Dysrhythmias after direct-current cardioversion.

B Waldecker, P Brugada, M Zehender, W Stevenson, H J Wellens.   

Abstract

The success rate of direct-current (DC) countershocks and postshock arrhythmias are of concern for the design of automatic devices. Results of 112 DC shocks for induced ventricular tachycardia/fibrillation (VT/VF) (n = 99) or atrial fibrillation (AF) were analyzed. Clinical and arrhythmia characteristics were related to the success rate of DC shocks as well as postshock arrhythmias. Sixty-one patients were men and 14 were women; mean age was 52 +/- 15 years. Coronary artery disease was present in 56 patients and cardiomyopathy in 4. The other patients had no apparent structural heart disease. The success rate of transchest DC shocks for VT and VF were identical. The first DC shock interrupted 80% of VT and VF episodes. All episodes were terminated by 4 or fewer DC shocks. A single DC shock changed morphologic pattern or rate of 4 episodes of VT. Asystole after VT/VF (1,900 +/- 960 ms) was longer than after atrial fibrillation (1,150 +/- 470 ms, p less than 0.01). VT/VF recurred (within 3 minutes) after 26 of 99 initially successful DC shocks, requiring repeat shocks in 2 cases. Sinus bradycardia (n = 18) or high degree atrioventricular block (n = 11) necessitated rate support pacing in 10 patients. Antiarrhythmic drugs did not prevent postshock tachycardias, but facilitated the development of bradycardias. In conclusion, reliable and continuous analysis of cardiac rhythm after discharge is mandatory to enable automatic devices to correct unsuccessful discharges or recurring VT/VF. In addition, demand pacing capability is desirable to prevent severe bradycardia after DC shocks in patients receiving antiarrhythmic drugs.

Entities:  

Mesh:

Year:  1986        PMID: 3510522     DOI: 10.1016/0002-9149(86)90963-x

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  9 in total

1.  Electrocution-induced atrial fibrillation: a novel cause of a familiar arrhythmia.

Authors:  Alex Langford; Mark Dayer
Journal:  BMJ Case Rep       Date:  2012-04-04

2.  Regional cooling facilitates termination of spiral-wave reentry through unpinning of rotors in rabbit hearts.

Authors:  Masatoshi Yamazaki; Haruo Honjo; Takashi Ashihara; Masahide Harada; Ichiro Sakuma; Kazuo Nakazawa; Natalia Trayanova; Minoru Horie; Jérôme Kalifa; José Jalife; Kaichiro Kamiya; Itsuo Kodama
Journal:  Heart Rhythm       Date:  2011-08-10       Impact factor: 6.343

3.  Atria are more susceptible to electroporation than ventricles: implications for atrial stunning, shock-induced arrhythmia and defibrillation failure.

Authors:  Vadim V Fedorov; Geran Kostecki; Matt Hemphill; Igor R Efimov
Journal:  Heart Rhythm       Date:  2008-01-29       Impact factor: 6.343

4.  High-energy defibrillation increases the dispersion of regional ventricular repolarization.

Authors:  Yang Pang; Qi Jin; Ning Zhang; Shujing Ren; Tianyou Ling; Ying Chen; Gang Gu; Yongchu Shen; Liqun Wu
Journal:  J Interv Card Electrophysiol       Date:  2011-06-15       Impact factor: 1.900

5.  Differential effects of defibrillation on systemic and cardiac sympathetic activity.

Authors:  F Bode; U Wiegand; W Raasch; G Richardt; J Potratz
Journal:  Heart       Date:  1998-06       Impact factor: 5.994

6.  Transient local injury current in right ventricular electrogram after implantable cardioverter-defibrillator shock predicts heart failure progression.

Authors:  Larisa G Tereshchenko; Mitchell N Faddis; Barry J Fetics; Karl E Zelik; Igor R Efimov; Ronald D Berger
Journal:  J Am Coll Cardiol       Date:  2009-08-25       Impact factor: 24.094

Review 7.  Paediatric cardiac catheterization: innovations.

Authors:  J J Javorski; D D Hansen; P C Laussen; M L Fox; J Lavoie; F A Burrows
Journal:  Can J Anaesth       Date:  1995-04       Impact factor: 5.063

8.  Prolonged asystole following direct-current cardioversion for atrial flutter.

Authors:  R McMullan; D R Morgan; D B O'Keeffe; B Silke
Journal:  Ulster Med J       Date:  2001-11

9.  Impact of Postshock Transcutaneous Pacing on Chest Compression Quality during Resuscitation: A Simulation-Based Pilot Study.

Authors:  Wojciech Telec; Tomasz Kłosiewicz; Radosław Zalewski; Julia Żukowska-Karolak; Artur Baszko; Mateusz Puślecki
Journal:  Emerg Med Int       Date:  2021-04-22       Impact factor: 1.112

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.