| Literature DB >> 35082392 |
Ryan S Meshkin1, Grayson W Armstrong1, Nathan E Hall1, Elizabeth J Rossin1, Maggie B Hymowitz2, Alice C Lorch3.
Abstract
BACKGROUND: To study the utility of a teleophthalmology program to diagnose and triage common ophthalmic complaints presenting to an ophthalmic emergency room.Entities:
Year: 2022 PMID: 35082392 PMCID: PMC8790545 DOI: 10.1038/s41433-022-01940-8
Source DB: PubMed Journal: Eye (Lond) ISSN: 0950-222X Impact factor: 4.456
Fig. 1Smartphone anterior segment photo protocol.
iPhone photographs were taken using this template, with a full face image, image of eyes in primary gaze, and images of individual eyes in cardinal gazes.
Telemedical evaluation data stratified by complaint.
| Parameters | Overall ( | Eye Redness ( | Eye Pain ( | Blurred Vision ( | Eyelid Complaint ( | |
|---|---|---|---|---|---|---|
| Virtual evaluation parameters | ||||||
| Triage sensitivity (CI) | 0.71 (0.61–0.81) | 0.68 (0.50–0.86) | 0.58 (0.41–0.74) | 0.73 (0.60–0.86) | 0.67 (0.43–0.91) | |
| Triage specificity (CI) | 0.92 (0.86–0.98) | 0.93 (0.84–1.0) | 0.91 (0.80–1.0) | 0.91 (0.80–1.0) | 0.96 (0.89–1.0) | |
| Diagnostic accuracy | 113/220 (51.0%) | 32/54 (59.3%) | 27/56 (48.2%) | 30/68 (44.1%) | 24/42 (57.1%) | 0.31 |
| Mean confidence level ± SD | 5.6 ± 1.8 | 6.1 ± 1.6 | 5.4 ± 1.9 | 5.0 ± 1.7 | 6.0 ± 1.8 | 0.012 |
| Range | 1.0–9.7 | 2.3–9.7 | 1.0–9.3 | 1.0–9.0 | 2.3–9.3 | |
| Mean conf. level (Correct Dx) | 6.6 ± 1.6 | 6.8 ± 1.5 | 6.3 ± 1.7 | 6.1 ± 1.5 | 7.0 ± 1.5 | 0.13 |
| Mean conf. level (Incorrect Dx) | 4.5 ± 1.4 | 5.0 ± 1.1 | 4.5 ± 1.6 | 4.2 ± 1.3 | 4.6 ± 1.1 | 0.28 |
| “Urgent” triage (in-person) | 118/220 (54.0%) | 25/54 (46.3%) | 33/56 (58.9%) | 45/68 (66.2%) | 15/42 (35.7%) | 0.009 |
| “Urgent” triage (virtual) | 86/220 (39.1%) | 19/54 (35.2%) | 21/56 (37.5%) | 35/68 (51.5%) | 11/42 (26.2%) | 0.052 |
Telemedical evaluation data stratified by in-person triage status.
| Parameters | Overall ( | Non-urgent ( | Urgent ( | |
|---|---|---|---|---|
| Virtual evaluation parameters | ||||
| Mean confidence level ± SD | 5.6 ± 1.8 | 5.9 ± 1.8 | 5.3 ± 1.7 | 0.018 |
| Range | 1.0–9.7 | 1.7–9.7 | 1.0–9.0 | |
| Mean conf. level (Correct Triage) | 5.6 ± 1.8 | 5.9 ± 1.9 | 5.2 ± 1.7 | 0.012 |
| Mean conf. level (Incorrect Triage) | 5.6 ± 1.7 | 5.5 ± 1.8 | 5.6 ± 1.7 | 0.76 |
| Diagnostic accuracy | 113/220 (51.4%) | 60/102 (58.8%) | 53/118 (44.9%) | 0.054 |
Demographic data stratified by complaint.
| Parameters | Overall | Eye redness | Eye pain | Blurred vision | Eyelid complaint | |
|---|---|---|---|---|---|---|
| Demographics | ||||||
| Eyes | 220 | 54 | 56 | 68 | 42 | |
| Female sex, | 121 (55) | 29 (54) | 30 (54) | 37 (54) | 25 (60) | 0.93 |
| Mean age ± SD | 56.5 ± 17.9 | 53.9 ± 18.5 | 55.2 ± 17.3 | 58.3 ± 17.5 | 58.7 ± 18.6 | 0.46 |
| Range | 24–89 | 25–88 | 24–84 | 24–89 | 24–88 | |
| Presenting from PCP (%) | 50/220 (23) | 10/54 (19) | 13/56 (23) | 16/68 (24) | 11/42 (26) | 0.83 |
Adjusted telemedical sensitivity & specificity.
| Parameters | Overall ( | Eye redness ( | Eye pain ( | Blurred vision ( | Eyelid complaint ( |
|---|---|---|---|---|---|
| Low diagnostic confidence adjustment | |||||
| Triage sensitivity (CI) | 0.76 (0.67–0.85) | 0.68 (0.50–0.86) | 0.67 (0.51–0.83) | 0.78 (0.66–0.90) | 0.73 (0.51–0.96) |
| Triage specificity (CI) | 0.80 (0.71–0.89) | 0.90 (0.79–1.0) | 0.78 (0.80–1.0) | 0.78 (0.61–0.95) | 0.93 (0.83–1.0) |
| Triage disagreement adjustment | |||||
| Triage sensitivity (CI) | 0.79 (0.69–0.88) | 0.80 (0.64–0.96) | 0.73 (0.58–0.88) | 0.82 (0.71–0.93) | 0.80 (0.60–1.00) |
| Triage specificity (CI) | 0.92 (0.86–0.98) | 0.93 (0.84–1.00) | 0.91 (0.80–1.00) | 0.91 (0.80–1.00) | 0.96 (0.89–1.00) |
| Combined overall adjustment | |||||
| Triage sensitivity (CI) | 0.84 (0.75–0.92) | 0.80 (0.64–0.96) | 0.82 (0.69–0.95) | 0.87 (0.77–0.97) | 0.87 (0.69–1.00) |
| Triage specificity (CI) | 0.80 (0.71–0.89) | 0.90 (0.79–1.00) | 0.78 (0.61–0.95) | 0.78 (0.61–0.95) | 0.93 (0.83–1.00) |