Literature DB >> 35084612

Outcomes of Ahmed glaucoma valve implantation and risk factors for graft failure in eyes with Descemet's stripping endothelial keratoplasty.

Mayank Rai1,2, Ashik Mohamed3, Sunita Chaurasia4, Sirisha Senthil5.   

Abstract

PURPOSE: The aim of this study was to assess the efficacy of Ahmed glaucoma valve (AGV) in eyes with Descemet's stripping endothelial keratoplasty (DSEK) and glaucoma and evaluate the risk factors for failure.
METHODS: Retrospective interventional study included 27 eyes (27 subjects) that underwent AGV implantation following DSEK. The main outcome measure was AGV success, defined as IOP between 6 and 21 mmHg with or without topical antiglaucoma medications (AGMs). Secondary outcome measure was graft survival. Graft failure was defined as corneal edema for ≥ 1 month or irreversible graft opacity requiring intervention.
RESULTS: Eighteen eyes (66.7%) had anterior chamber tube and 9 eyes (33.3%) had sulcus tube placement. Median follow-up was 1.2 years (interquartile range, IQR, 0.5-2.5 years). Following AGV implantation, the median IOP decreased significantly (p < 0.0001), median number of AGMs reduced significantly (p < 0.001) and median visual acuity was maintained (p = 0.76). Cumulative success probability of AGV was 75.8 ± 10.6% at 1 year, and 75.8 ± 10.6% at 2 years. For 24 clear grafts before AGV, estimates of success post-AGV were 100% at 1 year, 77.8 ± 10% at 2 years and 51.9 ± 16.4% at 3 years. Postoperative tube intervention was a borderline significant risk factor for graft failure (p = 0.05) with hazards ratio of 7.2; however, tube location was not associated with failure.
CONCLUSIONS: AGV can be considered an effective surgical option for IOP control in eyes with DSEK and glaucoma. However, high risk of long-term graft failure in these eyes needs to be considered specially those eyes needing tube intervention.
© 2022. The Author(s), under exclusive licence to Springer Nature B.V.

Entities:  

Keywords:  AGV; DSEK; Glaucoma implant; Graft failure

Mesh:

Year:  2022        PMID: 35084612     DOI: 10.1007/s10792-022-02231-7

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.029


  2 in total

1.  Increased Rates of Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) Graft Failure and Dislocation in Glaucomatous Eyes with Aqueous Shunts.

Authors:  Francis Char Decroos; Derek W Delmonte; Jessica H Chow; Sandra S Stinnett; Terry Kim; Alan N Carlson; Natalie A Afshari
Journal:  J Ophthalmic Vis Res       Date:  2012-07

2.  Distinctive and pervasive alterations in aqueous humor protein composition following different types of glaucoma surgery.

Authors:  Cyril Rosenfeld; Marianne O Price; Xianyin Lai; Frank A Witzmann; Francis W Price
Journal:  Mol Vis       Date:  2015-08-25       Impact factor: 2.367

  2 in total