Literature DB >> 35093548

Head-to-Head Comparison of Kinematic Alignment Versus Mechanical Alignment for Total Knee Arthroplasty.

Ameer M Elbuluk1, Seth A Jerabek1, Vincentius J Suhardi1, Peter K Sculco1, Michael P Ast1, Jonathan M Vigdorchik1.   

Abstract

BACKGROUND: Seeing as there are many alignment strategies for total knee arthroplasty (TKA), we need to determine differences between them in a rigorous scientific way. Therefore, we sought to compare perioperative and postoperative functional outcomes in patients undergoing TKA for varus osteoarthritis with a mechanical alignment target vs a kinematic alignment target, both executed with the same implant and same technological guidance.
METHODS: One hundred consecutive patients who underwent TKA using a mechanical alignment technique were 1:1 matched to 100 patients who underwent TKA using a kinematic alignment (KA) technique, using the same implant and robotic technology. Patient-reported outcomes were measured postoperatively at 1 and 2 years. Power analysis revealed 94 patients to detect a significant difference.
RESULTS: Mean Visual Analog Scale scores were higher in the mechanical alignment group during the first 6 weeks (P = .04), but statistically similar at 1 year. Six-week Veterans RAND 12 Item Health Survey mental and physical components were statistically similar (P = .1). Patients did not differ in 6-week or 1-year knee range of motion (P > .43). Knee Injury and Osteoarthritis Outcome Score Joint Replacement was significantly better in the KA group at 6 weeks, 1 year, and 2 years (P = .09). Forgotten Joint Score at 1 and 2 years postoperatively were significantly higher in the KA group (P < .001).
CONCLUSION: Patients undergoing TKA with KA experienced less pain in 6 weeks after surgery, and higher Forgotten Joint Scores at 1 and 2 years postoperatively. Alternative TKA alignment and balancing strategies should be considered to increase patient satisfaction.
Copyright © 2022 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  alignment; kinematic alignment; mechanical alignment; patient-reported outcomes; robotic-assisted surgery; total knee arthroplasty

Mesh:

Year:  2022        PMID: 35093548     DOI: 10.1016/j.arth.2022.01.052

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.435


  3 in total

1.  Mechanically aligned total knee arthroplasty with the extension-first technique does not equally restore neutral knee alignment in all preoperative knee phenotypes.

Authors:  Nina Hörlesberger; Carina Zinggl; Maria Anna Smolle; Lukas Leitner; Birgit Lohberger; Andreas Leithner; Patrick Sadoghi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-09-10       Impact factor: 4.114

2.  Use the Right Looking Glass When You Do Caliper-verified Kinematically Aligned TKA!

Authors:  Stephen M Howell
Journal:  Arthroplast Today       Date:  2022-05-10

3.  A Surgeon That Switched to Unrestricted Kinematic Alignment with Manual Instruments Has a Short Learning Curve and Comparable Resection Accuracy and Outcomes to Those of an Experienced Surgeon.

Authors:  Alexander J Nedopil; Anand Dhaliwal; Stephen M Howell; Maury L Hull
Journal:  J Pers Med       Date:  2022-07-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.