 | 78.8 | 78.1 | 93.0 | 50.0 | - | - | - | 0.950 |
| Duan
et al.( | 62.4 | 74.3 | 85.0 | 64.2 | - | - | - | - | - | - |
| Duan
et al.( | 49.8 | 63.2 | 70.0 | 66.3 | - | - | - | - | - | - |
| Duan
et al.( | 62.4 | 67.8 | 82.1 | 55.1 | - | - | 1.830 | 0.320 | - | - |
| Kutchak et al.( | 80.0 | - | - | - | - | - | - | - | 3.600 | - |
| Bai
et al.( | 56.4 | 79.0 | 73.0 | 87.0 | 42.3 | 96.0 | 5.430 | 0.310 | - | - |
| Bai
et al.( | 56.0 | 83.0 | 73.0 | 85.0 | 39.3 | 95.9 | 4.790 | 0.310 | - | - |
| Gobert et al.( | 60.0 | 61.0 | 70.4 | 63.6 | 93.4 | 22.6 | - | - | - | - |
| Xiao
et al.( | 60.0 | - | - | - | - | - | - | - | - | 0.975 |
AUC - area under the curve. *Voluntary cough; †involuntary cough; ‡spirometer; §mechanical ventilation.
Figure 2Assessment of the risk of bias of the included studies (Quality Assessment of Diagnostic Accuracy Studies 2 - QUADAS 2).
Figure 3Group bar charts showing the risk of bias and applicability concerns of the twelve included records using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).
Figure 4Pooled summary of positive and negative likelihood ratios of the included studies.
Figure 5Diagnostic accuracy of the cough peak flow for the extubation outcome: pooled odds ratio and summary Receiver Operating Characteristic curve.
ROC - Receiver Operating Characteristic; 95%CI - 95% confidence interval; AUROC - under Receiver Operating Characteristic.
Figure 6Deeks’ funnel plot asymmetry test for publication bias across studies.
SSE - sample size-effectiveness. Significant asymmetry (p = 0.043) indicates the presence of publication bias.